Literature DB >> 17112902

Novel magnetic rings for rapid vascular reconstruction in canine liver transplantation model.

Y Shi1, Y Lv, B Wang, Y Zhang, A Jiang, J H Li, X F Zhang, Q Y Li, K W Meng, C Liu, L Yu, C E Pan.   

Abstract

OBJECTIVE: Magnetic rings were used for rapid vascular reconstruction in a canine liver transplantation model.
MATERIALS AND METHODS: Thirty-two adult mongrel dogs weighing 13 to 16 kg were randomly selected as donors or recipients of transplantations. The recipients were randomly divided into two groups: group A (n = 10) had magnetic rings used for vascular reconstruction without venovenous bypass; group B (n = 6) had vascular reconstruction performed by continuous suturing with splenojugular venovenous bypass.
RESULTS: In group A, the entire operative period was 3.24 +/- 0.49 hours, the durations of clamping the portal vein and the infrahepatic vena cava of the recipient were 5.89 +/- 2.27 minutes and 3.89 +/- 0.73 minutes, respectively. In group B, the entire operative period was 4.12 +/- 0.51 hours with the duration of clamping portal vein and infrahepatic vena cava, 28.33 +/- 6.04 minutes and 12.16 +/- 3.72 minutes (P < .01 vs group A). In group A, mean arterial pressure dropped during the anhepatic phase but recovered quickly after reperfusion. The fluid infusion was about 730.56 +/- 50.56 mL in the group A and a pressor agent was unnecessary. In group B, blood pressure dropped during the anhepatic phase and slowly recovered. The fluid infusion was about 2241.67 +/- 390.78 mL and a pressor agent was used to maintain the blood pressure of the recipient. No twist or thrombus was discovered in the anastomoses group A and the endothelium at the site of anastomosis was entire. In group B, errhysis was common in the anastomotic stomas. Nine of 10 dogs in group A survived more than 3 days, the longest being 8 days, whereas four of the six dogs in group B survived less than 3 days.
CONCLUSION: The results showed that the anhepatic time was significantly shortened (about 5.89 +/- 2.27 minutes) in group A compared with group B and venovenous bypass was unnecessary. Magnetic rings could be used for rapid vascular reconstruction in canine liver transplantation model. The long-term results of this procedure should be clarified before it is applied in clinical practice in the future.

Entities:  

Mesh:

Year:  2006        PMID: 17112902     DOI: 10.1016/j.transproceed.2006.08.174

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  5 in total

1.  Magnetic Anastomosis Rings to Create Portacaval Shunt in a Canine Model of Portal Hypertension.

Authors:  Hao-Hua Wang; Jia Ma; Shan-Pei Wang; Feng Ma; Jian-Wen Lu; Xiang-Hua Xu; Yi Lv; Xiao-Peng Yan
Journal:  J Gastrointest Surg       Date:  2018-08-21       Impact factor: 3.452

2.  Extrahepatic portacaval shunt via a magnetic compression technique: A cadaveric feasibility study.

Authors:  Xiao-Peng Yan; Wen-Yan Liu; Jia Ma; Jian-Peng Li; Yi Lv
Journal:  World J Gastroenterol       Date:  2015-07-14       Impact factor: 5.742

3.  A novel magnetic compression technique for cystostomy in rabbits.

Authors:  Miaomiao Zhang; Jianqi Mao; Yixing Li; Shuqin Xu; Jingci Gai; Ting Lan; Yirui Wang; Yuxiang Ren; Aihua Shi; Yi Lyu; Xiaopeng Yan
Journal:  Sci Rep       Date:  2022-07-16       Impact factor: 4.996

4.  Novel magnetic compression technique for establishment of a canine model of tracheoesophageal fistula.

Authors:  Yi Gao; Rong-Qian Wu; Yi Lv; Xiao-Peng Yan
Journal:  World J Gastroenterol       Date:  2019-08-14       Impact factor: 5.742

5.  Portacaval shunt established in six dogs using magnetic compression technique.

Authors:  Xiaopeng Yan; Chao Fan; Jia Ma; Jianhui Li; Dinghui Dong; Haohua Wang; Feng Ma; Xinglong Zheng; Yi Lv
Journal:  PLoS One       Date:  2013-09-30       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.