Literature DB >> 17190303

Load fatigue performance of a single-tooth implant abutment system: effect of diameter.

Christopher E Quek1, Keson B Tan, Jack I Nicholls.   

Abstract

PURPOSE: This study investigated the load fatigue performance of narrow-, regular-, and wide-diameter CeraOne (Nobel Biocare) single-tooth implants and abutments.
MATERIALS AND METHODS: Five samples of each implant-abutment combination in 3 different widths were tested at 3 applied screw torque levels (recommended torque, recommended torque +20%, and recommended torque -20%). A rotational load fatigue machine was used to apply a 21-N load, at an angle of 45 degrees to the long axis of the specimens. This loading produced an effective bending moment of 35 Ncm at the abutment-implant interface. An upper cyclic limit was set at 5 x 10(6) load cycles for all specimens.
RESULTS: Two-way analysis of variance revealed a significant difference between narrow-diameter and wide-diameter implant test groups but no significant difference between the 3 torque levels for each implant diameter. In the narrow-diameter group, 6 of the 15 specimens failed (5 abutment screw failures and 1 implant failure). In the regular-diameter group, 3 of the 15 specimens failed (2 implant failures and 1 abutment screw failure). There were no failures in the wide-diameter group. DISCUSSION: The results of this study indicate that the abutment screw is not the only potential failure location. The possibility of implant fracture clinically has been previously reported for prostheses supported by both single- and multiple-implant prostheses.
CONCLUSION: The wide-diameter CeraOne single-tooth implant system demonstrated superior load fatigue performance. For clinical situations with significant functional loading, the narrow-diameter implants would be at a greater risk of fatigue failure.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17190303

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  14 in total

Review 1.  Role of implant diameter on long-term survival of dental implants placed in posterior maxilla: a systematic review.

Authors:  Fawad Javed; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-11-01       Impact factor: 3.573

2.  A Simple and Cost Effective Method used for Removal of a Fractured Implant Abutment Screw: A Case Report.

Authors:  Parth Satwalekar; K Subash Chander; B Anantha Reddy; N Sandeep; N Sandeep; Tanushree Satwalekar
Journal:  J Int Oral Health       Date:  2013-10-26

3.  Biomechanical effects of the implant material and implant-abutment interface in immediately loaded small-diameter implants.

Authors:  Aaron Yu-Jen Wu; Heng-Li Huang; Jui-Ting Hsu; Winston Chee
Journal:  Clin Oral Investig       Date:  2013-09-03       Impact factor: 3.573

4.  Photoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wide.

Authors:  Marcelo Coelho Goiato; Alves Aldiéris Pesqueira; Daniela Micheline Dos Santos; Marcela Filié Haddad; Amália Moreno
Journal:  J Clin Diagn Res       Date:  2014-09-20

Review 5.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

6.  Bone loss around narrow implants versus standard diameter implants: Retrospective 2-years case-control study.

Authors:  José-Ramón Corcuera-Flores; Manuel Pérez-Fierro; Andrés Blanco-Carrión; Daniel Torres-Lagares; Lizett Castellanos-Cosano; Guillermo Machuca-Portillo
Journal:  J Clin Exp Dent       Date:  2020-01-01

7.  Narrow- versus mini-implants at crestal and subcrestal bone levels. Experimental study in beagle dogs at three months.

Authors:  José Luis Calvo-Guirado; Carlos Pérez-Albacete; Antonio Aguilar-Salvatierra; José E de Val Maté-Sánchez; Rafael A Delgado-Ruiz; Marcus Abboud; Eugenio Velasco; Gerardo Gómez-Moreno; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-12-11       Impact factor: 3.573

8.  Modified ridge splitting and bone expansion osteotomy for placement of dental implant in esthetic zone.

Authors:  Mayur S Khairnar; Darshana Khairnar; Kedar Bakshi
Journal:  Contemp Clin Dent       Date:  2014-01

9.  Narrow-diameter implants with conical connection for restoring the posterior edentulous region.

Authors:  In-Hee Woo; Ju-Won Kim; So-Young Kang; Young-Hee Kim; Byoung-Eun Yang
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-08-05

Review 10.  An Overview of the Mechanical Integrity of Dental Implants.

Authors:  Keren Shemtov-Yona; Daniel Rittel
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.