Literature DB >> 1712421

The use of gradient flow compensation to separate diffusion and microcirculatory flow in MRI.

J H Maki1, J R MacFall, G A Johnson.   

Abstract

This paper describes a new MR imaging technique termed Modified Stejskal Tanner versus Flow Compensation (MST/FC) for the separation of diffusion and microcirculatory flow. The theory behind the sequence is explained, along with a five-component model of microcirculation applicable to any "perfusion" imaging technique. Phantom data is presented showing that (1) diffusion effects can be matched between MST and FC (suggesting the possibility of flow-compensated diffusion imaging), and (2) the technique is a quantitative method of separating diffusion and slow (less than 0.25 mm/s) tortuous flow through a Sephadex column. Furthermore, animal images show the technique to be feasible and quantitative in measuring rat brain microcirculation under normal, vasodilated (hypercarbia), and no-flow (post mortem) conditions.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1712421     DOI: 10.1002/mrm.1910170114

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Interstitial fluid pressure correlates with intravoxel incoherent motion imaging metrics in a mouse mammary carcinoma model.

Authors:  Sungheon Kim; Lindsey Decarlo; Gene Y Cho; Jens H Jensen; Daniel K Sodickson; Linda Moy; Silvia Formenti; Robert J Schneider; Judith D Goldberg; Eric E Sigmund
Journal:  NMR Biomed       Date:  2011-11-09       Impact factor: 4.044

2.  Quantifying venous flow dynamics by flow-dephased and flow-rephased functional magnetic resonance imaging.

Authors:  Thies H Jochimsen; Harald E Möller
Journal:  MAGMA       Date:  2005-11-23       Impact factor: 2.310

Review 3.  On high b diffusion imaging in the human brain: ruminations and experimental insights.

Authors:  Robert V Mulkern; Steven J Haker; Stephan E Maier
Journal:  Magn Reson Imaging       Date:  2009-06-10       Impact factor: 2.546

4.  The Effect of Microcirculatory Flow on Oscillating Gradient Diffusion MRI and Diffusion Encoding with Dual-Frequency Orthogonal Gradients (DEFOG).

Authors:  Dan Wu; Jiangyang Zhang
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

5.  Quantitative measurement of cerebral blood volume using velocity-selective pulse trains.

Authors:  Dexiang Liu; Feng Xu; Doris D Lin; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-10-31       Impact factor: 4.668

Review 6.  Physical and numerical phantoms for the validation of brain microstructural MRI: A cookbook.

Authors:  Els Fieremans; Hong-Hsi Lee
Journal:  Neuroimage       Date:  2018-06-18       Impact factor: 6.556

7.  Precision of region of interest-based tri-exponential intravoxel incoherent motion quantification and the role of the Intervoxel spatial distribution of flow velocities.

Authors:  Gregory Simchick; Diego Hernando
Journal:  Magn Reson Med       Date:  2022-08-15       Impact factor: 3.737

8.  Spatial Mapping of Translational Diffusion Coefficients Using Diffusion Tensor Imaging: A Mathematical Description.

Authors:  Anil N Shetty; Sharon Chiang; Mirjana Maletic-Savatic; Gregor Kasprian; Marina Vannucci; Wesley Lee
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2014-04-15       Impact factor: 0.481

9.  Accelerated spin-echo functional MRI using multisection excitation by simultaneous spin-echo interleaving (MESSI) with complex-encoded generalized slice dithered enhanced resolution (cgSlider) simultaneous multislice echo-planar imaging.

Authors:  SoHyun Han; Congyu Liao; Mary Kate Manhard; Daniel Joseph Park; Berkin Bilgic; Merlin J Fair; Fuyixue Wang; Anna I Blazejewska; William A Grissom; Jonathan R Polimeni; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-12-16       Impact factor: 4.668

10.  Characterizing tumor response to chemotherapy at various length scales using temporal diffusion spectroscopy.

Authors:  Junzhong Xu; Ke Li; R Adam Smith; John C Waterton; Ping Zhao; Heidi Chen; Mark D Does; H Charles Manning; John C Gore
Journal:  PLoS One       Date:  2012-07-24       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.