Literature DB >> 23611158

ATP as a marker for surface contamination of biological origin in schools and as a potential approach to the measurement of cleaning effectiveness.

Richard J Shaughnessy1, Eugene C Cole, Demetrios Moschandreas, Ulla Haverinen-Shaughnessy.   

Abstract

To address the need for a quantitative approach to the measurement of cleaning effectiveness, related to biologically derived surface contamination, three commercially available adenosine triphosphate (ATP) test systems were used to collect multiple samples measured in relative light units (RLUs) from 27 elementary schools in the southwestern United States before and after a standardized cleaning protocol. The database consisted of 6480 ATP measurements from four critical surfaces (student desktops, cafeteria tabletops, and restroom sinks and stall doors). Data was assessed according to ranges of ATP values before and after cleaning. Results showed the potential for such data to provide the basis for a standardized approach to the measurement of cleaning effectiveness, based on detection and quantification of pollutant loads of biological origin, across critical surfaces in school building environments. It is anticipated that verification of this data in school buildings across different geographic and climatic regions will lead to the establishment of "acceptable" ranges of ATP values that can be used as a practice-based approach to improving cleaning practices and contributing to healthier school environments.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23611158     DOI: 10.1080/15459624.2013.784633

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  11 in total

1.  How we didn't clean up until we washed our hands: shigellosis in an elementary and middle school in North Texas.

Authors:  Joann M Schulte; Linda Williams; Jawaid Asghar; Thi Dang; Shelby Bedwell; Kenzi Guerrero; Doug Hamaker; Shelley Stonecipher; James Zoretic; Catherine Chow
Journal:  South Med J       Date:  2012-01       Impact factor: 0.954

Review 2.  Significance of fomites in the spread of respiratory and enteric viral disease.

Authors:  Stephanie A Boone; Charles P Gerba
Journal:  Appl Environ Microbiol       Date:  2007-01-12       Impact factor: 4.792

3.  Assessment of hygienic quality of surfaces in retail food service establishments based on microbial counts and real-time detection of ATP.

Authors:  Annette E Cunningham; Raj Rajagopal; Jim Lauer; Paul Allwood
Journal:  J Food Prot       Date:  2011-04       Impact factor: 2.077

4.  MRSA as a health concern in athletic facilities.

Authors:  Karen S Hostetter; Mary Lux; Kyna Shelley; Jan L Drummond; Patti Laguna
Journal:  J Environ Health       Date:  2011 Jul-Aug       Impact factor: 1.179

5.  Association between substandard classroom ventilation rates and students' academic achievement.

Authors:  U Haverinen-Shaughnessy; D J Moschandreas; R J Shaughnessy
Journal:  Indoor Air       Date:  2010-10-28       Impact factor: 5.770

6.  A longitudinal study of sick building syndrome among pupils in relation to microbial components in dust in schools in China.

Authors:  Xin Zhang; Zhuohui Zhao; Tobias Nordquist; Lennart Larsson; Aleksandra Sebastian; Dan Norback
Journal:  Sci Total Environ       Date:  2011-09-23       Impact factor: 7.963

7.  Trial to control an outbreak of Panton-Valentine leukocidin-positive methicillin-resistant Staphylococcus aureus at a boarding school in Japan.

Authors:  Masaaki Higashiyama; Teruyo Ito; Xiao Han; Junichiro Nishiyama; Akemi Tanno; Toshiko Wada; Youichi Funaoka; Yusuke Yoshida; Kei Mikita; Tomomichi Ogawa; Yasushi Okusa; Koki Kaku; Junichi Hatada; Keiichi Hiramatsu; Akihiko Kawana
Journal:  Am J Infect Control       Date:  2011-06-12       Impact factor: 2.918

8.  Nasal patency and lavage biomarkers in relation to settled dust and cleaning routines in schools.

Authors:  R Wålinder; D Norbäck; G Wieslander; G Smedje; C Erwall; P Venge
Journal:  Scand J Work Environ Health       Date:  1999-04       Impact factor: 5.024

9.  Comparative studies of hand disinfection and handwashing procedures as tested by pupils in intervention programs.

Authors:  Inge Nandrup-Bus
Journal:  Am J Infect Control       Date:  2011-08       Impact factor: 2.918

10.  A preliminary study on the association between ventilation rates in classrooms and student performance.

Authors:  R J Shaughnessy; U Haverinen-Shaughnessy; A Nevalainen; D Moschandreas
Journal:  Indoor Air       Date:  2006-12       Impact factor: 5.770

View more
  4 in total

1.  Building and indoor environmental quality assessment of Nigerian primary schools: A pilot study.

Authors:  Oluyemi Toyinbo; Wanda Phipatanakul; Richard Shaughnessy; Ulla Haverinen-Shaughnessy
Journal:  Indoor Air       Date:  2019-03-20       Impact factor: 5.770

2.  Use of ATP Readings to Predict a Successful Hygiene Intervention in the Workplace to Reduce the Spread of Viruses on Fomites.

Authors:  Laura Y Sifuentes; Sonia L M Fankem; Kelly Reynolds; Akrum H Tamimi; Charles P Gerba; David Koenig
Journal:  Food Environ Virol       Date:  2016-08-18       Impact factor: 2.778

3.  Effects of classroom cleaning on student health: a longitudinal study.

Authors:  Richard Shaughnessy; Mark Hernandez; Ulla Haverinen-Shaughnessy
Journal:  J Expo Sci Environ Epidemiol       Date:  2022-04-04       Impact factor: 6.371

4.  Response to coronavirus disease 2019: Case study of one baking industry in Dhaka, Bangladesh.

Authors:  Md Fahad Jubayer; Md Shahidullah Kayshar; Md Al Emran; Md Nasir Uddin; Md Janibul Alam Soeb
Journal:  J Agric Food Res       Date:  2020-10-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.