Literature DB >> 17141349

Non-invasive glucose monitoring: assessment of technologies and devices according to quantitative criteria.

Andrea Tura1, Alberto Maran, Giovanni Pacini.   

Abstract

Aim of this review was to describe the main technologies for non-invasive glucose monitoring and the corresponding most relevant devices. The review tries to overcome the limitations of previous reviews on this topic, such as the lack of objective criteria for inclusion or exclusion of technologies or devices, and the poor organization of the information, which often does not allow easy comparison between technologies and devices. In this review, the information is concise and organized into specific categories, and hence it becomes easy to compare advantages and disadvantages of the different technologies and devices. For technologies, the categories of information considered are the technology name, the underlying physical principle, the technology limitations and the measurement sites on the human body. For devices, the categories of information are the device name, its approval condition (FDA Approval and/or CE Mark), the technology on which it is based, a device general description, the tests performed on the device, the corresponding results, safety information, aspects affecting usability, current status of the device and the manufacturer, an Internet reference for the device. A total of 14 technologies and 16 devices are included. Conclusions of the review were that, despite some interesting and promising technologies and devices, a satisfactory solution to the non-invasive glucose monitoring problem still requires further efforts.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17141349     DOI: 10.1016/j.diabres.2006.10.027

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  27 in total

1.  In vivo glucose monitoring using dual-wavelength polarimetry to overcome corneal birefringence in the presence of motion.

Authors:  Casey W Pirnstill; Bilal H Malik; Vincent C Gresham; Gerard L Coté
Journal:  Diabetes Technol Ther       Date:  2012-06-12       Impact factor: 6.118

Review 2.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system.

Authors:  Mattia Zanon; Giovanni Sparacino; Andrea Facchinetti; Michela Riz; Mark S Talary; Roland E Suri; Andreas Caduff; Claudio Cobelli
Journal:  Med Biol Eng Comput       Date:  2012-06-22       Impact factor: 2.602

Review 4.  Hypo- and Hyperglycemic Alarms: Devices and Algorithms.

Authors:  Daniel Howsmon; B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2015-04-30

Review 5.  Single-walled carbon nanotube-based near-infrared optical glucose sensors toward in vivo continuous glucose monitoring.

Authors:  Kyungsuk Yum; Thomas P McNicholas; Bin Mu; Michael S Strano
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

6.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; Mark Arnold; George L Bakris; David E Bruns; Andrea Rita Horvath; M Sue Kirkman; Ake Lernmark; Boyd E Metzger; David M Nathan
Journal:  Diabetes Care       Date:  2011-06       Impact factor: 19.112

7.  Comparison of salivary and serum glucose levels in diabetic patients.

Authors:  Shruti Gupta; Simarpreet Virk Sandhu; Himanta Bansal; Deepti Sharma
Journal:  J Diabetes Sci Technol       Date:  2014-10-07

Review 8.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

9.  Raman spectroscopy as a promising tool for noninvasive point-of-care glucose monitoring.

Authors:  Maarten J Scholtes-Timmerman; Sabina Bijlsma; Marion J Fokkert; Robbert Slingerland; Sjaak J F van Veen
Journal:  J Diabetes Sci Technol       Date:  2014-07-18

10.  Detection and Monitoring of Microparticles Under Skin by Optical Coherence Tomography as an Approach to Continuous Glucose Sensing Using Implanted Retroreflectors.

Authors:  Shang Wang; Tim Sherlock; Betsy Salazar; Narendran Sudheendran; Ravi Kiran Manapuram; Katerina Kourentzi; Paul Ruchhoeft; Richard C Willson; Kirill V Larin
Journal:  IEEE Sens J       Date:  2013-11-01       Impact factor: 3.301

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.