Assessment of effects of a radiofrequency energy field and thermistor location in an electrode catheter on the accuracy of temperature measurement.

L T Blouin1, F I Marcus, L Lampe.   

Abstract

Accurate measurement of temperature at the interface of the delivery electrode and the tissue during transcatheter delivery of radiofrequency energy (RFE) for ablation would provide better control of lesion production. Electromagnetic energy fields can affect the accuracy of temperature measurement with thermistors. An electrode probe was fabricated with a thermistor and an optical sensor in the center of the delivery electrode. Simultaneous temperature measurements during RFE delivery to cardiac tissue in the 37 degrees C bath showed good agreement between the sensors, indicating that the RFE field did not cause errors in thermistor temperature measurements with the electrode probe used. A second electrode probe was designed to determine optimal thermistor location. It was constructed using two thermistors with identical temperature-resistance curves. One thermistor protruded through a hole in the side of the delivery electrode and was thermally isolated from it. The other thermistor was bonded to the inner surface of the electrode with heat conductive epoxy. The electrode was placed in contact with cardiac tissue in a 37 degrees C bath of flowing saline with the protruding thermistor centered in the area to be heated. Temperatures measured at steady state during RFE delivery with the protruding thermistor were consistently higher than those of the inner wall thermistor, ranging from 1.8 degrees C difference at 46 degrees C to 8.3 degrees C difference at 75 degrees C interface temperature. The thermistor must be in contact with the tissue and thermally isolated from the delivery electrode for accurate determination of electrode/tissue interface temperature.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1712958     DOI: 10.1111/j.1540-8159.1991.tb04111.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  Bio-battery signal predicts myocardial lesion formation and depth in vitro.

Authors:  D S He; P Sharma; X Wang; M Bosnos; F I Marcus
Journal:  J Interv Card Electrophysiol       Date:  1999-03       Impact factor: 1.900

Review 2.  Deciphering cryptic proteases.

Authors:  M A Liz; M M Sousa
Journal:  Cell Mol Life Sci       Date:  2005-05       Impact factor: 9.261

3.  Interrelation of tissue temperature versus flow velocity in two different kinds of temperature controlled catheter radiofrequency energy applications.

Authors:  S Grumbrecht; J Neuzner; H F Pitschner
Journal:  J Interv Card Electrophysiol       Date:  1998-06       Impact factor: 1.900

4.  Thermal expansion imaging for monitoring lesion depth using M-mode ultrasound during cardiac RF ablation: in vitro study.

Authors:  Peter Baki; Sergio J Sanabria; Gabor Kosa; Gabor Szekely; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

5.  Thermal strain imaging: a review.

Authors:  Chi Hyung Seo; Yan Shi; Sheng-Wen Huang; Kang Kim; Matthew O'Donnell
Journal:  Interface Focus       Date:  2011-05-23       Impact factor: 3.906

6.  The feasibility of using thermal strain imaging to regulate energy delivery during intracardiac radio-frequency ablation.

Authors:  Chi Hyung Seo; Douglas N Stephens; Jonathan Cannata; Aaron Dentinger; Feng Lin; Suhyun Park; Douglas Wildes; Kai E Thomenius; Peter Chen; Tho Nguyen; Alan de La Rama; Jong Seob Jeong; Aman Mahajan; Kalyanam Shivkumar; Amin Nikoozadeh; Omer Oralkan; Uyen Truong; David J Sahn; Pierre T Khuri-Yakub; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-07       Impact factor: 2.725

Review 7.  [Catheter ablation of ventricular tachycardia : What have we achieved?]

Authors:  T Konrad; B A Hoffmann; T Rostock
Journal:  Herz       Date:  2017-04       Impact factor: 1.443

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.