Literature DB >> 17100667

A preliminary study on the association between ventilation rates in classrooms and student performance.

R J Shaughnessy1, U Haverinen-Shaughnessy, A Nevalainen, D Moschandreas.   

Abstract

Poor conditions leading to substandard indoor air quality (IAQ) in classrooms have been frequently cited in the literature over the past two decades. However, there is limited data linking poor IAQ in the classrooms to student performance. Whereas, it is assumed that poor IAQ results in reduced attendance and learning potential, and subsequent poor student performance, validating this hypothesis presents a challenge in today's school environment. This study explores the association between student performance on standardized aptitude tests that are administered to students on a yearly basis, to classroom carbon dioxide (CO2) concentrations, which provide a surrogate of ventilation being provided to each room. Data on classroom CO2 concentrations (over a 4-5 h time span within a typical school day) were recorded in fifth grade classrooms in 54 elementary schools within a school district in the USA. Results from this preliminary study yield a significant (P < 0.10) association between classroom-level ventilation rate and test results in math. They also indicate that non-linear effects may need to be considered for better representation of the association. A larger sample size is required in order to draw more definitive conclusions. Practical Implications Future studies could focus on (1) gathering more evidence on the possible association between classroom ventilation rates and students' academic performance; (2) the linear/non-linear nature of the association; and (3) whether it is possible to detect 'no observed adverse effect level' for adequate ventilation with respect to academic performance in schools. All of this information could be used to improve guidance and take regulatory actions to ensure adequate ventilation in schools. The high prevalence of low ventilation rates, combined with the growing evidence of the positive impact that sufficient ventilation has on human performance, suggests an opportunity for improving design and management of school facilities.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17100667     DOI: 10.1111/j.1600-0668.2006.00440.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  11 in total

1.  A holistic approach for the assessment of the indoor environmental quality, student productivity, and energy consumption in primary schools.

Authors:  Paraskevi Vivian Dorizas; Margarita-Niki Assimakopoulos; Mattheos Santamouris
Journal:  Environ Monit Assess       Date:  2015-04-16       Impact factor: 2.513

2.  Evaluation of microbiological air quality and of microclimate in university classrooms.

Authors:  Pietro Grisoli; Marinella Rodolfi; Tiziana Chiara; Laura Attinia Zonta; Cesare Dacarro
Journal:  Environ Monit Assess       Date:  2011-07-28       Impact factor: 2.513

3.  Formaldehyde Levels in Traditional and Portable Classrooms: A Pilot Investigation.

Authors:  Isabela C Ribeiro; Peter J Kowalski; David B Callahan; Gary P Noonan; Daphne B Moffett; David R Olson; Josephine Malilay
Journal:  J Environ Health       Date:  2016-03       Impact factor: 1.179

4.  PM Origin or Exposure Duration? Health Hazards from PM-Bound Mercury and PM-Bound PAHs among Students and Lecturers.

Authors:  Grzegorz Majewski; Kamila Widziewicz; Wioletta Rogula-Kozłowska; Patrycja Rogula-Kopiec; Karolina Kociszewska; Tomasz Rozbicki; Małgorzata Majder-Łopatka; Mariusz Niemczyk
Journal:  Int J Environ Res Public Health       Date:  2018-02-12       Impact factor: 3.390

5.  Indoor and outdoor monitoring of volatile organic compounds in school buildings: indicators based on health risk assessment to single out critical issues.

Authors:  Gianluigi de Gennaro; Genoveffa Farella; Annalisa Marzocca; Antonio Mazzone; Maria Tutino
Journal:  Int J Environ Res Public Health       Date:  2013-11-25       Impact factor: 3.390

6.  Indoor air quality in Brazilian universities.

Authors:  Sonia R Jurado; Antônia D P Bankoff; Andrea Sanchez
Journal:  Int J Environ Res Public Health       Date:  2014-07-11       Impact factor: 3.390

7.  Public Health Stops at the School House Door.

Authors:  Jerome A Paulson; Claire L Barnett
Journal:  Environ Health Perspect       Date:  2016-10-01       Impact factor: 9.031

8.  Association of classroom ventilation with reduced illness absence: a prospective study in California elementary schools.

Authors:  M J Mendell; E A Eliseeva; M M Davies; M Spears; A Lobscheid; W J Fisk; M G Apte
Journal:  Indoor Air       Date:  2013-04-22       Impact factor: 5.770

9.  ATP as a marker for surface contamination of biological origin in schools and as a potential approach to the measurement of cleaning effectiveness.

Authors:  Richard J Shaughnessy; Eugene C Cole; Demetrios Moschandreas; Ulla Haverinen-Shaughnessy
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

10.  Sick building syndrome and perceived indoor environmental quality: A survey of apartment buildings in Hong Kong.

Authors:  Siu-Kei Wong; Lawrence Wai-Chung Lai; Daniel Chi-Wing Ho; Kwong-Wing Chau; Cindy Lo-Kuen Lam; Chris Hung-Fai Ng
Journal:  Habitat Int       Date:  2009-04-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.