Literature DB >> 24710849

A method to assess the accuracy of sonotubometry for detecting Eustachian tube openings.

J Douglas Swarts1, Miriam S Teixeira, Juliane Banks, Jenna El-Wagaa, William J Doyle.   

Abstract

Sonotubometry is a simple test for Eustachian tube (ET) opening during a maneuver. Different sonotubometry configurations were suggested to maximize test accuracy, but no method has been described for comparing sonotubometry test results with those for a definitive measure of ET opening. Here, we present such a method and exemplify is use by an accuracy assessment of a simple sonotubometry configuration. A total of 502 data-sequences from 168 test sessions in 103 adult subjects were analyzed. For each session, subjects were seated in a pressure chamber and relative middle ear over- and under-pressures created by changing chamber pressure. At each pressure, the test sequence of bilateral tympanometry, bilateral sonotubometry while the subject swallowed twice, and bilateral tympanometry was done. Tympanometric data were expressed as the fractional gradient equilibrated (FGE) by swallowing and sonotubometric signals were analyzed to record the shape of detected sound signals. Tympanometric and sonotubometric tubal opening assignments were analyzed by cross-correlation. For the data sequences with FGE = 0 (n = 32) evidencing no tubal opening and one (n = 249) evidencing definitive tubal opening, detection of a sonotubometry sound signal during a swallow had a sensitivity and specificity of 74.2 and 65.6 % for identifying ET openings and an accuracy of 73.3 % for assigning ET opening/non-opening by swallowing. Measures of sound signal shape were significantly different between those groups. This protocol allows a sonotubometry accuracy assessment for detecting ET openings. For the test configuration used, accuracy was moderate, but this should improve as more sophisticated sonotubometry test configurations are evaluated.

Entities:  

Mesh:

Year:  2014        PMID: 24710849      PMCID: PMC4190102          DOI: 10.1007/s00405-014-3031-5

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  25 in total

1.  Abnormal middle ear pressures during experimental influenza A virus infection--role of Eustachian tube function.

Authors:  W J Doyle; J T Seroky; B L Angelini; M Gulhan; D P Skoner; P Fireman
Journal:  Auris Nasus Larynx       Date:  2000-10       Impact factor: 1.863

2.  Sonotubometry with perfect sequences: First results in pathological ears.

Authors:  Deyan Rosenov Asenov; Viorel Nath; Aulis Telle; Christiane Antweiler; Leif Erik Walther; Peter Vary; Ercole F N Di Martino
Journal:  Acta Otolaryngol       Date:  2010-11       Impact factor: 1.494

3.  Measurement of Eustachian tube function.

Authors:  I Satoh; I Watanabe; T Sainoo
Journal:  Arch Otolaryngol       Date:  1970-10

4.  Eustachian tube function measured as pressure equilibration and sound transmission capacity. A comparison in healthy ears.

Authors:  L Andréasson; A Ivarsson; S Luttrup; B Möllerström; O Tjernström
Journal:  ORL J Otorhinolaryngol Relat Spec       Date:  1984       Impact factor: 1.538

5.  Interpretation of sonotubometry. A critical view of the acoustical measurement of the opening of the eustachian tube.

Authors:  T Lildholdt; T Brask; T Hvidegaard
Journal:  Acta Otolaryngol       Date:  1984 Sep-Oct       Impact factor: 1.494

6.  Sonometric evaluation of eustachian tube function using broadband stimuli.

Authors:  K G Murti; R M Stern; E I Cantekin; C D Bluestone
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  1980 May-Jun

7.  Classification of spectral patterns obtained from eustachian tube sonometry.

Authors:  K G Murti; R M Stern; E I Cantekin; C D Bluestone
Journal:  IEEE Trans Biomed Eng       Date:  1982-06       Impact factor: 4.538

8.  Comparative preoperative evaluation of eustachian tube function in pathological ears.

Authors:  H Virtanen; T Palva; T Jauhiainen
Journal:  Ann Otol Rhinol Laryngol       Date:  1980 Jul-Aug       Impact factor: 1.547

9.  Measurement of eustachian tube function using sonotubometry.

Authors:  J Holmquist; G Björkman; L Olén
Journal:  Scand Audiol       Date:  1981

10.  Sonotubometry. An acoustical method for objective measurement of auditory tubal opening.

Authors:  H Virtanen
Journal:  Acta Otolaryngol       Date:  1978 Jul-Aug       Impact factor: 1.494

View more
  6 in total

Review 1.  [The pressure-equalizing function of the Eustachian tube : Evaluation in a hypo-/hyperbaric pressure chamber].

Authors:  S Jansen; M F Meyer; K-B Hüttenbrink; D Beutner
Journal:  HNO       Date:  2017-08       Impact factor: 1.284

2.  Tubomanometry value as an associated factor for medication outcomes in adult acute otitis media with effusion.

Authors:  Junbo Zhang; Zhen Zhong; Shuifang Xiao; Yuhe Liu; Zhen Zhen; Lei Ren; Lei Zhang
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-10-26       Impact factor: 2.503

3.  Correlations between videoendoscopy and sonotubometry of eustachian tube opening during a swallow.

Authors:  Cuneyt M Alper; Miriam S Teixeira; J Douglas Swarts
Journal:  Laryngoscope       Date:  2016-03-24       Impact factor: 3.325

4.  Detection of eustachian tube openings by tubomanometry in adult otitis media with effusion.

Authors:  Panpan Liu; Kaiming Su; Bijun Zhu; Yaqin Wu; Haibo Shi; Shankai Yin
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-02-19       Impact factor: 2.503

5.  Interpretation of sonotubometric data based on phase-shift detection.

Authors:  Yaw Amoako-Tuffour; Philip Garland; Manohar Bance
Journal:  J Otolaryngol Head Neck Surg       Date:  2016-06-10

Review 6.  Advances in Eustachian tube function testing.

Authors:  Matthew E Smith; Manohar L Bance; James R Tysome
Journal:  World J Otorhinolaryngol Head Neck Surg       Date:  2019-10-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.