Literature DB >> 17269247

Corneal hysteresis, resistance factor, topography, and pachymetry after corneal lamellar flap.

Damien Gatinel1, Slim Chaabouni, Pierre-Alexandre Adam, Jacques Munck, Michel Puech, Thanh Hoang-Xuan.   

Abstract

PURPOSE: To measure prospectively the early changes in corneal hysteresis, topography, and pachymetry after the creation of a stromal flap cut without laser photoablation.
METHODS: A 37-year-old man was referred for a bioptic procedure to correct for compound myopic astigmatism in the left eye. A 159-microm-thick 8x8.5-mm superior hinged flap was created with a mechanical microkeratome in the left cornea. Changes in the corneal hysteresis, corneal resistance factor, Goldmann correlated intraocular pressure (lOP), corneal compensated IOP, anterior and posterior topography, and optical and ultrasound pachymetry were monitored prospectively before and at 1 hour, 1 day, 5 days, and 25 days after flap creation. The right eye served as a control.
RESULTS: In the left eye, corneal hysteresis and corneal resistance factor decreased immediately after the flap cut and remained lower than preoperatively at 1 hour, 1 day, 5 days, and 25 days. Corneal compensated IOP varied significantly less than Goldmann correlated IOP in both eyes. Central flattening of the horizontal meridians was observed on the difference topography maps. The values of the left eye posterior best fit sphere increased after the flap cut. Increased central corneal thickness occurred immediately after the flap cut and decreased over time without returning to its preoperative value.
CONCLUSIONS: The creation of a stromal flap can modify the biomechanical properties of the cornea, including a reduction in corneal hysteresis. The topographic changes were consistent with previously reported cases of flap cut in normal corneas.

Entities:  

Mesh:

Year:  2007        PMID: 17269247     DOI: 10.3928/1081-597X-20070101-12

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  13 in total

1.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.

Authors:  Joo Young Shin; Jin Seok Choi; Joo Youn Oh; Mee Kum Kim; Jin Hak Lee; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2010-06-05

2.  Evaluation of corneal biomechanics in patients with keratectasia following LASIK using dynamic Scheimpflug analyzer.

Authors:  Ryotaro Ueki; Naoyuki Maeda; Mutsumi Fuchihata; Tomoko Asai; Shizuka Koh; Hisataka Fujimoto; Masafumi Uematsu; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2018-04-26       Impact factor: 2.447

3.  Corneal flap morphological analysis using anterior segment optical coherence tomography in laser in situ keratomileusis with femtosecond lasers versus mechanical microkeratome.

Authors:  Xiao-Xiao Zhang; Xing-Wu Zhong; Jun-Shu Wu; Zheng Wang; Ke-Ming Yu; Quan Liu; Bin Yang
Journal:  Int J Ophthalmol       Date:  2012-02-18       Impact factor: 1.779

4.  Differences in the early biomechanical effects of hyperopic and myopic laser in situ keratomileusis.

Authors:  Fabricio Witzel de Medeiros; Abhijit Sinha-Roy; Milton Ruiz Alves; Steven E Wilson; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2010-06       Impact factor: 3.351

5.  Corneal hysteresis in post-radial keratotomy primary open-angle glaucoma.

Authors:  Joshua S Hardin; Christopher I Lee; Lydia F Lane; Christian C Hester; R Grant Morshedi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-23       Impact factor: 3.117

6.  [Biomechanical condition of the cornea as a new indicator for pathological and structural changes].

Authors:  E Spörl; N Terai; M Haustein; A G Böhm; F Raiskup-Wolf; L E Pillunat
Journal:  Ophthalmologe       Date:  2009-06       Impact factor: 1.059

Review 7.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

8.  Quantitative assessment of the impact of biomedical image acquisition on the results obtained from image analysis and processing.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2014-07-04       Impact factor: 2.819

9.  Selected parameters of the corneal deformation in the Corvis tonometer.

Authors:  Robert Koprowski; Anita Lyssek-Boron; Anna Nowinska; Edward Wylegala; Henryk Kasprzak; Zygmunt Wrobel
Journal:  Biomed Eng Online       Date:  2014-05-03       Impact factor: 2.819

10.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer.

Authors:  Vanathi Murugesan; Ravi Bypareddy; Mahesh Kumar; Dada Tanuj; Panda Anita
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.