Validation of sonotubometry in healthy adults.

S J C van der Avoort1, N van Heerbeek, G A Zielhuis, C W R J Cremers.   

Abstract

BACKGROUND: Frequent active opening of the eustachian tube (ET) allows ventilation of the middle ear and equilibration of pressure changes. Active opening is accomplished by the contraction of the paratubal muscles during swallowing. Because a disturbance of the ventilatory function of the ET may contribute to the development of otitis media with effusion, it is important to investigate ET function. Sonotubometry can be used to detect whether the ET can open or not during swallowing acts.
METHODS: We developed a sonotubometer to test ET ventilatory function in 36 healthy adults. The width of the test signal frequency was between 5500 and 8500 Hz (centre frequency of 7000 Hz) and the loudness was 95 dB. To test reproducibility, testing took place in two sessions of 10 swallowing acts each.
RESULTS: Opening of the ET could be registered in 91.6 per cent of the subjects in at least one of the two measurements. The first and the second measurements were highly correlated, with a Spearman's coefficient of 0.907.
CONCLUSION: We confirmed that there is generally a good ventilatory ET function in otologically healthy adults, although, in a few cases, ET opening was not registered. Furthermore, we confirmed that our sonometric test equipment had acceptable reproducibility. Sonotubometry is a promising method for assessing ventilatory ET function. Research is ongoing to test the discriminative power of sonotubometry in children with various otological conditions.

Entities:  

Mesh:

Year:  2006        PMID: 17038231     DOI: 10.1017/S0022215106001095

Source DB:  PubMed          Journal:  J Laryngol Otol        ISSN: 0022-2151            Impact factor:   1.469


  5 in total

1.  A method to assess the accuracy of sonotubometry for detecting Eustachian tube openings.

Authors:  J Douglas Swarts; Miriam S Teixeira; Juliane Banks; Jenna El-Wagaa; William J Doyle
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-04-08       Impact factor: 2.503

2.  Evaluation of Eustachian tube function with perfect sequences: technical realization and first clinical results.

Authors:  Ercole F N Di Martino; Viorel Nath; Aulis Telle; Christiane Antweiler; Leif E Walther; P Vary
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-09-01       Impact factor: 2.503

3.  Eustachian Tube Opening Measurement by Sonotubometry Using Perfect Sequences for Healthy Adults.

Authors:  Vilma Beleskiene; Eugenijus Lesinskas; Vaida Januskiene; Kristina Daunoraviciene; Darius Rauba; Justinas Ivaska
Journal:  Clin Exp Otorhinolaryngol       Date:  2016-04-19       Impact factor: 3.372

Review 4.  Advances in Eustachian tube function testing.

Authors:  Matthew E Smith; Manohar L Bance; James R Tysome
Journal:  World J Otorhinolaryngol Head Neck Surg       Date:  2019-10-11

5.  Revisiting the Diagnostic Performance of the Modified Nine-Step Test for Obstructive and Patulous Eustachian Tube Dysfunction.

Authors:  Seong Hoon Bae; Seojin Moon; Mincheol Jeong; In Seok Moon
Journal:  Diagnostics (Basel)       Date:  2022-03-17