Literature DB >> 17236219

Vascular endothelial growth factor and dexamethasone release from nonfouling sensor coatings affect the foreign body response.

L W Norton1, H E Koschwanez, N A Wisniewski, B Klitzman, W M Reichert.   

Abstract

Vascular endothelial growth factor (VEGF) and dexamethasone (DX) release from hydrogel coatings were examined as a means to modify tissue inflammation and induce angiogenesis. Antibiofouling hydrogels for implantable glucose sensor coatings were prepared from 2-hydroxyethyl methacrylate, N-vinyl pyrrolidinone, and polyethylene glycol. Microdialysis sampling was used to test the effect of the hydrogel coating on glucose recovery. VEGF-releasing hydrogel-coated fibers increased vascularity and inflammation in the surrounding tissue after 2 weeks of implantation compared to hydrogel-coated fibers. DX-releasing hydrogel-coated fibers reduced inflammation compared to hydrogel-coated fibers and had reduced capsule vascularity compared to VEGF-releasing hydrogel-coated fibers. Hydrogels that released both VEGF and DX simultaneously also showed reduced inflammation at 2 weeks implantation; however, no enhanced vessel formation was observed indicating that the DX diminished the VEGF effect. At 6 weeks, there were no detectable differences between drug-releasing hydrogel-coated fibers and control fibers. From this study, hydrogel drug release affected initial events of the foreign body response with DX inhibiting VEGF, but once the drug depot was exhausted these effects disappeared. (c) 2007 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17236219      PMCID: PMC4070388          DOI: 10.1002/jbm.a.31088

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  55 in total

Review 1.  Migration of leukocytes across endothelium and beyond: molecules involved in the transmigration and fate of monocytes.

Authors:  W A Muller; G J Randolph
Journal:  J Leukoc Biol       Date:  1999-11       Impact factor: 4.962

Review 2.  Characterization of implantable biosensor membrane biofouling.

Authors:  N Wisniewski; F Moussy; W M Reichert
Journal:  Fresenius J Anal Chem       Date:  2000 Mar-Apr

Review 3.  Angiogenesis with biomaterial-based drug- and cell-delivery systems.

Authors:  Zarana S Patel; Antonios G Mikos
Journal:  J Biomater Sci Polym Ed       Date:  2004       Impact factor: 3.517

Review 4.  The role of continuous glucose sensors in diabetes care.

Authors:  Satish K Garg; Halsley K Hoff; H Peter Chase
Journal:  Endocrinol Metab Clin North Am       Date:  2004-03       Impact factor: 4.741

5.  Selective apoptosis of luteal endothelial cells in dexamethasone-treated rats leads to ischemic necrosis of luteal tissue.

Authors:  Francisco Gaytán; Concepción Morales; Carmen Bellido; José Eugenio Sánchez-Criado
Journal:  Biol Reprod       Date:  2002-01       Impact factor: 4.285

6.  Hyperstimulation and a gonadotropin-releasing hormone agonist modulate ovarian vascular permeability by altering expression of the tight junction protein claudin-5.

Authors:  Yoshimitsu Kitajima; Toshiaki Endo; Kunihiko Nagasawa; Kengo Manase; Hiroyuki Honnma; Tsuyoshi Baba; Takuhiro Hayashi; Hideki Chiba; Norimasa Sawada; Tsuyoshi Saito
Journal:  Endocrinology       Date:  2005-11-03       Impact factor: 4.736

7.  Five-year follow-up of a bipolar steroid-eluting ventricular pacing lead.

Authors:  B Schwaab; G Fröhlig; M Berg; H Schwerdt; H Schieffer
Journal:  Pacing Clin Electrophysiol       Date:  1999-08       Impact factor: 1.976

8.  VEGF164(165) as the pathological isoform: differential leukocyte and endothelial responses through VEGFR1 and VEGFR2.

Authors:  Tomohiko Usui; Susumu Ishida; Kenji Yamashiro; Yuichi Kaji; Vasiliki Poulaki; Johnny Moore; Tara Moore; Shiro Amano; Yoshitaka Horikawa; Darlene Dartt; Matthew Golding; David T Shima; Anthony P Adamis
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-02       Impact factor: 4.799

9.  Vascularizing the tissue surrounding a model biosensor: how localized is the effect of a subcutaneous infusion of vascular endothelial growth factor (VEGF)?

Authors:  W Kenneth Ward; Matthew J Quinn; Michael D Wood; Kenneth L Tiekotter; Sudha Pidikiti; Jennifer A Gallagher
Journal:  Biosens Bioelectron       Date:  2003-11-30       Impact factor: 10.618

10.  Selective ablation of immature blood vessels in established human tumors follows vascular endothelial growth factor withdrawal.

Authors:  L E Benjamin; D Golijanin; A Itin; D Pode; E Keshet
Journal:  J Clin Invest       Date:  1999-01       Impact factor: 14.808

View more
  50 in total

1.  Controllable mineral coatings on PCL scaffolds as carriers for growth factor release.

Authors:  Darilis Suárez-González; Kara Barnhart; Francesco Migneco; Colleen Flanagan; Scott J Hollister; William L Murphy
Journal:  Biomaterials       Date:  2011-10-19       Impact factor: 12.479

2.  Glucose sensor membranes for mitigating the foreign body response.

Authors:  Ahyeon Koh; Scott P Nichols; Mark H Schoenfisch
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

3.  The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants.

Authors:  Scott P Nichols; Ahyeon Koh; Nga L Brown; Michael B Rose; Bin Sun; Danielle L Slomberg; Daniel A Riccio; Bruce Klitzman; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2012-06-27       Impact factor: 12.479

4.  Toward an injectable continuous osmotic glucose sensor.

Authors:  Erik Johannessen; Olga Krushinitskaya; Andrey Sokolov; Häfliger Philipp; Arno Hoogerwerf; Christian Hinderling; Kari Kautio; Jaakko Lenkkeri; Esko Strömmer; Vasily Kondratyev; Tor Inge Tønnessen; Tom Eirik Mollnes; Henrik Jakobsen; Even Zimmer; Bengt Akselsen
Journal:  J Diabetes Sci Technol       Date:  2010-07-01

Review 5.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

6.  Device-based local delivery of siRNA against mammalian target of rapamycin (mTOR) in a murine subcutaneous implant model to inhibit fibrous encapsulation.

Authors:  Hironobu Takahashi; Yuwei Wang; David W Grainger
Journal:  J Control Release       Date:  2010-08-19       Impact factor: 9.776

7.  Prevascularized silicon membranes for the enhancement of transport to implanted medical devices.

Authors:  Kristan S Worthington; Luke A Wiley; Robert F Mullins; Budd A Tucker; Eric Nuxoll
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-08-28       Impact factor: 3.368

8.  Microsphere erosion in outer hydrogel membranes creating macroscopic porosity to counter biofouling-induced sensor degradation.

Authors:  S Vaddiraju; Y Wang; L Qiang; D J Burgess; F Papadimitrakopoulos
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

9.  Design Considerations for Silica-Particle-Doped Nitric-Oxide-Releasing Polyurethane Glucose Biosensor Membranes.

Authors:  Robert J Soto; Jonathon B Schofield; Shaylyn E Walter; Maggie J Malone-Povolny; Mark H Schoenfisch
Journal:  ACS Sens       Date:  2016-12-15       Impact factor: 7.711

Review 10.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.