Automated correction of unwanted phase jumps in reference signals which corrupt MRSI spectra after eddy current correction.

A W Simonetti1, W J Melssen, M van der Graaf, A Heerschap, L M C Buydens.   

Abstract

A commonly applied step in the postprocessing of gradient localized proton MR spectroscopy, is correction for eddy current effects using the water signal as a reference. However, this method can degrade some of the metabolite signals, in particular if applied on proton MR spectroscopic imaging data. This artifact arises from the water reference signal in the presence of a second signal which resonates close to the main water resonance. The interference of both resonances will introduce jumps in the phase of the reference time domain signal. Using this phase for eddy current correction will result in a ringing artifact in the frequency domain of the metabolite signal over the whole frequency range. We propose a moving window correction algorithm, which screens the phase of reference signals and removes phase jumps in time domain caused by interference of signals from multiple spin systems. The phase jumps may be abrupt or gradually distributed over several time data points. Because the correction algorithm only corrects time data points which contain phase jumps, the phase is minimally disrupted. Furthermore, the algorithm is automated for large datasets, correcting only those water reference signals which are corrupted. After correction of the corrupted reference signals, normal eddy current correction may be performed. The algorithm is compared with a method which uses a low-pass filter and tested on simulated data as well as on in vivo proton spectroscopic imaging data from a healthy volunteer and from patients with a brain tumor. Copyright 2002 Elsevier Science (USA)

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12482693     DOI: 10.1016/s1090-7807(02)00102-7

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  4 in total

1.  Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state.

Authors:  Xiang He; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

Review 2.  Proton MR spectroscopy of the brain at 3 T: an update.

Authors:  Alfonso Di Costanzo; Francesca Trojsi; Michela Tosetti; Timo Schirmer; Silke M Lechner; Teresa Popolizio; Tommaso Scarabino
Journal:  Eur Radiol       Date:  2007-01-18       Impact factor: 5.315

3.  Absolute choline tissue concentration mapping for prostate cancer localization and characterization using 3D 1 H MRSI without water-signal suppression.

Authors:  Nassim Tayari; Alan J Wright; Arend Heerschap
Journal:  Magn Reson Med       Date:  2021-09-23       Impact factor: 3.737

4.  Highly-accelerated quantitative 2D and 3D localized spectroscopy with linear algebraic modeling (SLAM) and sensitivity encoding.

Authors:  Yi Zhang; Refaat E Gabr; Jinyuan Zhou; Robert G Weiss; Paul A Bottomley
Journal:  J Magn Reson       Date:  2013-10-18       Impact factor: 2.229

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.