Impact of prostate volume evaluation by different observers on CT-based post-implant dosimetry.

Bashar Al-Qaisieh1, Dan Ash, David M Bottomley, Brendan M Carey.   

Abstract

PURPOSE: An analysis of computed tomography (CT)-based dosimetry was performed to evaluate the variability of different observers' judgements in marking the prostate gland on CT films, and its effect on the parameters that characterise the prostate implantation quality. Accuracy of data entry by the first author in the process of dosimetry procedure has also been evaluated.
MATERIALS AND METHODS: Four observers were asked to evaluate the prostate volume on CT films for six different patients. Each observer repeated the evaluation six times. The sample of patients has a prostate volume in the range of 21.4-42.0 cc derived from transrectal ultrasound volume study. After an average period of 6 weeks of the I-125 implantation, all patients had CT scans. CT-based post-implant dosimetry was performed and the dose volume histograms DVHs were calculated to report the re-constructed prostate volume, Vp100, Vp150, Vp90 and D90. Comparison between the four observers' output was performed.
RESULTS: Comparison between the four observers shows that each observer has a different way of estimating the prostate on CT films. Observers' precision also varies according to the prostate volume and the image quality. This can cause a variation in the resulting D90 value by up to 50%. Analysis of data entry shows a high degree of accuracy. The error of digitizing the prostate is +/-0.19 cc. This is correlated to an error of +/-0.78 Gy of the D90.
CONCLUSION: The evaluation of prostate gland volume on CT films varies between different observers. This has an effect on the dosimetric indices that characterise the implant quality in particular the D90.

Entities:  

Mesh:

Year:  2002        PMID: 12175557     DOI: 10.1016/s0167-8140(01)00475-3

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  16 in total

1.  Automated computer-derived prostate volumes from MR imaging data: comparison with radiologist-derived MR imaging and pathologic specimen volumes.

Authors:  Julie C Bulman; Robert Toth; Amish D Patel; B Nicolas Bloch; Colm J McMahon; Long Ngo; Anant Madabhushi; Neil M Rofsky
Journal:  Radiology       Date:  2012-01       Impact factor: 11.105

2.  CT-based postimplant dosimetry of prostate brachytherapy: comparison of 1-mm and 5-mm section CT.

Authors:  Osamu Tanaka; Shinya Hayashi; Masayuki Kanematsu; Masayuki Matsuo; Masahiro Nakano; Sunaho Maeda; Takashi Deguchi; Hiroaki Hoshi
Journal:  Radiat Med       Date:  2007-01-25

3.  Preimplant factors affecting postimplant CT-determined prostate volume and the CT/TRUS volume ratio after transperineal interstitial prostate brachytherapy with 125I free seeds.

Authors:  Akitomo Sugawara; Jun Nakashima; Etsuo Kunieda; Hirohiko Nagata; Hirotaka Asakura; Mototsugu Oya; Naoyuki Shigematsu
Journal:  Radiat Oncol       Date:  2010-09-28       Impact factor: 3.481

4.  In vitro comparative study of vibro-acoustography versus pulse-echo ultrasound in imaging permanent prostate brachytherapy seeds.

Authors:  F G Mitri; B J Davis; J F Greenleaf; M Fatemi
Journal:  Ultrasonics       Date:  2008-04-29       Impact factor: 2.890

5.  Pulse sequence considerations for simulation and postimplant dosimetry of prostate brachytherapy.

Authors:  Jingfei Ma; Marinus A Moerland; Aradhana M Venkatesan; Tharakeswara K Bathala; Rajat J Kudchadker; Kristy K Brock; Steven J Frank
Journal:  Brachytherapy       Date:  2017-01-04       Impact factor: 2.362

6.  Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: a pilot ex vivo study.

Authors:  Mohammad Mehrmohammadi; Azra Alizad; Randall R Kinnick; Brian J Davis; Mostafa Fatemi
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

7.  Segmentation of pelvic structures for planning CT using a geometrical shape model tuned by a multi-scale edge detector.

Authors:  Fabio Martínez; Eduardo Romero; Gaël Dréan; Antoine Simon; Pascal Haigron; Renaud de Crevoisier; Oscar Acosta
Journal:  Phys Med Biol       Date:  2014-03-05       Impact factor: 3.609

8.  Comparison of MRI visualization between linearly placed iron-containing and non-iron-containing fiducial markers for prostate radiotherapy.

Authors:  Osamu Tanaka; Hisao Komeda; Masayoshi Tamaki; Kensaku Seike; Shota Fujimoto; Eiichi Yama; Shigeki Hirose; Masayuki Matsuo
Journal:  Br J Radiol       Date:  2017-11-28       Impact factor: 3.039

9.  Impact of learning curve and technical changes on dosimetry in low-dose brachytherapy for prostate cancer.

Authors:  E Le Fur; J P Malhaire; D Baverez; F Delage; M A Perrouin-Verbe; F Schlurmann; S Guerif; G Fournier; O Pradier; A Valeri
Journal:  Strahlenther Onkol       Date:  2012-11-11       Impact factor: 3.621

10.  Is it necessary to perform week three dosimetric analysis in low-dose-rate brachytherapy for prostate cancer when day 0 dosimetry is done? A quality assurance assessment.

Authors:  T Shaikh; N G Zaorsky; K Ruth; D Y Chen; R E Greenberg; J Li; K Crawford; E M Horwitz
Journal:  Brachytherapy       Date:  2014-11-07       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.