Literature DB >> 1727405

A 5-y follow-up of the radiation exposure to in-room personnel during cardiac catheterization.

L Renaud1.   

Abstract

This study documents the radiation doses received by all in-room personnel of three cardiac catheterization laboratories where more than 15,000 cardiac procedures have been performed over a 5-y period. It is shown that all in-room personnel was exposed to a body dose equivalent well below any regulatory limits. However, some workers may have exceeded the occupational 150 mSv y-1 recommended limit for the lens of the eye. The physicians-in-training and the staff physicians are the two groups more likely to reach this limit. It is also demonstrated that a low correlation exists between the annual number of procedures and the annual head dose equivalent of a physician, but more variation is likely to originate from his/her working attitude and techniques. The mean dose equivalent at the collar level of the physicians is estimated to be 0.04 +/- 0.02 mSv per procedure.

Mesh:

Year:  1992        PMID: 1727405     DOI: 10.1097/00004032-199201000-00002

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  11 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Sex proportion of offspring and exposure to radiation in male invasive cardiologists.

Authors:  James W Choi; Praveen Mehrotra; Lee A Macdonald; Lloyd W Klein; Norm M Linsky; Anne M Smith; Mark J Ricciardi
Journal:  Proc (Bayl Univ Med Cent)       Date:  2007-07

Review 3.  Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review.

Authors:  Kwang Pyo Kim; Donald L Miller
Journal:  Radiat Prot Dosimetry       Date:  2009-03-27       Impact factor: 0.972

4.  Radiation exposure benefit of a lead cap in invasive cardiology.

Authors:  E Kuon; J Birkel; M Schmitt; J B Dahm
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

5.  Acousto-Optic Catheter Tracking Sensor for Interventional MRI Procedures.

Authors:  Yusuf Samet Yaras; Sarp Satir; Cagla Ozsoy; Rajiv Ramasawmy; Adrienne E Campbell-Washburn; Robert J Lederman; Ozgur Kocaturk; F Levent Degertekin
Journal:  IEEE Trans Biomed Eng       Date:  2018-09-05       Impact factor: 4.538

6.  Radiation Protection Knowledge, Attitude, and Practice (KAP) in Interventional Radiology.

Authors:  Fatemeh Shabani; Hadi Hasanzadeh; Alireza Emadi; Majid Mirmohammadkhani; Ahmad Bitarafan-Rajabi; Ali Abedelahi; Mitra Bokharaeian; Hamed Masoumi; Danial Seifi; Tahereh Khani; Mohamad Sanchooli; Shima Moshfegh; Abbas Ziari
Journal:  Oman Med J       Date:  2018-03

Review 7.  Cancer and non-cancer brain and eye effects of chronic low-dose ionizing radiation exposure.

Authors:  Eugenio Picano; Eliseo Vano; Luciano Domenici; Matteo Bottai; Isabelle Thierry-Chef
Journal:  BMC Cancer       Date:  2012-04-27       Impact factor: 4.430

Review 8.  The biological effects of diagnostic cardiac imaging on chronically exposed physicians: the importance of being non-ionizing.

Authors:  Maria Grazia Andreassi
Journal:  Cardiovasc Ultrasound       Date:  2004-11-22       Impact factor: 2.062

9.  Evaluation of the occupational doses of interventional radiologists.

Authors:  Gerritjan Kuipers; Xandra L Velders; Robbert J de Winter; Jim A Reekers; Jan J Piek
Journal:  Cardiovasc Intervent Radiol       Date:  2008-02-12       Impact factor: 2.740

10.  How to Achieve Near Zero Fluoroscopy During Radiofrequency Ablation of Atrial Fibrillation: A Strategy Used at Two Centers.

Authors:  Abdul Q Haji; Mohammed B Naji; Shakeel Jamal; Khalil Kanjwal
Journal:  Curr Cardiol Rev       Date:  2021
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.