Literature DB >> 22527456

Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate.

Mehmet Tufekci1, Volkan Numan Bulut, Hamide Elvan, Duygu Ozdes, Mustafa Soylak, Celal Duran.   

Abstract

A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)-diethyldithiocarbamate-(Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1-2.2 μg L(-1) while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22527456     DOI: 10.1007/s10661-012-2618-9

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  23 in total

1.  Determination of chromium, copper and lead in river water by graphite-furnace atomic absorption spectrometry after coprecipitation with terbium hydroxide.

Authors:  Tomoharu Minami; Yoshiki Sohrin; Joichi Ueda
Journal:  Anal Sci       Date:  2005-12       Impact factor: 2.081

2.  Determination of trace amounts of some metals in samples with high salt content by atomic absorption spectrometry after cobalt-diethyldithiocarbamate coprecipitation.

Authors:  L Elçi; U Sahin; S Oztaş
Journal:  Talanta       Date:  1997-06       Impact factor: 6.057

3.  Copper(II)-rubeanic acid coprecipitation system for separation-preconcentration of trace metal ions in environmental samples for their flame atomic absorption spectrometric determinations.

Authors:  Mustafa Soylak; Nilgun D Erdogan
Journal:  J Hazard Mater       Date:  2006-05-02       Impact factor: 10.588

4.  SP70-alpha-benzoin oxime chelating resin for preconcentration-separation of Pb(II), Cd(II), Co(II) and Cr(III) in environmental samples.

Authors:  Ibrahim Narin; Yavuz Surme; Erdogan Bercin; Mustafa Soylak
Journal:  J Hazard Mater       Date:  2006-11-07       Impact factor: 10.588

5.  Membrane filtration - atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples.

Authors:  Mustafa Soylak; Umit Divrikli; Sibel Saracoglu; Latif Elci
Journal:  Environ Monit Assess       Date:  2006-10-21       Impact factor: 2.513

6.  Preconcentration, separation and spectrophotometric determination of aluminium(III) in water samples and dialysis concentrates at trace levels with 8-hydroxyquinoline-cobalt(II) coprecipitation system.

Authors:  Volkan Numan Bulut; Deniz Arslan; Duygu Ozdes; Mustafa Soylak; Mehmet Tufekci
Journal:  J Hazard Mater       Date:  2010-06-16       Impact factor: 10.588

7.  Optimization and determination of Cd (II) in different environmental water samples with dispersive liquid-liquid microextraction preconcentration combined with inductively coupled plasma optical emission spectrometry.

Authors:  Maryam Salahinejad; Fereydoon Aflaki
Journal:  Environ Monit Assess       Date:  2010-07-23       Impact factor: 2.513

8.  Carrier element-free coprecipitation with 3-phenly-4-o-hydroxybenzylidenamino-4,5-dihydro-1,2,4-triazole-5-one for separation/preconcentration of Cr(III), Fe(III), Pb(II) and Zn(II) from aqueous solutions.

Authors:  Celal Duran; Volkan N Bulut; Ali Gundogdu; Duygu Ozdes; Nuri Yildirim; Mustafa Soylak; H Basri Senturk; Latif Elci
Journal:  J Hazard Mater       Date:  2008-12-31       Impact factor: 10.588

9.  Utilization of membrane filtration for preconcentration and determination of Cu(II) and Pb(II) in food, water and geological samples by atomic absorption spectrometry.

Authors:  Mustafa Soylak; Yunus Emre Unsal; Nebiye Kizil; Ayse Aydin
Journal:  Food Chem Toxicol       Date:  2009-11-11       Impact factor: 6.023

10.  Cloud point extraction for the determination of copper, nickel and cobalt ions in environmental samples by flame atomic absorption spectrometry.

Authors:  M Ghaedi; A Shokrollahi; F Ahmadi; H R Rajabi; M Soylak
Journal:  J Hazard Mater       Date:  2007-05-16       Impact factor: 10.588

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.