Literature DB >> 17225049

CT-based postimplant dosimetry of prostate brachytherapy: comparison of 1-mm and 5-mm section CT.

Osamu Tanaka1, Shinya Hayashi, Masayuki Kanematsu, Masayuki Matsuo, Masahiro Nakano, Sunaho Maeda, Takashi Deguchi, Hiroaki Hoshi.   

Abstract

PURPOSE: The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry.
MATERIALS AND METHODS: A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V(100) (percent of the prostate volume receiving at least the full prescribed dose), and prostate D(90) (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images.
RESULTS: The mean +/-1 SD postimplant pVol was 20.17 +/- 6.66 cc by 1-mm section CT and 22.24 +/- 8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P < 0.01). The mean postimplant prostate V(100) was 80.44% +/- 7.06% by 1-mm section CT and 77.33% +/- 10.22% by 5-mm section CT. The mean postimplant prostate D(90) was 83.28% +/- 10.81% by 1-mm section CT and 78.60% +/- 15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT.
CONCLUSION: Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17225049     DOI: 10.1007/s11604-006-0096-0

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  15 in total

Review 1.  The American Brachytherapy Society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis.

Authors:  S Nag; W Bice; K DeWyngaert; B Prestidge; R Stock; Y Yu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-01-01       Impact factor: 7.038

2.  Impact of prostate volume evaluation by different observers on CT-based post-implant dosimetry.

Authors:  Bashar Al-Qaisieh; Dan Ash; David M Bottomley; Brendan M Carey
Journal:  Radiother Oncol       Date:  2002-03       Impact factor: 6.280

3.  MR and CT image fusion for postimplant analysis in permanent prostate seed implants.

Authors:  Alfredo Polo; Federica Cattani; Andrea Vavassori; Daniela Origgi; Gaetano Villa; Hugo Marsiglia; Massimo Bellomi; Giampiero Tosi; Ottavio De Cobelli; Roberto Orecchia
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-12-01       Impact factor: 7.038

4.  Preliminary study of correction of original metal artifacts due to 1-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy.

Authors:  Yutaka Takahashi; Shinichiro Mori; Takuyo Kozuka; Kotaro Gomi; Takayuki Nose; Takatoshi Tahara; Masahiko Oguchi; Takashi Yamashita
Journal:  Radiat Med       Date:  2006-02

5.  Intraobserver and interobserver variability of MR imaging- and CT-derived prostate volumes after transperineal interstitial permanent prostate brachytherapy.

Authors:  D F Dubois; B R Prestidge; L A Hotchkiss; J J Prete; W S Bice
Journal:  Radiology       Date:  1998-06       Impact factor: 11.105

Review 6.  American Brachytherapy Society (ABS) recommendations for transperineal permanent brachytherapy of prostate cancer.

Authors:  S Nag; D Beyer; J Friedland; P Grimm; R Nath
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-01       Impact factor: 7.038

7.  The dependence of prostate postimplant dosimetric quality on CT volume determination.

Authors:  G S Merrick; W M Butler; A T Dorsey; J H Lief
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-15       Impact factor: 7.038

8.  A comprehensive review of CT-based dosimetry parameters and biochemical control in patients treated with permanent prostate brachytherapy.

Authors:  L Potters; Y Cao; E Calugaru; T Torre; P Fearn; X H Wang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-07-01       Impact factor: 7.038

9.  Definition of the prostate in CT and MRI: a multi-observer study.

Authors:  C Rasch; I Barillot; P Remeijer; A Touw; M van Herk; J V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-01-01       Impact factor: 7.038

10.  A comparison of CT scan to transrectal ultrasound-measured prostate volume in untreated prostate cancer.

Authors:  S Christopher Hoffelt; Lynn M Marshall; Mark Garzotto; Arthur Hung; John Holland; Tomasz M Beer
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-09-01       Impact factor: 7.038

View more
  1 in total

1.  A magnetic resonance-based seed localization method for I-125 prostate implants.

Authors:  Rena J Lee; Hyun Suk Suh; Kyung Ja Lee; Soome Lim; Yookyung Kim; Sungkyu Kim; Jinho Choi
Journal:  J Korean Med Sci       Date:  2007-09       Impact factor: 2.153

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.