Literature DB >> 17237682

Long-term follow-up of porous polyethylene spherical implants after enucleation and evisceration.

A Alwitry1, S West, J King, A J Foss, L C Abercrombie.   

Abstract

PURPOSE: To present long-term follow-up data on enucleations and eviscerations carried out with placement of spherical porous polyethylene implants.
METHODS: A retrospective, interventional, noncomparative case series of all patients undergoing primary evisceration or enucleation surgery from one teaching hospital ophthalmology department.
RESULTS: In total, 106 cases were identified. Eighty patients (75.5%) underwent enucleation (group A) and 26 (24.5%) underwent evisceration (group B). Patient demographics were similar in both groups. Mean implant size in group A was 20.5 mm and 17.2 mm in group B. Mean follow-up in group A was 40 months (range, 12 to 80 months). Mean follow-up in group B was 63 months (range, 12 to 72 months). Six cases (7.5%) in group A had complications (excluding implant exposure), whereas one case (3.8%) in group B had a complication (excluding implant exposure). Five patients (6.3%) in group A had implant exposure; 14 cases (53.8%) of implant exposure occurred in group B.
CONCLUSIONS: Our case series revealed a significantly higher incidence of implant exposure after evisceration than after enucleation. Our data suggest that enucleation should be the procedure of choice when removing an eye to minimize the risk of subsequent complications, particularly orbital implant exposure.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17237682     DOI: 10.1097/01.iop.0000249429.02757.6b

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  11 in total

1.  [Anterior surface breakdown following evisceration : "Classic", "scleral modification", and "scleral patch techniques"].

Authors:  J W C Vijlbrief; F Hafezi; D Paridaens
Journal:  Ophthalmologe       Date:  2010-03       Impact factor: 1.059

2.  [Porous orbital implants].

Authors:  B Cleres; H W Meyer-Rüsenberg
Journal:  Ophthalmologe       Date:  2014-06       Impact factor: 1.059

Review 3.  Integrated versus non-integrated orbital implants for treating anophthalmic sockets.

Authors:  Silvana Schellini; Regina El Dib; Leandro Re Silva; Joyce G Farat; Yuqing Zhang; Eliane C Jorge
Journal:  Cochrane Database Syst Rev       Date:  2016-11-07

4.  Surgical outcomes of acellular human dermal grafts for large conjunctiva defects in orbital implant insertion.

Authors:  Su-Kyung Jung; Ji-Sun Paik; Uk-Hyun Sonn; Suk-Woo Yang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-19       Impact factor: 3.117

5.  Effects and complications of placement of motility coupling post in porous polyethylene orbital implants.

Authors:  Hong-guang Cui; Rong-rong Hu; Hui-yan Li; Wei Han
Journal:  J Zhejiang Univ Sci B       Date:  2008-06       Impact factor: 3.066

6.  Long-term Surgical Outcomes of the Multi-purpose Conical Porous Synthetic Orbital Implant.

Authors:  Min-Ji Kang; Su-Kyung Jung; Won-Kyung Cho; Ji-Sun Paik; Suk-Woo Yang
Journal:  Korean J Ophthalmol       Date:  2015-09-22

7.  Long-term surgical outcomes of porous polyethylene orbital implants: a review of 314 cases.

Authors:  Su-Kyung Jung; Won-Kyung Cho; Ji-Sun Paik; Suk-Woo Yang
Journal:  Br J Ophthalmol       Date:  2011-11-17       Impact factor: 4.638

Review 8.  Current concepts of ocular adnexal surgery.

Authors:  Maria Borrelli; Gerd Geerling
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2013-02-27

9.  Effects on Periocular Tissues after Proton Beam Radiation Therapy for Intraocular Tumors.

Authors:  Youn Joo Choi; Tae Wan Kim; Suzy Kim; Hokyung Choung; Min Joung Lee; Namju Kim; Sang In Khwarg; Young Suk Yu
Journal:  J Korean Med Sci       Date:  2018-04-16       Impact factor: 2.153

10.  Nanoscale Topographical Characterization of Orbital Implant Materials.

Authors:  Marco Salerno; Andrea Reverberi; Francesco Baino
Journal:  Materials (Basel)       Date:  2018-04-24       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.