Literature DB >> 17259415

Determining the rotational alignment of the tibial component at total knee replacement: a comparison of two techniques.

M Ikeuchi1, N Yamanaka, Y Okanoue, E Ueta, T Tani.   

Abstract

We prospectively assessed the benefits of using either a range-of-movement technique or an anatomical landmark method to determine the rotational alignment of the tibial component during total knee replacement. We analysed the cut proximal tibia intraoperatively, determining anteroposterior axes by the range-of-movement technique and comparing them with the anatomical anteroposterior axis. We found that the range-of-movement technique tended to leave the tibial component more internally rotated than when anatomical landmarks were used. In addition, it gave widely variable results (mean 7.5 degrees ; 2 degrees to 17 degrees ), determined to some extent by which posterior reference point was used. Because of the wide variability and the possibilities for error, we consider that it is inappropriate to use the range-of-movement technique as the sole method of determining alignment of the tibial component during total knee replacement.

Mesh:

Year:  2007        PMID: 17259415     DOI: 10.1302/0301-620X.89B1.17728

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  28 in total

1.  Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty.

Authors:  Stephen M Howell; Justin Chen; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-05       Impact factor: 4.342

2.  Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement.

Authors:  Namık Sahin; Teoman Atıcı; Ünal Kurtoğlu; Ali Turgut; Güven Ozkaya; Yüksel Ozkan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-03       Impact factor: 4.342

Review 3.  Rotational alignment of the tibial component in total knee arthroplasty.

Authors:  Pier Francesco Indelli; Angelo Graceffa; Massimiliano Marcucci; Andrea Baldini
Journal:  Ann Transl Med       Date:  2016-01

4.  Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Alfonso Noriega-Fernandez; Jose Manuel Fernandez-Carreira; Jose Manuel Fernandez-Simon; Jimena Llorens de los Rios
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

5.  Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error.

Authors:  Csaba Forster-Horvath; Valerie Kremo; Magdalena Müller-Gerbl; Andrej Maria Nowakowski
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

6.  Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver study.

Authors:  Roberto Rossi; Matteo Bruzzone; Davide Edoardo Bonasia; Antonio Marmotti; Filippo Castoldi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-01-08       Impact factor: 4.342

7.  Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis.

Authors:  Paolo Aglietti; Lorenzo Sensi; Pierluigi Cuomo; Antonio Ciardullo
Journal:  Clin Orthop Relat Res       Date:  2008-09-30       Impact factor: 4.176

8.  Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark.

Authors:  Andrea Baldini; Pier Francesco Indelli; Lapo DE Luca; Pierpaolo Cerulli Mariani; Massimiliano Marcucci
Journal:  Joints       Date:  2014-03-21

9.  Is there a gold standard for TKA tibial component rotational alignment?

Authors:  Erin E Hutter; Jeffrey F Granger; Matthew D Beal; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2013-02-08       Impact factor: 4.176

10.  Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty.

Authors:  William Pedraza; Johannes Beckmann; Constantin Mayer; Frieder Mauch; Jochen Huth; Raymond Best
Journal:  Int Orthop       Date:  2016-07-22       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.