Literature DB >> 17102662

Dynamic contour tonometry: a new way to assess intraocular pressure in ectatic corneas.

Zeynep Ozbek1, Elisabeth J Cohen, Kristin M Hammersmith, Christopher J Rapuano.   

Abstract

PURPOSE: To compare intraocular pressure (IOP) measurements in patients with keratoconus (KC), pellucid marginal degeneration (PMD), and unilateral penetrating keratoplasty (PK) for KC by Goldmann applanation tonometry (GAT), Tono-Pen tonometry (TP), and Pascal dynamic contour tonometry (DCT).
METHODS: Patients with KC, PMD, or PK were included in a prospective study. IOPs were measured by GAT, TP, and DCT. Severity of ectasia was determined by the steep curvature by corneal topography and central thinning by contact ultrasound pachymetry. IOP measurements were compared and correlated with disease severity.
RESULTS: Fifty-three eyes of 36 patients were enrolled. Mean age was 45.3 +/- 12.5 years (range: 28-72 years). Twenty-nine eyes had KC, 21 eyes had a PK for KC, and 3 eyes had PMD. Mean DCT, GAT, and TP readings were 16.1 +/- 2.9, 14.3 +/- 4.1, and 13.8 +/- 4.1 mm Hg, respectively. The differences of mean IOP between GAT and DCT and TP and DCT were statistically significant, whereas the difference between GAT and TP was not. Both GAT and TP readings were significantly higher in the PK eyes than the KC and PMD eyes, whereas DCT readings were not. DCT measurements were not significantly different in PK versus non-PK eyes.
CONCLUSION: DCT is a newly Food and Drug Administration (FDA)-approved device that is designed to measure IOP, independent of corneal thickness, corneal curvature, and ocular rigidity. DCT gave significantly higher IOP readings than GAT and TP in this study. DCT readings were not affected by corneal thickness. DCT may be more accurate in IOP measurement in eyes with KC and PMD.

Entities:  

Mesh:

Year:  2006        PMID: 17102662     DOI: 10.1097/01.ico.0000224649.12214.33

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  9 in total

1.  The influence of corneal geometrical and biomechanical properties on tonometry readings in keratoconic eyes.

Authors:  Mustafa Değer Bilgeç; Eray Atalay; Ömer Sözer; Hüseyin Gürsoy; Muzaffer Bilgin; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2019-12-02       Impact factor: 2.031

2.  Keratoconus and normal-tension glaucoma: a study of the possible association with abnormal biomechanical properties as measured by corneal hysteresis (An AOS Thesis).

Authors:  Elisabeth J Cohen
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

3.  [Evaluation of dynamic contour tonometry in keratoconus].

Authors:  N Schädle; J D Unterlauft; T Klink; G Geerling
Journal:  Ophthalmologe       Date:  2009-06       Impact factor: 1.059

4.  Which tonometry in eyes with keratoconus?

Authors:  H Altinkaynak; C Kocasarac; H Dundar; N Sayin; N Kara; E Bozkurt; N Duru
Journal:  Eye (Lond)       Date:  2015-12-04       Impact factor: 3.775

5.  Twenty-four hours intraocular pressure in keratoconic eyes assessed by applanation tonometry and Tono-Pen AVIA.

Authors:  Rafael Vidal Merola; Sebastião Cronemberger; Artur William Veloso; Alberto Diniz-Filho
Journal:  Int J Ophthalmol       Date:  2022-01-18       Impact factor: 1.779

6.  Intraocular Pressure Measurements Referring to the Corneal Thickness in Keratoconic Eyes After Corneal Crosslinking with Riboflavin and Ultraviolet A.

Authors:  Sanja Sefic Kasumovic; Milka Mavija; Aida Kasumovic; Orhan Lepara; Belkisa Duric-Colic; Emir Cabric; Lejla Muhamedagic; Adisa Sakovic-Racic; Mirko Jankov
Journal:  Med Arch       Date:  2015-10-04

7.  Utility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractive surgery.

Authors:  Sang Yeop Lee; Hyoung Won Bae; Hee Jung Kwon; Gong Je Seong; Chan Yun Kim
Journal:  PLoS One       Date:  2018-02-05       Impact factor: 3.240

Review 8.  Intraocular Pressure Measurement after Penetrating Keratoplasty.

Authors:  Otilia-Maria Dumitrescu; Sinziana Istrate; Mioara-Laura Macovei; Alina Gabriela Gheorghe
Journal:  Diagnostics (Basel)       Date:  2022-01-19

9.  Steroid induced ocular hypertension following myopic photorefractive keratectomy.

Authors:  Mohammad-Ali Javadi; Firooz Mirbabaei-Ghafghazi; Monirsadat Mirzade; Shahin Yazdani; Mehdi Yaseri
Journal:  J Ophthalmic Vis Res       Date:  2008-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.