Literature DB >> 17224117

Identification of scanning slit-beam topographic parameters important in distinguishing normal from keratoconic corneal morphologic features.

Baris Sonmez1, Minh-Phuong Doan, D Rex Hamilton.   

Abstract

PURPOSE: To identify morphologic parameters obtained using scanning slit-beam topography that help distinguish normal from keratoconic corneal morphologic features.
DESIGN: Observational, retrospective, cross-sectional study.
METHODS: This retrospective review examined 207 normal eyes of patients undergoing an initial consultation for primary refractive surgery and 42 eyes with clinical keratoconus (KCN). The following parameters were examined and compared between the two groups: astigmatism, central corneal power, irregularity indices at 3 mm (II3) and 5 mm (II5), maximal posterior elevation (MPE) magnitude and location, thinnest optical pachymetry (TOP) magnitude and location, anterior elevation best-fit sphere (ABFS), posterior elevation best-fit sphere (PBFS), the ratio of ABFS to PBFS, the difference between average inferior and average superior K values at 3 mm and 5 mm in both keratometric (I-S K3 and I-S K5) and tangential (I-S T3 and I-S T5) topographic maps, and skewed radial axis at 3 mm (SRAX3) and 5 mm (SRAX5) of the keratometric topography map.
RESULTS: The II3, II5, MPE magnitude, TOP magnitude, ABFS, PBFS, ABFS-to-PBFS ratio, I-S K at both 3 mm and 5 mm, I-S T at both 3 and 5 mm, and SRAX at 3 mm and 5 mm values were significantly different among the two groups (P < .001). The least-correlated parameters were SRAX3, TOP magnitude, and II3 in the KCN group and I-S K3, amount of astigmatism and MPE magnitude in the normal group.
CONCLUSIONS: Parameters obtained using scanning slit-beam topography may allow improved differentiation of keratoconic from normal corneal shapes, especially when the poorly correlated intragroup parameters are used.

Entities:  

Mesh:

Year:  2006        PMID: 17224117     DOI: 10.1016/j.ajo.2006.11.044

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  14 in total

1.  Comparative analysis of the relationship between anterior and posterior corneal shape analyzed by Scheimpflug photography in normal and keratoconus eyes.

Authors:  Raúl Montalbán; Jorge L Alio; Jaime Javaloy; David P Piñero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-01-20       Impact factor: 3.117

2.  Comparison between corneal elevation maps using different reference surfaces with Scheimpflug-Placido topographer.

Authors:  Engy Mohamed Mostafa
Journal:  Int Ophthalmol       Date:  2016-07-28       Impact factor: 2.031

3.  Scanning-slit topography in patients with keratoconus.

Authors:  László Módis; Gábor Németh; Eszter Szalai; Zsuzsa Flaskó; Berthold Seitz
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

4.  Comparison of objective and subjective refractive surgery screening parameters between regular and high-resolution Scheimpflug imaging devices.

Authors:  J Bradley Randleman; Jihan Akhtar; Michael J Lynn; Renato Ambrósio; William J Dupps; Ronald R Krueger; Stephen D Klyce
Journal:  J Cataract Refract Surg       Date:  2014-12-20       Impact factor: 3.351

5.  Corneal elevation topography: best fit sphere, elevation distance, asphericity, toricity, and clinical implications.

Authors:  Damien Gatinel; Jacques Malet; Thanh Hoang-Xuan; Dimitri T Azar
Journal:  Cornea       Date:  2011-05       Impact factor: 2.651

6.  Visual rehabilitation and outcomes for ectasia after corneal refractive surgery.

Authors:  Maria A Woodward; J Bradley Randleman; Buddy Russell; Michael J Lynn; Michael A Ward; R Doyle Stulting
Journal:  J Cataract Refract Surg       Date:  2008-03       Impact factor: 3.351

7.  Evaluation of machine learning classifiers in keratoconus detection from orbscan II examinations.

Authors:  Murilo Barreto Souza; Fabricio Witzel Medeiros; Danilo Barreto Souza; Renato Garcia; Milton Ruiz Alves
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

8.  Effects of multicurve RGP contact lens use on topographic changes in keratoconus.

Authors:  Joon Seo Hwang; Jin Hak Lee; Won Ryang Wee; Mee Kum Kim
Journal:  Korean J Ophthalmol       Date:  2010-08-03

9.  Sensitivity and specificity of posterior and anterior corneal elevation measured by orbscan in diagnosis of clinical and subclinical keratoconus.

Authors:  Mohammad Reza Jafarinasab; Ebrahim Shirzadeh; Sepehr Feizi; Farid Karimian; Arash Akaberi; Hosein Hasanpour
Journal:  J Ophthalmic Vis Res       Date:  2015 Jan-Mar

10.  Revisiting keratoconus diagnosis and progression classification based on evaluation of corneal asymmetry indices, derived from Scheimpflug imaging in keratoconic and suspect cases.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-07-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.