Literature DB >> 17137990

Scheimpflug measurement of intraocular lens position after piggyback implantation of foldable intraocular lenses in eyes with high hyperopia.

Martin Baumeister1, Thomas Kohnen.   

Abstract

PURPOSE: To investigate the position of 3-piece foldable intraocular lenses (IOLs) after piggyback implantation for high hyperopia.
SETTING: University Eye Hospital, Johann Wolfgang Goethe University, Frankfurt am Main, Germany.
METHODS: Eight eyes of 5 highly hyperopic patients had phacoemulsification and implantation of 2 foldable IOLs. In 3 eyes, both IOLs were implanted in the capsular bag. In 5 eyes, 1 IOL was placed in the capsular bag and the second IOL in the ciliary sulcus. Intraocular lens optic tilt and decentration, combined thickness of both IOLs, and anterior chamber depth (ACD) were measured postoperatively over a period of 18 months using Scheimpflug photography.
RESULTS: All eyes with both IOLs in the capsular bag showed interpseudophakic opacification, with a mean increase in combined IOL thickness of 0.4 mm, a decrease in ACD of 0.3 mm, and a corresponding hyperopic shift of 4.00 diopters. Eyes in which the anterior IOL was placed in the ciliary sulcus showed no changes in refraction or combined IOL thickness. In these eyes, the anterior IOL had a higher mean decentration (0.49 mm +/- 0.20 [SD] after 12 months) than the posterior IOL (0.21 +/- 0.13 mm after 12 months).
CONCLUSIONS: Piggyback IOL implantation with placement of 2 foldable IOLs in the capsular bag can be followed by a hyperopic shift that may be caused in part by displacement of the IOLs. Placement of the anterior IOL in the ciliary sulcus can lead to higher decentration of this IOL.

Entities:  

Mesh:

Year:  2006        PMID: 17137990     DOI: 10.1016/j.jcrs.2006.08.033

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  [Pseudophakic supplementary intraocular lenses].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2010-08       Impact factor: 1.059

Review 2.  [Scheimpflug photography for the examination of phakic intraocular lenses].

Authors:  M Baumeister
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

3.  Pathologic assessment of complications with asymmetric or sulcus fixation of square-edged hydrophobic acrylic intraocular lenses.

Authors:  Kevin R Kirk; Liliana Werner; Ryan Jaber; Susan Strenk; Lawrence Strenk; Nick Mamalis
Journal:  Ophthalmology       Date:  2012-03-15       Impact factor: 12.079

4.  Influence of lens position as detected by an anterior segment analysis system on postoperative refraction in cataract surgery.

Authors:  Jia-Ju Zhang; Jian-Qing Li; Chen Li; Yi-Hong Cao; Pei-Rong Lu
Journal:  Int J Ophthalmol       Date:  2021-07-18       Impact factor: 1.779

5.  Long-term results of clear lens extraction combined with piggyback intraocular lens implantation to correct high hyperopia.

Authors:  Xia Hua; Xiao-Yong Yuan; Hui Song; Xin Tang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

6.  [Refractive long-term results after piggyback intraocular lens implantation].

Authors:  B Moustafa; H Häberle; C Wirbelauer; D T Pham
Journal:  Ophthalmologe       Date:  2007-09       Impact factor: 1.059

7.  Cataract Surgery with a New Fluidics Control Phacoemulsification System in Nanophthalmic Eyes.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  Case Rep Ophthalmol       Date:  2016-10-21

8.  Research on calculation of the IOL tilt and decentration based on surface fitting.

Authors:  Lin Li; Ke Wang; Yan Yan; Xudong Song; Zhicheng Liu
Journal:  Comput Math Methods Med       Date:  2013-07-14       Impact factor: 2.238

Review 9.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.