A plastic scintillation dosimeter for high dose rate brachytherapy.

J Lambert1, D R McKenzie, S Law, J Elsey, N Suchowerska.   

Abstract

In vivo dose verification in brachytherapy requires a small insertable dosimeter with a real-time readout capability. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are one of the most promising dosimeters for this application. We have developed two sizes of the BrachyFOD scintillation dosimeter which have external diameters of 2.2 mm and 1 mm and have determined their important dosimetric characteristics (depth dose relation, angular dependence, temperature dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries using an (192)Ir source from an HDR brachytherapy unit. The dosimeter design enables readout at less than 0.5 s intervals. The BrachyFOD satisfies the need for a real-time in vivo brachytherapy dosimeter.

Mesh:

Substances:

Year:  2006        PMID: 17047266     DOI: 10.1088/0031-9155/51/21/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.

Authors:  Lilie L W Wang; David Klein; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy.

Authors:  François Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

4.  An investigation of a PRESAGE® in vivo dosimeter for brachytherapy.

Authors:  A K Vidovic; T Juang; S Meltsner; J Adamovics; J Chino; B Steffey; O Craciunescu; M Oldham
Journal:  Phys Med Biol       Date:  2014-06-24       Impact factor: 3.609

5.  Technical note: removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: a relevant and necessary step.

Authors:  Francois Therriault-Proulx; Sam Beddar; Tina M Briere; Louis Archambault; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.

Authors:  Mathieu Guillot; Luc Gingras; Louis Archambault; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

7.  Simulation of the precision limits of plastic scintillation detectors using optimal component selection.

Authors:  Frédéric Lacroix; Luc Beaulieu; Louis Archambault; A Sam Beddar
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

8.  A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.

Authors:  Francois Therriault-Proulx; Tina M Briere; Firas Mourtada; Sylviane Aubin; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

9.  A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization.

Authors:  Frédéric Lacroix; A Sam Beddar; Mathieu Guillot; Luc Beaulieu; Luc Gingras
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

10.  Evaluating the performance of TG-43 protocol in esophageal HDR brachytherapy viewpoint to trachea inhomogeneity.

Authors:  Seyed Mohsen Hosseini Daghigh; Hamid Reza Baghani; Seyed Mahmoud Reza Aghamiri; Seyed Rabi Mahdavi
Journal:  Rep Pract Oncol Radiother       Date:  2017-05-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.