Literature DB >> 17037934

Measurement of ammonia in human breath with a liquid-film conductivity sensor.

Kei Toda1, Jianzhong Li, Purnendu K Dasgupta.   

Abstract

Measurement of breath NH3 is of interest in clinical applications as it can be used as a measure of kidney/liver functions as well as halitosis. We have developed a liquid-film conductivity sensor to measure NH3 in human breath. A film of dilute H2SO4 is formed on the top of two metal capillary tubes placed in a concentric annular arrangement. The tube exterior has been specially treated to render it hydrophilic. As breath passes over the sensor tip, the film collects NH3 and the solution conductivity (measured by the concentric capillaries functioning as electrodes) decreases accordingly. This initial rate of conductivity decrease was determined to be the best metric (most rapid and least dependent on breath pCO2) for ammonia, relative to time to attain complete neutralization (conductivity minimum) or the final rate of conductivity increase as more ammonia dissolves after neutralization. The absorbing solution composition was optimized so that CO2 does not interfere. Both dynamic measurement using mask sampling and offline balloon sampling were performed. Ammonia readily absorbs on surfaces when significant concentrations of water vapor are present. As such, memory effects are common when analyzing human breath for ammonia. This problem was successfully eliminated. The results from this sensor agreed well with data obtained by a solution-phase fluorometric technique using a porous membrane diffusion scrubber and o-phthalaldehyde derivatization chemistry. For breath CO2 measurement, the applicability of a similar sensor that relies on a NaOH film was also demonstrated.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17037934     DOI: 10.1021/ac060965m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  12 in total

1.  Proposed model for ONCHIT pre-case biosurveillance using multiple array sensing and non-invasive data capture.

Authors:  Richard Churchill; Daniel Lorence; Michael Richards
Journal:  J Med Syst       Date:  2009-04-24       Impact factor: 4.460

2.  Using multiple array sensing and non-invasive data capture as a model for polypharmacy error detection.

Authors:  Daniel Lorence; James Li
Journal:  J Med Syst       Date:  2011-05-13       Impact factor: 4.460

3.  A Handheld, Colorimetric Optoelectronic Dynamics Analyzer for Measuring Total Ammonia of Biological Samples.

Authors:  Nai-Yuan Liu; Pinar Cay-Durgun; Tianmiao Lai; Mark Sprowls; Leslie Thomas; Mary Laura Lind; Erica Forzani
Journal:  IEEE J Transl Eng Health Med       Date:  2018-07-05       Impact factor: 3.316

4.  Cobinamide-based cyanide analysis by multiwavelength spectrometry in a liquid core waveguide.

Authors:  Jian Ma; Purnendu K Dasgupta; William Blackledge; Gerry R Boss
Journal:  Anal Chem       Date:  2010-07-15       Impact factor: 6.986

Review 5.  Clinical practice: the management of hyperammonemia.

Authors:  Johannes Häberle
Journal:  Eur J Pediatr       Date:  2010-12-17       Impact factor: 3.183

6.  Breath-ammonia testing of healthy subjects and patients with cirrhosis.

Authors:  R Adrover; D Cocozzella; E Ridruejo; A García; J Rome; J J Podestá
Journal:  Dig Dis Sci       Date:  2011-08-13       Impact factor: 3.199

7.  Core-shell nanostructured hybrid composites for volatile organic compound detection.

Authors:  Tran Thanh Tung; Dusan Losic; Seung Jun Park; Jean-Francois Feller; TaeYoung Kim
Journal:  Int J Nanomedicine       Date:  2015-08-28

Review 8.  Technologies for Clinical Diagnosis Using Expired Human Breath Analysis.

Authors:  Thalakkotur Lazar Mathew; Prabhahari Pownraj; Sukhananazerin Abdulla; Biji Pullithadathil
Journal:  Diagnostics (Basel)       Date:  2015-02-02

9.  Halitosis: From diagnosis to management.

Authors:  Bahadır Uğur Aylıkcı; Hakan Colak
Journal:  J Nat Sci Biol Med       Date:  2013-01

Review 10.  Halitosis: Current concepts on etiology, diagnosis and management.

Authors:  Uditi Kapoor; Gaurav Sharma; Manish Juneja; Archna Nagpal
Journal:  Eur J Dent       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.