Literature DB >> 17080415

A statistical comparison of pad numbers versus pad weights in the quantification of urinary incontinence.

Drew A Dylewski1, Margaret G Jamison, Kristy M Borawski, Neil D Sherman, Cindy L Amundsen, George D Webster.   

Abstract

AIMS: Pad per day (PPD) usage is a frequently utilized measure of urinary incontinence. The 24-hour pad weight test (24PWT) is a reproducible test for quantifying incontinence volumes. We investigated whether PPD validly reports the magnitude of urinary incontinence.
METHODS: This was a retrospective review of patients undergoing stress incontinence surgery from July 2002 to 2005. Inclusion criteria were a documented 24PWT and patient-reported PPD usage. Grams of urine loss per pad (GPP) provided a third measure of incontinence. Descriptive statistics and correlations between all variables and significance were noted. Factor analysis was performed on the three measures of leakage and age for all patients over age 50.
RESULTS: One hundred forty-five male and 116 female patients met inclusion criteria. Correlated against 24PWT, GPP has the strongest association with a correlation of 0.80 for males and 0.88 for females. PPD has a weaker correlation of 0.64 for males and 0.61 for females (R2 = 0.38 overall). Factor analysis identified two components associated with incontinence. A "leakage" component correlated best with 24PWT and GPP. Additionally, an "age" component implies that despite stable 24PWT values, older patients increase GPP while PPD decreases.
CONCLUSIONS: Self-reported PPD is an unreliable measure of incontinence as this variable only measures 38% of the variation of urinary incontinence volume. Patients at a given PPD level present with a wide range of 24PWT values. Older patients have higher per-pad leakage. Future incontinence studies should report 24PWT to ensure the most reliable and uniform data. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17080415     DOI: 10.1002/nau.20352

Source DB:  PubMed          Journal:  Neurourol Urodyn        ISSN: 0733-2467            Impact factor:   2.696


  17 in total

Review 1.  Normal lower urinary tract assessment in women: I. Uroflowmetry and post-void residual, pad tests, and bladder diaries.

Authors:  Tala Al Afraa; Wally Mahfouz; Lysanne Campeau; Jacques Corcos
Journal:  Int Urogynecol J       Date:  2011-09-21       Impact factor: 2.894

2.  Discrepancies in perception of urinary incontinence between patient and physician after robotic radical prostatectomy.

Authors:  Seung Ryeol Lee; Hong Wook Kim; Jae Won Lee; Woo Ju Jeong; Koon Ho Rha; Jang Hwan Kim
Journal:  Yonsei Med J       Date:  2010-11       Impact factor: 2.759

3.  Self-reported pad use per day reflects patient quality of life after pubovaginal sling surgery.

Authors:  John T Stoffel; Gjange Smith; Simone Crivellaro; John J Smith; John F Bresette
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2009-07-01

Review 4.  Comprehensive approach for post-prostatectomy incontinence in the era of robot-assisted radical prostatectomy.

Authors:  Nobuhiro Haga; Ruriko Takinami; Ryo Tanji; Akifumi Onagi; Kanako Matsuoka; Tomoyuki Koguchi; Hidenori Akaihata; Junya Hata; Soichiro Ogawa; Masao Kataoka; Yuichi Sato; Kei Ishibashi; Ken Aikawa; Yoshiyuki Kojima
Journal:  Fukushima J Med Sci       Date:  2017-07-26

5.  Pelvic floor muscle function is an independent predictor of outcome after retrourethral transobturator male sling procedure.

Authors:  Irina Soljanik; Ricarda M Bauer; Christian G Stief; Christian Gozzi; Armin J Becker
Journal:  World J Urol       Date:  2014-10-14       Impact factor: 4.226

6.  Validity testing of the stopwatch urine stream interruption test in radical prostatectomy patients.

Authors:  Joanne P Robinson; Sherry A Burrell; Tamara Avi-Itzhak; Ruth McCorkle
Journal:  J Wound Ostomy Continence Nurs       Date:  2012 Sep-Oct       Impact factor: 1.741

7.  Evaluation of Incontinence after Robot-Assisted Laparoscopic Radical Prostatectomy: Using the International Consultation on Incontinence Modular Questionnaire Short Form and Noting the Number of Safety Pads Needed by Japanese Patients.

Authors:  Katsuya Hikita; Masashi Honda; Bunya Kawamoto; Panagiota Tsounapi; Kuniyasu Muraoka; Takehiro Sejima; Atsushi Takenaka
Journal:  Yonago Acta Med       Date:  2017-03-09       Impact factor: 1.641

8.  Is there an urban-rural-gradient in patients with urinary incontinence?

Authors:  Sebastian Wille; Kawa Katarzyna; Ulrike Ahrens; Okyaz Eminaga; Udo Engelmann; Paas Jenny
Journal:  Can Urol Assoc J       Date:  2014 Mar-Apr       Impact factor: 1.862

9.  An inelastic retropubic suburethral sling in women with intrinsic sphincter deficiency.

Authors:  Alfredo Jijon; Aparna Hegde; Beatriz Arias; Vivian Aguilar; G Willy Davila
Journal:  Int Urogynecol J       Date:  2012-12-11       Impact factor: 2.894

Review 10.  Narrative review of male urethral sling for post-prostatectomy stress incontinence: sling type, patient selection, and clinical applications.

Authors:  Raevti Bole; Kevin J Hebert; Harrison C Gottlich; Elizabeth Bearrick; Tobias S Kohler; Boyd R Viers
Journal:  Transl Androl Urol       Date:  2021-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.