Literature DB >> 22027297

Glucose sensor membranes for mitigating the foreign body response.

Ahyeon Koh1, Scott P Nichols, Mark H Schoenfisch.   

Abstract

Continuous glucose monitoring devices remain limited in their duration of use due to difficulties presented by the foreign body response (FBR), which impairs sensor functionality immediately following implantation via biofouling and leukocyte infiltration. The FBR persists through the life of the implant, culminating with fibrous encapsulation and isolation from normal tissue. These issues have led researchers to develop strategies to mitigate the FBR and improve tissue integration. Studies have often focused on abating the FBR using various outer coatings, thereby changing the chemical or physical characteristics of the sensor surface. While such strategies have led to some success, they have failed to fully integrate the sensor into surrounding tissue. To further address biocompatibility, researchers have designed coatings capable of actively releasing biological agents (e.g., vascular endothelial growth factor, dexamethasone, and nitric oxide) to direct the FBR to induce tissue integration. Active release approaches have proven promising and, when combined with biocompatible coating materials, may ultimately improve the in vivo lifetime of subcutaneous glucose biosensors. This article focuses on strategies currently under development for mitigating the FBR.
© 2011 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22027297      PMCID: PMC3208860          DOI: 10.1177/193229681100500505

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  85 in total

Review 1.  Glucocorticoid-regulated gene expression during cutaneous wound repair.

Authors:  H D Beer; R Fässler; S Werner
Journal:  Vitam Horm       Date:  2000       Impact factor: 3.421

2.  Surface tailoring for controlled protein adsorption: effect of topography at the nanometer scale and chemistry.

Authors:  Paul Roach; David Farrar; Carole C Perry
Journal:  J Am Chem Soc       Date:  2006-03-29       Impact factor: 15.419

Review 3.  Reducing implant-related infections: active release strategies.

Authors:  Evan M Hetrick; Mark H Schoenfisch
Journal:  Chem Soc Rev       Date:  2006-05-05       Impact factor: 54.564

4.  Inorganic/Organic Hybrid Silica Nanoparticles as a Nitric Oxide Delivery Scaffold.

Authors:  Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Mater       Date:  2008-01-01       Impact factor: 9.811

5.  Corticosteroids inhibit VEGF-induced vascular leakage in a rabbit model of blood-retinal and blood-aqueous barrier breakdown.

Authors:  Jeffrey L Edelman; David Lutz; Marisol R Castro
Journal:  Exp Eye Res       Date:  2005-02       Impact factor: 3.467

6.  Macroporous poly(L-lactide) scaffold 1. Preparation of a macroporous scaffold by liquid--liquid phase separation of a PLLA--dioxane--water system.

Authors:  Feng Jun Hua; Go Eun Kim; Jong Doo Lee; Yong Keun Son; Doo Sung Lee
Journal:  J Biomed Mater Res       Date:  2002

7.  Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors.

Authors:  C A Quinn; R E Connor; A Heller
Journal:  Biomaterials       Date:  1997-12       Impact factor: 12.479

8.  Bactericidal efficacy of nitric oxide-releasing silica nanoparticles.

Authors:  Evan M Hetrick; Jae Ho Shin; Nathan A Stasko; C Bryce Johnson; Daniel A Wespe; Ekhson Holmuhamedov; Mark H Schoenfisch
Journal:  ACS Nano       Date:  2008-02       Impact factor: 15.881

9.  Vascularizing the tissue surrounding a model biosensor: how localized is the effect of a subcutaneous infusion of vascular endothelial growth factor (VEGF)?

Authors:  W Kenneth Ward; Matthew J Quinn; Michael D Wood; Kenneth L Tiekotter; Sudha Pidikiti; Jennifer A Gallagher
Journal:  Biosens Bioelectron       Date:  2003-11-30       Impact factor: 10.618

10.  S-nitrosothiol-modified dendrimers as nitric oxide delivery vehicles.

Authors:  Nathan A Stasko; Thomas H Fischer; Mark H Schoenfisch
Journal:  Biomacromolecules       Date:  2008-02-05       Impact factor: 6.988

View more
  19 in total

1.  The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants.

Authors:  Scott P Nichols; Ahyeon Koh; Nga L Brown; Michael B Rose; Bin Sun; Danielle L Slomberg; Daniel A Riccio; Bruce Klitzman; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2012-06-27       Impact factor: 12.479

2.  Extended Nitric Oxide-Releasing Polyurethanes via S-Nitrosothiol-Modified Mesoporous Silica Nanoparticles.

Authors:  Maggie J Malone-Povolny; Mark H Schoenfisch
Journal:  ACS Appl Mater Interfaces       Date:  2019-03-19       Impact factor: 9.229

Review 3.  Nanotechnology in cell replacement therapies for type 1 diabetes.

Authors:  Alexander U Ernst; Daniel T Bowers; Long-Hai Wang; Kaavian Shariati; Mitchell D Plesser; Natalie K Brown; Tigran Mehrabyan; Minglin Ma
Journal:  Adv Drug Deliv Rev       Date:  2019-02-02       Impact factor: 15.470

4.  Nitric Oxide Release for Improving Performance of Implantable Chemical Sensors - A Review.

Authors:  Kyoung Ha Cha; Xuewei Wang; Mark E Meyerhoff
Journal:  Appl Mater Today       Date:  2017-11-09

5.  Factory-Calibrated Continuous Glucose Monitoring: How and Why It Works, and the Dangers of Reuse Beyond Approved Duration of Wear.

Authors:  Gregory P Forlenza; Taisa Kushner; Laurel H Messer; R Paul Wadwa; Sriram Sankaranarayanan
Journal:  Diabetes Technol Ther       Date:  2019-02-28       Impact factor: 6.118

6.  Microsphere erosion in outer hydrogel membranes creating macroscopic porosity to counter biofouling-induced sensor degradation.

Authors:  S Vaddiraju; Y Wang; L Qiang; D J Burgess; F Papadimitrakopoulos
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

7.  Design Considerations for Silica-Particle-Doped Nitric-Oxide-Releasing Polyurethane Glucose Biosensor Membranes.

Authors:  Robert J Soto; Jonathon B Schofield; Shaylyn E Walter; Maggie J Malone-Povolny; Mark H Schoenfisch
Journal:  ACS Sens       Date:  2016-12-15       Impact factor: 7.711

Review 8.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

9.  Cell based metabolic barriers to glucose diffusion: macrophages and continuous glucose monitoring.

Authors:  Ulrike Klueh; Jackman T Frailey; Yi Qiao; Omar Antar; Donald L Kreutzer
Journal:  Biomaterials       Date:  2014-01-22       Impact factor: 12.479

10.  Fabrication of nitric oxide-releasing porous polyurethane membranes-coated needle-type implantable glucose biosensors.

Authors:  Ahyeon Koh; Yuan Lu; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2013-10-08       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.