Literature DB >> 1727113

Daily monitoring and correction of radiation field placement using a video-based portal imaging system: a pilot study.

A Ezz1, P Munro, A T Porter, J Battista, D A Jaffray, A Fenster, S Osborne.   

Abstract

We have developed a video-based portal imaging system for radiotherapy localization. The system can acquire high quality portal images automatically using short (1-3 monitor unit) irradiations and immediately display the images. The major advantage of the imaging system is that it can be used routinely to check and correct patient positioning before much of the daily irradiation has been delivered. The portal imaging system has been used in a pilot study to monitor five patients during each of their daily treatments. The study has shown that: (i) image quality is sufficiently high to detect discrepancies in field placement from that prescribed on the simulator film; (ii) discrepancies in field placement occur frequently; and, (iii) routine correction of patient and block positioning can reduce the size of these discrepancies. This is the first time that field placement in radiation therapy has been checked and corrected routinely, before the treatment irradiation. However, limitations in the size of the field of view and in the methods of extracting and presenting the geometric information to the users limits the clinical utility of the imaging system. Solutions to these limitations are currently under development.

Entities:  

Mesh:

Year:  1992        PMID: 1727113     DOI: 10.1016/0360-3016(92)90995-t

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

1.  Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours.

Authors:  X J Juan-Senabre; J López-Tarjuelo; A Conde-Moreno; A Santos-Serra; A L Sánchez-Iglesias; J D Quirós-Higueras; N de Marco Blancas; S Calzada-Feliu; C Ferrer-Albiach
Journal:  Clin Transl Oncol       Date:  2011-11       Impact factor: 3.405

2.  [Monitor assessment of digitalized and post-processed portal films compared to conventional films presented on a light box].

Authors:  S Wachter; N Gerstner; A Colotto; A Battmann; A Gahleitner; U Haverkamp; R Pötter
Journal:  Strahlenther Onkol       Date:  1998-11       Impact factor: 3.621

3.  Patient-specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy.

Authors:  Michael H Wittmer; Thomas M Pisansky; Jon J Kruse; Michael G Herman
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

4.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

5.  Theoretical foundation for real-time prostate localization using an inductively coupled transmitter and a superconducting quantum interference device (SQUID) magnetometer system.

Authors:  John E McGary
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

6.  A clinical evaluation of setup errors for a prostate immobilization system.

Authors:  J E McGary; W Grant
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

7.  A comparison of computer-controlled versus manual on-line patient setup adjustment.

Authors:  Kristy K Brock; Daniel L McShan; James M Balter
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.