Literature DB >> 17259414

Cemented versus hydroxyapatite fixation of the femoral component of the Freeman-Samuelson total knee replacement: a radiostereometric analysis.

J Uvehammer1, J Kärrholm, L Carlsson.   

Abstract

We have carried out a radiostereometric study of 50 patients (54 knees) with osteoarthritis of the knee who were randomly allocated to receive a cemented or a hydroxyapatite-coated femoral component for total knee replacement. The patients were also stratified to receive one of three types of articulating surface (standard, rotating platform, Freeman-Samuelson (FS)1000) all based on the Freeman-Samuelson design. The tibial components were cemented in all cases. Radiostereometry was performed post-operatively and at 3, 12 and 24 months. The analysis was restricted to rotation of the femoral component over time. After two years, rotation of the femoral components in the transverse, longitudinal and sagittal planes did not differ between the cemented and the hydroxyapatite-coated implants (p = 0.2 to 0.9). In total knee replacements with a rotating platform, the femoral component tended to tilt more posteriorly than in the other two designs, regardless of the choice of fixation (cemented or hydroxyapatite-coated, p = 0.04). The standard version of the femoral component, whether cemented or hydroxyapatite-coated, rotated more into valgus than was observed with the rotating-platform and FS1000 designs (p = 0.005). The increased constraint provided by the FS1000 component did not appear to have any adverse effect on fixation of the femoral component.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17259414     DOI: 10.1302/0301-620X.89B1.17974

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Cemented versus uncemented femoral components in total knee arthroplasty.

Authors:  Guillaume Demey; Elvire Servien; Sebastien Lustig; Tarik Aït Si Selmi; Philippe Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-12-15       Impact factor: 4.342

2.  No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.

Authors:  M G M Schotanus; P Pilot; B L Kaptein; W F Draijer; P B J Tilman; R Vos; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

3.  Uncemented or cemented femoral components work equally well in total knee arthroplasty.

Authors:  Anders Henricson; Radek Wojtowicz; Kjell G Nilsson; Sead Crnalic
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-25       Impact factor: 4.342

Review 4.  Hydroxyapatite (HA) coating appears to be of benefit for implant durability of tibial components in primary total knee arthroplasty.

Authors:  Jeffrey D Voigt; Michael Mosier
Journal:  Acta Orthop       Date:  2011-06-10       Impact factor: 3.717

Review 5.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

6.  CT-based micromotion analysis method can assess early implant migration and development of radiolucent lines in cemented glenoid components: a clinical feasibility study.

Authors:  Cyrus Brodén; Peter Reilly; Monica Khanna; Ravi Popat; Henrik Olivecrona; Dylan Griffiths; Olof Sköldenberg; Roger Emery
Journal:  Acta Orthop       Date:  2022-02-01       Impact factor: 3.717

  6 in total