AIM: To assess and compare the flap morphology using anterior segment optical coherence tomography (AS-OCT) in laser in situ keratomileusis (LASIK) with Femto LDV femtosecond lasers versus Hansatome mechanical Microkeratome. METHODS: AS-OCT (Visante) was used to compare 1 month postoperatively the morphology of the flaps created with Femto LDV femtosecond lasers or Hansatome Microkeratome. The intended flap thickness was 110µm and 160µm respectively. The thickness of twenty-five points across each flap, which were 0mm, 1.5mm, 2.5mm, and 3.5mm to the corneal vertex on the horizontal, vertical, 45° and 135° meridian respectively, was evaluated. RESULTS: One month postoperative, the central flap thickness in the Femto LDV group was 107.43±4.70µm, while 125.90±17.50µm in the Hansatome group. The difference between the actual and the expected flap thickness was 5.61±3.84µm and 31.52±12.27µm, respectively. The Hansatome group had presented a statistically significant result (P<0.001). Flap morphology showed a more regular planar shape in the Femto LDV group and a meniscus shape in the Hansatome group. CONCLUSION: AS-OCT is a direct and fast procedure to assess the flap morphology. The morphology by AS-OCT showed that the flaps created with Femto LDV femtosecond laser were more accurate and regular than the flaps created with Hansatome microkeratome.
AIM: To assess and compare the flap morphology using anterior segment optical coherence tomography (AS-OCT) in laser in situ keratomileusis (LASIK) with Femto LDV femtosecond lasers versus Hansatome mechanical Microkeratome. METHODS: AS-OCT (Visante) was used to compare 1 month postoperatively the morphology of the flaps created with Femto LDV femtosecond lasers or Hansatome Microkeratome. The intended flap thickness was 110µm and 160µm respectively. The thickness of twenty-five points across each flap, which were 0mm, 1.5mm, 2.5mm, and 3.5mm to the corneal vertex on the horizontal, vertical, 45° and 135° meridian respectively, was evaluated. RESULTS: One month postoperative, the central flap thickness in the Femto LDV group was 107.43±4.70µm, while 125.90±17.50µm in the Hansatome group. The difference between the actual and the expected flap thickness was 5.61±3.84µm and 31.52±12.27µm, respectively. The Hansatome group had presented a statistically significant result (P<0.001). Flap morphology showed a more regular planar shape in the Femto LDV group and a meniscus shape in the Hansatome group. CONCLUSION: AS-OCT is a direct and fast procedure to assess the flap morphology. The morphology by AS-OCT showed that the flaps created with Femto LDV femtosecond laser were more accurate and regular than the flaps created with Hansatome microkeratome.
Entities:
Keywords:
AS-OCT; femtosecond laser; flap; laser in situ keratomileusis
Authors: Juhani Pietilä; Anne Huhtala; Markus Jääskeläinen; Jarmo Jylli; Petri Mäkinen; Hannu Uusitalo Journal: J Refract Surg Date: 2010-01-11 Impact factor: 3.573
Authors: Dan Z Reinstein; Sabong Srivannaboon; Timothy J Archer; Ronald H Silverman; Hugo Sutton; D Jackson Coleman Journal: J Refract Surg Date: 2006-11 Impact factor: 3.573
Authors: Samir I Sayegh; Ryan M Nolan; Woonggyu Jung; Jeehyun Kim; Daniel T McCormick; Eric J Chaney; Charles N Stewart; Stephen A Boppart Journal: Transl Vis Sci Technol Date: 2014-06-25 Impact factor: 3.283
Authors: Juan Gros-Otero; Isabel Rodríguez-Pérez; Miguel A Teus; Andreas Katsanos; Dimitrios G Mikropoulos; Montserrat García-González Journal: Ophthalmol Ther Date: 2022-03-09