Literature DB >> 16530947

Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANC.

Ednilton Moreira Gama1, Adriana da Silva Lima, Valfredo Azevedo Lemos.   

Abstract

In this work, polyurethane foam (PUF) loaded with 2-(6'-methyl-2'-benzothiazolylazo)chromotropic acid (Me-BTANC) was packed in a minicolumn and it was used in an on-line preconcentration system for cadmium and lead determination. Optimum hydrodynamic and chemical conditions for metal sorption were investigated. The effects of several foreign substances on the adsorption of cadmium and lead were also reported. The enrichment factor obtained was 37 (Cd and Pb) for 180 s preconcentration time. The proposed procedures allowed the determination of metals with detection limits (3 sigma) of 0.80 and 3.75 microg L(-1) (0.10 and 0.47 microg g(-1) of solid sample) for cadmium and lead, respectively. The precision of the procedures was also calculated: 3.1 (Cd 10 microg L(-1)) and 4.4% (Pb 100 microg L(-1)). The accuracy of the procedure was checked by analysis of the certified reference materials Spinach Leaves and Fish Tissue. Cadmium and lead contents in environmental samples (black tea, spinach leaves, natural and tap water) were determined by applying the proposed procedure.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16530947     DOI: 10.1016/j.jhazmat.2006.01.015

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  7 in total

1.  Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

Authors:  Sadaf S Arain; Tasneem G Kazi; Asma J Arain; Hassan I Afridi; Muhammad B Arain; Kapil D Brahman; Abdul H Panhwar; Mariam S Arain
Journal:  Environ Sci Pollut Res Int       Date:  2015-04-23       Impact factor: 4.223

Review 2.  Determination of cadmium and lead in human biological samples by spectrometric techniques: a review.

Authors:  Valfredo Azevedo Lemos; Anaildes Lago de Carvalho
Journal:  Environ Monit Assess       Date:  2009-12-22       Impact factor: 2.513

3.  An online preconcentration system for the determination of uranium in water and effluent samples.

Authors:  Valfredo Azevedo Lemos; Ednilton Moreira Gama
Journal:  Environ Monit Assess       Date:  2009-12-16       Impact factor: 2.513

4.  Application of 1-(2-pyridylazo)-2-naphthol-modified nanoporous silica as a technique in simultaneous trace monitoring and removal of toxic heavy metals in food and water samples.

Authors:  Jafar Abolhasani; Mohammad Behbahani
Journal:  Environ Monit Assess       Date:  2014-12-12       Impact factor: 2.513

5.  Membrane filtration - atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples.

Authors:  Mustafa Soylak; Umit Divrikli; Sibel Saracoglu; Latif Elci
Journal:  Environ Monit Assess       Date:  2006-10-21       Impact factor: 2.513

6.  Enhanced adsorptive composite foams for copper (II) removal utilising bio-renewable polyisoprene-functionalised carbon derived from coconut shell waste.

Authors:  Wachiraporn Kettum; Chanatip Samart; Narong Chanlek; Phakkhananan Pakawanit; Prasert Reubroycharoen; Guoqing Guan; Suwadee Kongparakul; Suda Kiatkamjornwong
Journal:  Sci Rep       Date:  2021-01-14       Impact factor: 4.379

7.  Selective aptamer conjugation to silver-coated magnetite nanoparticles for magnetic solid-phase extraction of trace amounts of Pb2+ ions.

Authors:  Sara Rahnama; Shahab Shariati; Faten Divsar
Journal:  RSC Adv       Date:  2021-01-27       Impact factor: 3.361

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.