Literature DB >> 17254730

Surface plasmon resonance immunosensor for human cardiac troponin T based on self-assembled monolayer.

Rosa Fireman Dutra1, Renata Kelly Mendes, Valdinete Lins da Silva, Lauro Tatsuo Kubota.   

Abstract

The cardiac troponin T (cTnT) is specific biomarker important for trials of acute myocardial infarctions (AMI). In this paper, a SPR sensor in real time to detect the biomarker was developed on a commercially available surface plasmon resonance AUTOLAB SPIRIT. The cTnT receptor molecule was covalently immobilized on a gold substrate via a self-assembled monolayer (SAM) of thiols by using cysteamine-coupling chemistry. This biosensor presented a linear response range for cTnT between 0.05 and 4.5 ng/mL (r=0.997, p<<0.01) with a good reproducibility (CV=4.4%). The effect of the cysteamine (CYS) concentrations on the SAM coated gold sensor was studied as a function of the amount of the immobilized cTnT monoclonal antibodies. Analysis using serum samples undiluted was carried out at room temperature showing a well agreement with the ECLIA methods and the sensor surface could be regenerated by using a solution of 1% (w/v) sodium dodecyl sulphate (SDS) without losing the sensor immunoreactivity. These studies open new perspectives of using SAM to develop regenerable immunosensor with a good reproducibility allowing its use in the clinical applications.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17254730     DOI: 10.1016/j.jpba.2006.12.013

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  8 in total

1.  Selective detection of bacteria in urine with a long-range surface plasmon waveguide biosensor.

Authors:  Paul Béland; Oleksiy Krupin; Pierre Berini
Journal:  Biomed Opt Express       Date:  2015-07-16       Impact factor: 3.732

2.  An electrochemical troponin T aptasensor based on the use of a macroporous gold nanostructure.

Authors:  Masoud Negahdary; Mostafa Behjati-Ardakani; Hossein Heli
Journal:  Mikrochim Acta       Date:  2019-05-27       Impact factor: 5.833

3.  Enhanced fluorescence anisotropy assay for human cardiac troponin I and T detection.

Authors:  Yanling Qiao; Hongmin Tang; Gerhard R Munske; Prashanta Dutta; Cornelius F Ivory; Wen-Ji Dong
Journal:  J Fluoresc       Date:  2011-06-07       Impact factor: 2.217

4.  Amperometric immunoassay for the carcinoembryonic antigen by using a peroxidase mimic consisting of palladium nanospheres functionalized with glutathione-capped gold nanoparticles on graphene oxide.

Authors:  Zhaoling Tan; Linlin Cao; Yuying Yang; Qin Yan; Qing Liu; Wen Zhang; Pingping Zhao; Yueyun Li; Daopeng Zhang
Journal:  Mikrochim Acta       Date:  2019-10-12       Impact factor: 5.833

Review 5.  Systems biology coupled with label-free high-throughput detection as a novel approach for diagnosis of chronic obstructive pulmonary disease.

Authors:  Joanna L Richens; Richard A Urbanowicz; Elizabeth A M Lunt; Rebecca Metcalf; Jonathan Corne; Lucy Fairclough; Paul O'Shea
Journal:  Respir Res       Date:  2009-04-22

6.  A nanostructured piezoelectric immunosensor for detection of human cardiac troponin T.

Authors:  Rosana A S Fonseca; Joilson Ramos-Jesus; Lauro T Kubota; Rosa F Dutra
Journal:  Sensors (Basel)       Date:  2011-11-16       Impact factor: 3.576

Review 7.  A Localized Surface Plasmon Resonance Sensor Using Double-Metal-Complex Nanostructures and a Review of Recent Approaches.

Authors:  Heesang Ahn; Hyerin Song; Jong-Ryul Choi; Kyujung Kim
Journal:  Sensors (Basel)       Date:  2017-12-31       Impact factor: 3.576

8.  Neutrophil Elastase Inhibitor Sivelestat Attenuates Myocardial Injury after Cardioplegic Arrest in Rat Hearts.

Authors:  Masahiro Fujii; Ryuzo Bessho
Journal:  Ann Thorac Cardiovasc Surg       Date:  2019-12-09       Impact factor: 1.520

  8 in total