Literature DB >> 17278141

Murine model of prosthesis failure for the long-term study of aseptic loosening.

Shang-You Yang1, Haiying Yu, Weiming Gong, Bin Wu, Lois Mayton, Richard Costello, Paul H Wooley.   

Abstract

We examined a novel mouse model of wear debris-induced prosthesis instability and osteolysis, and its application for the evaluation of therapy. A stainless steel or titanium-alloy pin was implanted into the proximal tibia to form a contiguous surface with the articular cartilage. In some mice, titanium particles were injected into the tibial canal during the surgery, followed by monthly intraarticular injection. MicroCT scans revealed that the implants without particle challenge were stable without bone mineral density changes for 6 months. Histological analysis showed new bone formation around the implant at 6 weeks postsurgery. Periprosthetic soft tissue with inflammatory cells was a ubiquitous finding at the interface between the implant and surrounding bone in samples exposed to titanium particles, and expression of IL-1beta, TNFalpha, and CD68 was common in these joints. Pullout tests indicated that an average 5N load was required to pull out stable implants from surrounding bone. However, particle stimulation dramatically reduced the pullout force to less than 0.4 N. The feasibility of in vivo gene transfer on this model was confirmed by X-gal staining of synovial membrane and periprosthetic tissue after injection of AAV-LacZ in the prosthetic joint. This murine model of weight-bearing knee prosthesis provides an economical, reproducible, and easily obtained means to study joint arthroplasty failure. The ability to evaluate the biomechanical properties of the prosthetic joint, in addition to histological and biochemical examination, results in a useful model to investigate many of the properties of prosthetic joint components during the response to debris-associated osteolysis. (c) 2007 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17278141     DOI: 10.1002/jor.20342

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  27 in total

1.  Comparison of the cytotoxic and inflammatory responses of titanium particles with different methods for endotoxin removal in RAW264.7 macrophages.

Authors:  Huifeng Ding; Zhenan Zhu; Tingting Tang; Degang Yu; Bo Yu; Kerong Dai
Journal:  J Mater Sci Mater Med       Date:  2012-02-23       Impact factor: 3.896

2.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

3.  The effect of osteoprotegerin gene modification on wear debris-induced osteolysis in a murine model of knee prosthesis failure.

Authors:  Tao Zhang; Haiying Yu; Weiming Gong; Laibo Zhang; Tanghong Jia; Paul H Wooley; Shang-You Yang
Journal:  Biomaterials       Date:  2009-08-07       Impact factor: 12.479

Review 4.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

Review 5.  Contributions of human tissue analysis to understanding the mechanisms of loosening and osteolysis in total hip replacement.

Authors:  Jiri Gallo; Jana Vaculova; Stuart B Goodman; Yrjö T Konttinen; Jacob P Thyssen
Journal:  Acta Biomater       Date:  2014-02-10       Impact factor: 8.947

6.  Interleukin-1 receptor-associated kinase-4 (IRAK4) promotes inflammatory osteolysis by activating osteoclasts and inhibiting formation of foreign body giant cells.

Authors:  Eri Katsuyama; Hiroya Miyamoto; Tami Kobayashi; Yuiko Sato; Wu Hao; Hiroya Kanagawa; Atsuhiro Fujie; Toshimi Tando; Ryuichi Watanabe; Mayu Morita; Kana Miyamoto; Yasuo Niki; Hideo Morioka; Morio Matsumoto; Yoshiaki Toyama; Takeshi Miyamoto
Journal:  J Biol Chem       Date:  2014-11-17       Impact factor: 5.157

7.  Macromolecular prodrug of dexamethasone prevents particle-induced peri-implant osteolysis with reduced systemic side effects.

Authors:  Ke Ren; Anand Dusad; Fang Yuan; Hongjiang Yuan; P Edward Purdue; Edward V Fehringer; Kevin L Garvin; Steven R Goldring; Dong Wang
Journal:  J Control Release       Date:  2013-12-08       Impact factor: 9.776

8.  Particulate and ion forms of cobalt-chromium challenged preosteoblasts promote osteoclastogenesis and osteolysis in a murine model of prosthesis failure.

Authors:  Shuye Yang; Kai Zhang; Jianhao Jiang; Bonface James; Shang-You Yang
Journal:  J Biomed Mater Res A       Date:  2018-10-25       Impact factor: 4.396

9.  Antioxidant impregnated ultra-high molecular weight polyethylene wear debris particles display increased bone remodeling and a superior osteogenic:osteolytic profile vs. conventional UHMWPE particles in a murine calvaria model.

Authors:  Yu Chen; Nadim J Hallab; Yen-Shuo Liao; Venkat Narayan; Edward M Schwarz; Chao Xie
Journal:  J Orthop Res       Date:  2015-11-23       Impact factor: 3.494

10.  Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

Authors:  Roberto J Fajardo; Esther Cory; Nipun D Patel; Ara Nazarian; Andres Laib; Rajaram K Manoharan; James E Schmitz; Jeremy M DeSilva; Laura M MacLatchy; Brian D Snyder; Mary L Bouxsein
Journal:  Bone       Date:  2008-09-10       Impact factor: 4.398

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.