Literature DB >> 21107250

Corneal elevation topography: best fit sphere, elevation distance, asphericity, toricity, and clinical implications.

Damien Gatinel1, Jacques Malet, Thanh Hoang-Xuan, Dimitri T Azar.   

Abstract

PURPOSE: To describe the effect of the corneal asphericity and toricity on the map patterns and best fit sphere (BFS) characteristics in elevation topography.
METHODS: The corneal surface was modeled as a biconic surface of principal radii and asphericity values of r1 and r2 and Q1 and Q2, respectively. The apex of the biconic surface corresponded to the origin of a polar coordinates system. Minimization of the squared residuals was used to calculate the values of the radii of the BFSs and apex distance (A-values: z distance between the corneal apex and the BFS) of the modeled corneal surface for various configurations relating to commonly clinically measured values of apical radius, asphericity, and toricity.
RESULTS: Increased apical radius of curvature and increased prolateness (negative asphericity) led to an increase in BFS radius but had opposite effects on the A-value. Increased prolateness resulted in increased BFS radius and A-value. Increasing toricity did not alter these findings. Color-plot elevation maps of the modeled corneal surface showed complete ridge patterns when toricity was increased and showed incomplete ridge and island patterns when prolateness was increased.
CONCLUSIONS: High A-values in patients with corneal astigmatism may result from steep apical curvature and/or high prolateness (negative asphericity). The BFS radius may help in distinguishing between these 2 causes of increased A-values. Increased prolateness and decreased apical radius of curvature (often seen in keratoconus) have opposite effects on the BFS radius but similar effects on the apex distance.

Entities:  

Mesh:

Year:  2011        PMID: 21107250      PMCID: PMC4142625          DOI: 10.1097/ICO.0b013e3181fb4fa7

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  58 in total

Review 1.  Orbscan computerized topography: attributes, applications, and limitations.

Authors:  Gerard Cairns; Charles N J McGhee
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

2.  The shape of the anterior and posterior surface of the aging human cornea.

Authors:  M Dubbelman; V A D P Sicam; G L Van der Heijde
Journal:  Vision Res       Date:  2005-11-02       Impact factor: 1.886

3.  The topography of the central and peripheral cornea.

Authors:  Scott A Read; Michael J Collins; Leo G Carney; Ross J Franklin
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-04       Impact factor: 4.799

4.  Ectasia following laser in situ keratomileusis.

Authors:  Edward J Holland
Journal:  J Cataract Refract Surg       Date:  2005-11       Impact factor: 3.351

5.  Keratoconus and corneal ectasia after LASIK.

Authors:  Perry S Binder; Richard L Lindstrom; R Doyle Stulting; Eric Donnenfeld; Helen Wu; Peter McDonnell; Yaron Rabinowitz
Journal:  J Cataract Refract Surg       Date:  2005-11       Impact factor: 3.351

6.  Optics of the average normal cornea from general and canonical representations of its surface topography.

Authors:  Rafael Navarro; Luis González; José L Hernández
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-02       Impact factor: 2.129

7.  Custom photorefractive keratectomy ablations for the correction of spherical and cylindrical refractive error and higher-order aberration.

Authors:  J Schwiegerling; R W Snyder
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1998-09       Impact factor: 2.129

8.  Model for nonectatic increase in posterior corneal elevation after ablative procedures.

Authors:  Deborah M Grzybowski; Cynthia J Roberts; Ashraf M Mahmoud; John S Chang
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

9.  Evaluation of Orbscan II corneal topography in individuals with myopia.

Authors:  Rui Hua Wei; Li Lim; Wing Kwong Chan; Donald T H Tan
Journal:  Ophthalmology       Date:  2006-02       Impact factor: 12.079

10.  KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus.

Authors:  Y S Rabinowitz; K Rasheed
Journal:  J Cataract Refract Surg       Date:  1999-10       Impact factor: 3.351

View more
  5 in total

Review 1.  Wound healing after keratorefractive surgery: review of biological and optical considerations.

Authors:  Dimitri T Azar; Jin-Hong Chang; Kyu Yeon Han
Journal:  Cornea       Date:  2012-11       Impact factor: 2.651

2.  Human rather than ape-like orbital morphology allows much greater lateral visual field expansion with eye abduction.

Authors:  Eric Denion; Martin Hitier; Eric Levieil; Frédéric Mouriaux
Journal:  Sci Rep       Date:  2015-07-20       Impact factor: 4.379

3.  Analysis of the viscoelastic properties of the human cornea using Scheimpflug imaging in inflation experiment of eye globes.

Authors:  Giuseppe Lombardo; Sebastiano Serrao; Marianna Rosati; Marco Lombardo
Journal:  PLoS One       Date:  2014-11-14       Impact factor: 3.240

4.  The Sclerotic Scatter Limbal Arc Is More Easily Elicited under Mesopic Rather Than Photopic Conditions.

Authors:  Eric Denion; Anne-Laure Lux; Frédéric Mouriaux; Guillaume Béraud
Journal:  PLoS One       Date:  2016-03-10       Impact factor: 3.240

5.  Anterior segment characteristics in normal and keratoconus eyes evaluated with a new type of swept-source optical coherence tomography.

Authors:  Kook Young Kim; Seongjun Lee; Young Joon Jeon; Ji Sang Min
Journal:  PLoS One       Date:  2022-09-01       Impact factor: 3.752

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.