Literature DB >> 17130797

Silicone allergy: A new cause for cochlear implant extrusion and its management.

Larisa D Kunda1, Katrina R Stidham, Michelle M Inserra, Peter S Roland, Daniel Franklin, Joseph B Roberson.   

Abstract

OBJECTIVE: We introduce silicone allergy as a rare cause for cochlear implant extrusion and discuss its management. STUDY
DESIGN: Retrospective case series and literature review.
SETTING: Tertiary referral centers. PATIENTS: Primary eligibility criteria included patients who experienced a delayed extrusion of their cochlear implants with negative wound cultures and had a suspected or a test-proven allergy to silicone components of an implant.
INTERVENTIONS: Silicone allergy testing, explantation of a cochlear implant containing allergenic silicone materials, reimplantation with a custom-made cochlear implant excluding an allergenic silicone component. OUTCOME MEASURES: Uneventful wound healing and extrusion-free long-term follow-up after the reimplantation with a custom-made cochlear implant excluding an allergenic silicone component.
RESULTS: Three known cases of cochlear implant extrusion as a result of silicone allergy have been noted from 1991 through 2004 in three cochlear implant programs in the United States. All three devices extruded, resulting in explantation of the old device and reimplantation with a new custom-made device eliminating the allergenic silicone component. Wound cultures were negative in all cases. All three patients experienced a delayed extrusion of their devices. Two of these patients had a test-proven allergy to the implant's silicone components, whereas the third patient was presumed to have a hypersensitivity solely on the basis of a clinical presentation.
CONCLUSION: We propose that silicone allergy is a rare cause of cochlear implant extrusion. Patients experiencing cochlear implant extrusion, particularly with a delayed onset and negative wound culture results, should be tested for silicone allergy.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17130797     DOI: 10.1097/01.mao.0000235378.64654.4d

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  14 in total

1.  Foreign body or hypersensitivity granuloma of the inner ear after cochlear implantation: one possible cause of a soft failure?

Authors:  Joseph B Nadol; Donald K Eddington; Barbara J Burgess
Journal:  Otol Neurotol       Date:  2008-12       Impact factor: 2.311

2.  The pattern and degree of capsular fibrous sheaths surrounding cochlear electrode arrays.

Authors:  Reuven Ishai; Barbara S Herrmann; Joseph B Nadol; Alicia M Quesnel
Journal:  Hear Res       Date:  2017-02-17       Impact factor: 3.208

3.  Intracochlear inflammatory response to cochlear implant electrodes in humans.

Authors:  Mohammad Seyyedi; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2014-10       Impact factor: 2.311

Review 4.  Surgery of the ear and the lateral skull base: pitfalls and complications.

Authors:  Bernhard Schick; Julia Dlugaiczyk
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2013-12-13

5.  Foreign Body Response to Silicone in Cochlear Implant Electrodes in the Human.

Authors:  Jennifer T O'Malley; Barbara J Burgess; Donald Galler; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2017-08       Impact factor: 2.311

6.  Delayed type IV hypersensitivity reaction to porcine acellular dermal matrix masquerading as infection resulting in multiple debridements.

Authors:  P Vedak; J St John; A Watson; L Garibyan; M C Mihm; R M Nazarian; P C Levins; C L Cetrulo; P Schalock; D Kroshinsky
Journal:  Hernia       Date:  2015-12-22       Impact factor: 4.739

Review 7.  [Allergic reactions to bioimplants].

Authors:  L Klimek
Journal:  HNO       Date:  2022-03-28       Impact factor: 1.284

8.  Immuno-detection of Staphylococcus aureus biofilm on a cochlear implant.

Authors:  M I Kos; L Stenz; P François; J-P Guyot; J Schrenzel
Journal:  Infection       Date:  2009-03-10       Impact factor: 3.553

9.  Cellular immunologic responses to cochlear implantation in the human.

Authors:  Joseph B Nadol; Jennifer T O'Malley; Barbara J Burgess; Donald Galler
Journal:  Hear Res       Date:  2014-10-05       Impact factor: 3.208

10.  Histopathological Effects of Parylene C (poly-chloro-p-xylylene) in the Inner Ear.

Authors:  Raşit Cevizci; Mehmet Düzlü; Pınar Göçün Uyar; Recep Karamert; Selin Üstün Bezgin; Hakan Tutar; Nebil Göksu; Yıldırım Ahmet Bayazıt
Journal:  Turk Arch Otorhinolaryngol       Date:  2016-06-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.