Literature DB >> 17089836

Experimental determination of the effect of detector size on profile measurements in narrow photon beams.

E Pappas1, T G Maris, A Papadakis, F Zacharopoulou, J Damilakis, N Papanikolaou, N Gourtsoyiannis.   

Abstract

The aim of this work is to investigate experimentally the detector size effect on narrow beam profile measurements. Polymer gel and magnetic resonance imaging dosimetry was used for this purpose. Profile measurements (Pm(s)) of a 5 mm diameter 6 MV stereotactic beam were performed using polymer gels. Eight measurements of the profile of this narrow beam were performed using correspondingly eight different detector sizes. This was achieved using high spatial resolution (0.25 mm) two-dimensional measurements and eight different signal integration volumes A X A X slice thickness, simulating detectors of different size. "A" ranged from 0.25 to 7.5 mm, representing the detector size. The gel-derived profiles exhibited increased penumbra width with increasing detector size, for sizes >0.5 mm. By extrapolating the gel-derived profiles to zero detector size, the true profile (Pt) of the studied beam was derived. The same polymer gel data were also used to simulate a small-volume ion chamber profile measurement of the same beam, in terms of volume averaging. The comparison between these results and actual corresponding small-volume chamber profile measurements performed in this study, reveal that the penumbra broadening caused by both volume averaging and electron transport alterations (present in actual ion chamber profile measurements) is a lot more intense than that resulted by volume averaging effects alone (present in gel-derived profiles simulating ion chamber profile measurements). Therefore, not only the detector size, but also its composition and tissue equivalency is proved to be an important factor for correct narrow beam profile measurements. Additionally, the convolution kernels related to each detector size and to the air ion chamber were calculated using the corresponding profile measurements (Pm(s)), the gel-derived true profile (Pt), and convolution theory. The response kernels of any desired detector can be derived, allowing the elimination of the errors associated with narrow beam profile measurements.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17089836     DOI: 10.1118/1.2349691

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators.

Authors:  Christopher Fox; Tom Simon; Bill Simon; James F Dempsey; Darren Kahler; Jatinder R Palta; Chihray Liu; Guanghua Yan
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

3.  Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.

Authors:  Massimo Pasquino; Claudia Cutaia; Lorenzo Radici; Serena Valzano; Eva Gino; Carlo Cavedon; Michele Stasi
Journal:  Br J Radiol       Date:  2016-11-09       Impact factor: 3.039

4.  Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings.

Authors:  Henry Finlay Godson; M Ravikumar; S Sathiyan; K M Ganesh; Y Retna Ponmalar; C Varatharaj
Journal:  J Med Phys       Date:  2016 Jan-Mar

5.  Application of high field magnetic resonance microimaging in polymer gel dosimetry.

Authors:  Agnieszka Skorupa; Aleksandra Woźnica; Mateusz Ciszek; Michał Staniszewski; Marek Kijonka; Marek Kozicki; Bożena Woźniak; Andrzej Orlef; Andrzej Polański; Łukasz Boguszewicz; Maria Sokół
Journal:  Med Phys       Date:  2020-05-15       Impact factor: 4.071

6.  Corrections of photon beam profiles of small fields measured with ionization chambers using a three-layer neural network.

Authors:  Ann-Britt Schönfeld; Karl Mund; Guanghua Yan; Andreas Alexander Schönfeld; Hui Khee Looe; Björn Poppe
Journal:  J Appl Clin Med Phys       Date:  2021-10-11       Impact factor: 2.102

7.  Comparative Study between Measurement Data and Treatment Planning System (TPS) in Small Fields for High Energy Photon Beams.

Authors:  Khaled El Shahat; Aziza El Saeid; Ehab Attalla; Adel Yassin
Journal:  ISRN Oncol       Date:  2014-05-06

8.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.