Literature DB >> 17145377

Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers.

Murray Blythe1, Karl Stoffel, Paul Jarrett, Markus Kuster.   

Abstract

PURPOSE: To compare the stability and stiffness of dorsal and volar fixed-angle distal radius constructs in a cadaveric model.
METHODS: A locking distal radius system was used in a combination of a dorsal and styloid plate (group 1), a single volar plate (group 2), and a combination of a volar and styloid plate (group 3) configuration. In addition a single volar 3.5-mm steel locking plate was used in group 4. Each construct was tested on 6 fresh-frozen radii with simulated unstable dorsally comminuted extra-articular distal radius fractures. Specimens were tested on a material testing machine with an extensometer and subjected to axial compression fatigue and load-to-failure testing.
RESULTS: No construct failed in fatigue testing of 250 N for 5,000 cycles. Two specimens in each group were tested for 20,000 cycles without failure. The plastic deformation in the double-plate groups was lower compared with the single-plate groups, although the difference was not statistically significant. Group 1 had the highest and group 4 the lowest failure load and stiffness, respectively. The differences between group 1 and the other groups, except failure load compared with group 3, were statistically significant. Groups 2 and 3 had a significantly higher load to failure and group 3 had a significantly higher stiffness compared with group 4.
CONCLUSIONS: All constructs offer adequate stability with minimal deformation on fatigue testing under physiologic conditions. Dorsal fixed-angle constructs are stiffer and stronger than volar constructs. The addition of a styloid plate to a volar plate did not significantly improve stability in this model of simulated extra-articular dorsal comminution loaded in axial compression.

Entities:  

Mesh:

Year:  2006        PMID: 17145377     DOI: 10.1016/j.jhsa.2006.09.011

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  13 in total

1.  Appropriately Matched Fixed-Angle Locking Plates Improve Stability in Volar Distal Radius Fixation.

Authors:  Natalia D McIver; Christina Salas; Nathan Menon; John Heifner; Deana Mercer
Journal:  J Hand Surg Glob Online       Date:  2022-04-04

2.  Biomechanical comparison of different volar fracture fixation plates for distal radius fractures.

Authors:  Kareem Sobky; Todd Baldini; Kenneth Thomas; Joel Bach; Allison Williams; Jennifer Moriatis Wolf
Journal:  Hand (N Y)       Date:  2007-09-07

3.  Complications of Radial Column Plating of the Distal Radius.

Authors:  Samuel E Galle; Neil G Harness; Jacques H Hacquebord; Raoul J Burchette; Brett Peterson
Journal:  Hand (N Y)       Date:  2018-02-27

4.  Biomechanical stability of four fixation constructs for distal radius fractures.

Authors:  John T Capo; Tosca Kinchelow; Kenneth Brooks; Virak Tan; Michaele Manigrasso; Kristin Francisco
Journal:  Hand (N Y)       Date:  2009-02-05

5.  The influence of distal screw length on the primary stability of volar plate osteosynthesis--a biomechanical study.

Authors:  Sebastian F Baumbach; Alexander Synek; Hannes Traxler; Wolf Mutschler; Dieter Pahr; Yan Chevalier
Journal:  J Orthop Surg Res       Date:  2015-09-08       Impact factor: 2.359

6.  Comparison of Risk of Carpal Tunnel Syndrome in Patients with Distal Radius Fractures After 7 Treatments.

Authors:  Huan-Li Zhao; Gui-Bin Wang; Yue-Qing Jia; Shi-Cai Zhu; Feng-Fang Zhang; Hong-Mei Liu
Journal:  Med Sci Monit       Date:  2015-09-22

7.  Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures.

Authors:  F Wichlas; N P Haas; A Disch; D Machó; S Tsitsilonis
Journal:  J Orthop Traumatol       Date:  2014-07-16

8.  Different osteosyntheses for Colles' fracture: a mechanical study in 42 cadaver bones.

Authors:  Yngvar Krukhaug; Nils R Gjerdet; Odd J Lundberg; Peer K Lilleng; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

9.  Assessment of a novel biomechanical fracture model for distal radius fractures.

Authors:  Sebastian Felix Baumbach; Enrico Dall'Ara; Patrick Weninger; Anna Antoni; Hannes Traxler; Martin Dörr; Philippe K Zysset
Journal:  BMC Musculoskelet Disord       Date:  2012-12-18       Impact factor: 2.362

10.  Biomechanical comparison of osteoporotic distal radius fractures fixed by distal locking screws with different length.

Authors:  Xiong Liu; Wei-dong Wu; Ya-feng Fang; Mei-chao Zhang; Wen-hua Huang
Journal:  PLoS One       Date:  2014-07-31       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.