Literature DB >> 17202625

Pixel-by-pixel deconvolution of bolus-tracking data: optimization and implementation.

S Sourbron1, M Dujardin, S Makkat, R Luypaert.   

Abstract

Quantification of haemodynamic parameters with a deconvolution analysis of bolus-tracking data is an ill-posed problem which requires regularization. In a previous study, simulated data without structural errors were used to validate two methods for a pixel-by-pixel analysis: standard-form Tikhonov regularization with either the L-curve criterion (LCC) or generalized cross validation (GCV) for selecting the regularization parameter. However, problems of image artefacts were reported when the methods were applied to patient data. The aim of this study was to investigate the nature of these problems in more detail and evaluate strategies of optimization for routine application in the clinic. In addition we investigated to which extent the calculation time of the algorithm can be minimized. In order to ensure that the conclusions are relevant for a larger range of clinical applications, we relied on patient data for evaluation of the algorithms. Simulated data were used to validate the conclusions in a more quantitative manner. We conclude that the reported problems with image quality can be removed by appropriate optimization of either LCC or GCV. In all examples this could be achieved with LCC without significant perturbation of the values in pixels where the regularization parameter was originally selected accurately. GCV could not be optimized for the renal data, and in the CT data only at the cost of image resolution. Using the implementations given, calculation times were sufficiently short for routine application in the clinic.

Entities:  

Mesh:

Year:  2006        PMID: 17202625     DOI: 10.1088/0031-9155/52/2/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

Review 1.  Is bone marrow edema syndrome a precursor of hip or knee osteonecrosis? Results of 49 patients and review of the literature.

Authors:  Tobias Geith; Ann-Cathrin Stellwag; Peter E Müller; Maximilian Reiser; Andrea Baur-Melnyk
Journal:  Diagn Interv Radiol       Date:  2020-07       Impact factor: 2.630

2.  Dose response of the intravascular contrast agent gadofosveset trisodium in MR perfusion imaging of the myocardium using a quantitative evaluation.

Authors:  Sebastian Niedermayer; Steven Sourbron; Maria Prompona; Clemens Cyran; Maximilian Reiser; Armin Huber
Journal:  Int J Cardiovasc Imaging       Date:  2013-06-06       Impact factor: 2.357

3.  Analysis Protocol for Dynamic Contrast Enhanced (DCE) MRI of Renal Perfusion and Filtration.

Authors:  Frank G Zöllner; Walter Dastrù; Pietro Irrera; Dario Livio Longo; Kevin M Bennett; Scott C Beeman; G Larry Bretthorst; Joel R Garbow
Journal:  Methods Mol Biol       Date:  2021

4.  UMMPerfusion: an open source software tool towards quantitative MRI perfusion analysis in clinical routine.

Authors:  Frank G Zöllner; Gerald Weisser; Marcel Reich; Sven Kaiser; Stefan O Schoenberg; Steven P Sourbron; Lothar R Schad
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

Review 5.  Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer.

Authors:  Michael Ingrisch; Steven Sourbron
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-04-06       Impact factor: 2.745

6.  Correlation analysis of dual-energy CT iodine maps with quantitative pulmonary perfusion MRI.

Authors:  Jan Hansmann; Paul Apfaltrer; Frank G Zoellner; Thomas Henzler; Mathias Meyer; Gerald Weisser; Stefan O Schoenberg; Ulrike I Attenberger
Journal:  World J Radiol       Date:  2013-05-28

7.  Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

Authors:  Marica Cutajar; David L Thomas; Patrick W Hales; T Banks; Christopher A Clark; Isky Gordon
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

8.  Detection of Local Recurrence with 3-Tesla MRI After Radical Prostatectomy: A Useful Method for Radiation Treatment Planning?

Authors:  Daniel Buergy; Metin Sertdemir; Anja Weidner; Mohamed Shelan; Frank Lohr; Frederik Wenz; Stefan O Schoenberg; Ulrike I Attenberger
Journal:  In Vivo       Date:  2018 Jan-Feb       Impact factor: 2.155

9.  Region of interest-based versus whole-lung segmentation-based approach for MR lung perfusion quantification in 2-year-old children after congenital diaphragmatic hernia repair.

Authors:  M Weis; V Sommer; F G Zöllner; C Hagelstein; K Zahn; T Schaible; S O Schoenberg; K W Neff
Journal:  Eur Radiol       Date:  2016-04-06       Impact factor: 5.315

10.  Comparison of myocardial perfusion estimates from dynamic contrast-enhanced magnetic resonance imaging with four quantitative analysis methods.

Authors:  Nathan A Pack; Edward V R DiBella
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.