Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.

S Portnoy1, G Yarnitzky, Z Yizhar, A Kristal, U Oppenheim, I Siev-Ner, A Gefen.   

Abstract

Fitting of a prosthetic socket is a critical stage in the process of rehabilitation of a trans-tibial amputation (TTA) patient, since a misfit may cause pressure ulcers or a deep tissue injury (DTI: necrosis of the muscle flap under intact skin) in the residual limb. To date, prosthetic fitting typically depends on the subjective skills of the prosthetist, and is not supported by biomedical instrumentation that allows evaluation of the quality of fitting. Specifically, no technology is presently available to provide real-time continuous information on the internal distribution of mechanical stresses in the residual limb during fitting of the prosthesis, or while using it and this severely limits patient evaluations. In this study, a simplified yet clinically oriented patient-specific finite element (FE) model of the residual limb was developed for real-time stress analysis. For this purpose we employed a custom-made FE code that continuously calculates internal stresses in the residual limb, based on boundary conditions acquired in real-time from force sensors, located at the limb-prosthesis interface. Validation of the modeling system was accomplished by means of a synthetic phantom of the residual limb, which allowed simultaneous measurements of interface pressures and internal stresses. Human studies were conducted subsequently in five TTA patients. The dimensions of bones and soft tissues were obtained from X-rays of the residual limb of each patient. An indentation test was performed in order to obtain the effective elastic modulus of the soft tissues of the residual limb. Seven force sensors were placed between the residual limb and the prosthetic liner, and subjects walked on a treadmill during analysis. Generally, stresses under the shinbones were approximately threefold higher than stresses at the soft tissues behind the bones. Usage of a thigh corset decreased the stresses in the residual limb during gait by approximately 80%. Also, the stresses calculated during the trial of a subject who complained about pain and discomfort were the highest, confirming that his socket was not adequately fitted. We conclude that real-time patient-specific FE analysis of internal stresses in deep soft tissues of the residual limb in TTA patients is feasible. This method is promising for improving the fitting of prostheses in the clinical setting and for protecting the residual limb from pressure ulcers and DTI.

Entities:  

Mesh:

Year:  2006        PMID: 17120139     DOI: 10.1007/s10439-006-9208-3

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  8 in total

1.  FEBio: finite elements for biomechanics.

Authors:  Steve A Maas; Benjamin J Ellis; Gerard A Ateshian; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2012-01       Impact factor: 2.097

2.  Computer-socket manufacturing error: how much before it is clinically apparent?

Authors:  Joan E Sanders; Michael R Severance; Kathryn J Allyn
Journal:  J Rehabil Res Dev       Date:  2012

3.  Experimental and computational analysis of composite ankle-foot orthosis.

Authors:  Dequan Zou; Tao He; Michael Dailey; Kirk E Smith; Matthew J Silva; David R Sinacore; Michael J Mueller; Mary K Hastings
Journal:  J Rehabil Res Dev       Date:  2014

4.  Developing a control framework for self-adjusting prosthetic sockets incorporating tissue injury risk estimation and generalized predictive control.

Authors:  F M Mbithi; A J Chipperfield; J W Steer; A S Dickinson
Journal:  Biomed Eng Lett       Date:  2021-12-02

5.  Exploring the role of transtibial prosthetic use in deep tissue injury development: a scoping review.

Authors:  Marisa Graser; Sarah Day; Arjan Buis
Journal:  BMC Biomed Eng       Date:  2020-01-29

6.  Computational modeling for bedside application.

Authors:  Roy C P Kerckhoffs; Sanjiv M Narayan; Jeffrey H Omens; Lawrence J Mulligan; Andrew D McCulloch
Journal:  Heart Fail Clin       Date:  2008-07       Impact factor: 3.179

Review 7.  The use of fiber Bragg grating sensors in biomechanics and rehabilitation applications: the state-of-the-art and ongoing research topics.

Authors:  Ebrahim Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2012-09-25       Impact factor: 3.576

8.  Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method.

Authors:  Mohd Syahmi Jamaludin; Akihiko Hanafusa; Yamamoto Shinichirou; Yukio Agarie; Hiroshi Otsuka; Kengo Ohnishi
Journal:  Bioengineering (Basel)       Date:  2019-10-24
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.