Literature DB >> 17058008

Membrane filtration - atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples.

Mustafa Soylak1, Umit Divrikli, Sibel Saracoglu, Latif Elci.   

Abstract

Cellulose nitrate membrane filter was used for the preconcentration-separation of Cu, Co, Cd, Pb and Cr ions. The analyte ions were collected on the membrane filter by the aid of carmine. Then membrane filter was dissolved by using nitric acid. The levels of the analytes in the final solutions were determined by flame atomic absorption spectrometry (FAAS). The analytical parameters including pH, amounts of carmine, sample volumes etc. have been optimized. No influences have been observed from the matrix ions. The detection limits for analytes were in the range of 0.08 microg/l-0.93 microg/l. The validation of the procedure was checked by the analysis of standard reference sediment (GBW 07309). The present method has been successfully applied for the FAAS determinations of analyte ions in real samples including black tea and magnesium salts.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17058008     DOI: 10.1007/s10661-006-9271-0

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  14 in total

1.  On-line preconcentration/determination of lead in Ilex paraguariensis samples (mate tea) using polyurethane foam as filter and USN-ICP-OES.

Authors:  P F Marchisio; A Sales; S Cerutti; E Marchevski; L D Martinez
Journal:  J Hazard Mater       Date:  2005-09-30       Impact factor: 10.588

2.  Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry.

Authors:  S L C Ferreira; W N L dos Santos; M A Bezerra; V A Lemos; J M Bosque-Sendra
Journal:  Anal Bioanal Chem       Date:  2003-01-29       Impact factor: 4.142

3.  Collection of iron(III) from homogeneous aqueous solutions on membrane filters using Chromazurol B with Triton X-100.

Authors:  Kazuaki Ihara; Shin-ichi Hasegawa; Kunishige Naito
Journal:  Anal Sci       Date:  2003-02       Impact factor: 2.081

4.  Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANC.

Authors:  Ednilton Moreira Gama; Adriana da Silva Lima; Valfredo Azevedo Lemos
Journal:  J Hazard Mater       Date:  2006-03-13       Impact factor: 10.588

5.  [Determination of trace nickel in coal gangue by catalytic fading spectrophotometry].

Authors:  L Q Wang; J Q Li; Y L Deng
Journal:  Guang Pu Xue Yu Guang Pu Fen Xi       Date:  2001-10       Impact factor: 0.589

6.  Preliminary results on the determination of ultratrace amounts of cadmium in tea samples using a flow injection on-line solid phase extraction separation and preconcentration technique to couple with a sequential injection hydride generation atomic fluorescence spectrometry.

Authors:  Taicheng Duan; Xuejie Song; Dan Jin; Hongfei Li; Jingwei Xu; Hangting Chen
Journal:  Talanta       Date:  2005-10-31       Impact factor: 6.057

7.  Solid phase extraction preconcentration of cobalt and nickel with 5,7-dichloroquinone-8-ol embedded styrene-ethylene glycol dimethacrylate polymer particles and determination by flame atomic absorption spectrometry (FAAS).

Authors:  R S Praveen; Sobhi Daniel; T Prasada Rao
Journal:  Talanta       Date:  2005-01-04       Impact factor: 6.057

8.  Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper.

Authors:  Valfredo Azevedo Lemos; Patrícia Xavier Baliza
Journal:  Talanta       Date:  2005-04-18       Impact factor: 6.057

9.  Factorial design for multivariate optimization of an on-line preconcentration system for platinum determination by ultrasonic nebulization coupled to inductively coupled plasma optical emission spectrometry.

Authors:  S Cerutti; J A Salonia; S L C Ferreira; R A Olsina; L D Martinez
Journal:  Talanta       Date:  2004-07-08       Impact factor: 6.057

10.  Preconcentration of Cr(III), Co(II), Cu(II), Fe(III) and Pb(II) as calmagite chelates on cellulose nitrate membrane filter prior to their flame atomic absorption spectrometric determinations.

Authors:  M Soylak; U Divrikli; L Elci; M Dogan
Journal:  Talanta       Date:  2002-03-04       Impact factor: 6.057

View more
  6 in total

1.  Application of nanoclay for preconcentration of ultra trace amounts of palladium in environmental samples prior to its determination by ETAAS.

Authors:  Mohammad Ali Taher; Nezhat Jandaghi; Hamid Fazelirad; Hamid Ashkenani
Journal:  Environ Monit Assess       Date:  2014-03       Impact factor: 2.513

2.  Ultrasound-assisted ionic liquid-based dispersive liquid-liquid microextraction for preconcentration of patent blue V and its determination in food samples by UV-visible spectrophotometry.

Authors:  Yunus Emre Unsal; Mustafa Soylak; Mustafa Tuzen
Journal:  Environ Monit Assess       Date:  2015-03-24       Impact factor: 2.513

3.  Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate.

Authors:  Mehmet Tufekci; Volkan Numan Bulut; Hamide Elvan; Duygu Ozdes; Mustafa Soylak; Celal Duran
Journal:  Environ Monit Assess       Date:  2012-04-25       Impact factor: 2.513

4.  Synthesis, Characterization and Applications of Schiff Base Chemosensor for Determination of Cr(III) Ions.

Authors:  Sikandar Khan; Mian Muhammad; Jari S Algethami; Hamed M Al-Saidi; Albandary Almahri; Athar Abdulfattah Hassanian
Journal:  J Fluoresc       Date:  2022-06-24       Impact factor: 2.525

5.  Determination of copper in biological samples by flame atomic absorption spectrometry after precipitation with Me-BTAP.

Authors:  Valfredo A Lemos; Geisiane dos S Novaes; Anaildes L de Carvalho; Ednilton M Gama; Aldenor G Santos
Journal:  Environ Monit Assess       Date:  2008-01-31       Impact factor: 2.513

6.  Determination of ultra-trace amounts of cadmium by ET-AAS after column preconcentration with a new sorbent of modified MWCNTs.

Authors:  Mohadeseh Madadizadeh; Mohammad Ali Taher; Hamid Ashkenani
Journal:  Environ Monit Assess       Date:  2012-09-01       Impact factor: 2.513

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.