Literature DB >> 17167136

Colonoscopic withdrawal times and adenoma detection during screening colonoscopy.

Robert L Barclay1, Joseph J Vicari, Andrea S Doughty, John F Johanson, Roger L Greenlaw.   

Abstract

BACKGROUND: Colonoscopy is commonly used to screen for neoplasia. To assess the performance of screening colonoscopy in everyday practice, we conducted a study of the rates of detection of adenomas and the amount of time taken to withdraw the colonoscope among endoscopists in a large community-based practice.
METHODS: During a 15-month period, 12 experienced gastroenterologists performed 7882 colonoscopies, of which 2053 were screening examinations in subjects who had not previously undergone colonoscopy. We recorded the numbers, sizes, and histologic features of the neoplastic lesions detected during screening, as well as the duration of insertion and of withdrawal of the colonoscope during the procedure. We compared rates of detection of neoplastic lesions among gastroenterologists who had mean colonoscopic withdrawal times of less than 6 minutes with the rates of those who had mean withdrawal times of 6 minutes or more. According to experts, 6 minutes is the minimum length of time to allow adequate inspection during instrument withdrawal.
RESULTS: Neoplastic lesions (mostly adenomatous polyps) were detected in 23.5% of screened subjects. There were large differences among gastroenterologists in the rates of detection of adenomas (range of the mean number of lesions per subject screened, 0.10 to 1.05; range of the percentage of subjects with adenomas, 9.4 to 32.7%) and in their times of withdrawal of the colonoscope from the cecum to the anus (range, 3.1 to 16.8 minutes for procedures during which no polyps were removed). As compared with colonoscopists with mean withdrawal times of less than 6 minutes, those with mean withdrawal times of 6 minutes or more had higher rates of detection of any neoplasia (28.3% vs. 11.8%, P<0.001) and of advanced neoplasia (6.4% vs. 2.6%, P=0.005).
CONCLUSIONS: In this large community-based gastroenterology practice, we observed greater rates of detection of adenomas among endoscopists who had longer mean times for withdrawal of the colonoscope. The effect of variation in withdrawal times on lesion detection and the prevention of colorectal cancer in the context of widespread colonoscopic screening is not known. Ours was a preliminary study, so the generalizability and implications for clinical practice need to be determined by future studies. 2006 Massachusetts Medical Society

Entities:  

Mesh:

Year:  2006        PMID: 17167136     DOI: 10.1056/NEJMoa055498

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  329 in total

1.  Removal of infused water predominantly during insertion (water exchange) is consistently associated with an increase in adenoma detection rate - review of data in randomized controlled trials (RCTs) of water-related methods.

Authors:  Fw Leung; Jo Harker; Jw Leung; Rm Siao-Salera; Sk Mann; Fc Ramirez; S Friedland; A Amato; F Radaelli; S Paggi; V Terruzzi; Yh Hsieh
Journal:  J Interv Gastroenterol       Date:  2011-07-01

2.  Trainees' adenoma detection rate is higher if ≥ 10 minutes is spent on withdrawal during colonoscopy.

Authors:  Mark A Gromski; Christopher A Miller; Suck-Ho Lee; Eun Seo Park; Tae Hoon Lee; Sang-Heum Park; Il-Kwun Chung; Sun-Joo Kim; Young Hwangbo
Journal:  Surg Endosc       Date:  2011-11-16       Impact factor: 4.584

3.  The quality of screening colonoscopies in an office-based endoscopy clinic.

Authors:  Douglas Bair; Joe Pham; M Bianca Seaton; Naveen Arya; Michelle Pryce; Trevor L Seaton
Journal:  Can J Gastroenterol       Date:  2009-01       Impact factor: 3.522

4.  A pooled analysis of advanced colorectal neoplasia diagnoses after colonoscopic polypectomy.

Authors:  María Elena Martínez; John A Baron; David A Lieberman; Arthur Schatzkin; Elaine Lanza; Sidney J Winawer; Ann G Zauber; Ruiyun Jiang; Dennis J Ahnen; John H Bond; Timothy R Church; Douglas J Robertson; Stephanie A Smith-Warner; Elizabeth T Jacobs; David S Alberts; E Robert Greenberg
Journal:  Gastroenterology       Date:  2008-12-09       Impact factor: 22.682

5.  Physician characteristics associated with higher adenoma detection rate.

Authors:  Ateev Mehrotra; Michele Morris; Rebecca A Gourevitch; David S Carrell; Daniel A Leffler; Sherri Rose; Julia B Greer; Seth D Crockett; Andrew Baer; Robert E Schoen
Journal:  Gastrointest Endosc       Date:  2017-09-01       Impact factor: 9.427

Review 6.  High-resolution microendoscopy in differentiating neoplastic from non-neoplastic colorectal polyps.

Authors:  Justin S Louie; Richa Shukla; Rebecca Richards-Kortum; Sharmila Anandasabapathy
Journal:  Best Pract Res Clin Gastroenterol       Date:  2015-06-04       Impact factor: 3.043

7.  Public reporting of colonoscopy quality is associated with an increase in endoscopist adenoma detection rate.

Authors:  Heitham Abdul-Baki; Robert E Schoen; Katie Dean; Sherri Rose; Daniel A Leffler; Eliathamby Kuganeswaran; Michele Morris; David Carrell; Ateev Mehrotra
Journal:  Gastrointest Endosc       Date:  2015-10       Impact factor: 9.427

8.  The impact of exclusion criteria on a physician's adenoma detection rate.

Authors:  Felippe O Marcondes; Katie M Dean; Robert E Schoen; Daniel A Leffler; Sherri Rose; Michele Morris; Ateev Mehrotra
Journal:  Gastrointest Endosc       Date:  2015-10       Impact factor: 9.427

9.  Prolonged Cecal Insertion Time Is Not Associated with Decreased Adenoma Detection When a Longer Withdrawal Time Is Achieved.

Authors:  Cassandra D L Fritz; Zachary L Smith; Jeffrey Elsner; Thomas Hollander; Dayna Early; Vladimir Kushnir
Journal:  Dig Dis Sci       Date:  2018-05-03       Impact factor: 3.199

10.  Colorectal neoplasia detection among black and Latino individuals undergoing screening colonoscopy: a prospective cohort study.

Authors:  Kristen K Lee; Lina Jandorf; Linda Thélèmaque; Steven H Itzkowitz
Journal:  Gastrointest Endosc       Date:  2014-03       Impact factor: 9.427

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.