Literature DB >> 20560532

Cobinamide-based cyanide analysis by multiwavelength spectrometry in a liquid core waveguide.

Jian Ma1, Purnendu K Dasgupta, William Blackledge, Gerry R Boss.   

Abstract

A novel cyanide analyzer based on sensitive cobinamide chemistry relies on simultaneous reagent and sample injection and detection in a 50 cm liquid core waveguide (LCW) flow cell illuminated by a white light emitting diode. The transmitted light is read by a fiber-optic charge coupled device (CCD) spectrometer. Alkaline cobinamide (orange, lambda(max) = 510 nm) changes to violet (lambda(max) = 583 nm) upon reaction with cyanide. Multiwavelength detection permits built-in correction for artifact responses intrinsic to a single-line flow injection system and corrects for drift. With optimum choice of the reaction medium, flow rate, and mixing coil length, the limit of detection (LOD, S/N = 3) is 30 nM and the linear dynamic range extends to 10 microM. The response base width for 1% carryover is <95 s, permitting a throughput of 38 samples/h. The relative standard deviations (rsd) for repetitive determinations at 0.15, 0.5, and 1 microM were 7.6% (n = 5), 3.2% (n = 7), and 1.7% (n = 6), respectively. Common ions at 250-80,000x concentrations do not interfere except for sulfide. For the determination of 2 microM CN(-), the presence of 2, 5, 10, 20, 100, and 1000 microM HS(-) results in 22, 27, 48, 58, 88, and 154% overestimation of cyanide. The sulfide product actually has a different characteristic absorption, and in those samples where significant presence is likely, this can be corrected for. We demonstrate applicability by analyzing the hydrolytic cyanide extract of apple and pear seeds with orange seeds as control and also measure HCN in breath air samples. Spike recoveries in these sample extracts ranged from 91 to 108%.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20560532      PMCID: PMC2912415          DOI: 10.1021/ac101158d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  20 in total

1.  Cyanide detoxification by the cobalamin precursor cobinamide.

Authors:  Kate E Broderick; Prasanth Potluri; Shunhui Zhuang; Immo E Scheffler; Vijay S Sharma; Renate B Pilz; Gerry R Boss
Journal:  Exp Biol Med (Maywood)       Date:  2006-05

2.  A straightforward method for the colorimetric detection of endogenous biological cyanide.

Authors:  Christine Männel-Croisé; Benjamin Probst; Felix Zelder
Journal:  Anal Chem       Date:  2009-11-15       Impact factor: 6.986

3.  Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity.

Authors:  Tianshu Wang; Andriy Pysanenko; Kseniya Dryahina; Patrik Spaněl; David Smith
Journal:  J Breath Res       Date:  2008-09-08       Impact factor: 3.262

Review 4.  Sensors for the optical detection of cyanide ion.

Authors:  Zhaochao Xu; Xiaoqiang Chen; Ha Na Kim; Juyoung Yoon
Journal:  Chem Soc Rev       Date:  2009-09-04       Impact factor: 54.564

5.  New facile method to measure cyanide in blood.

Authors:  William C Blackledge; Charles W Blackledge; Alexa Griesel; Sari B Mahon; Matthew Brenner; Renate B Pilz; Gerry R Boss
Journal:  Anal Chem       Date:  2010-05-15       Impact factor: 6.986

6.  Nitric oxide scavenging by the cobalamin precursor cobinamide.

Authors:  Kate E Broderick; Veena Singh; Shunhui Zhuang; Amanpreet Kambo; Jeffrey C Chen; Vijay S Sharma; Renate B Pilz; Gerry R Boss
Journal:  J Biol Chem       Date:  2005-01-04       Impact factor: 5.157

7.  The concentration distributions of some metabolites in the exhaled breath of young adults.

Authors:  Patrik Spanel; Kseniya Dryahina; David Smith
Journal:  J Breath Res       Date:  2007-10-16       Impact factor: 3.262

8.  Acetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4-83 years.

Authors:  Patrik Spaněl; Kseniya Dryahina; David Smith
Journal:  J Breath Res       Date:  2007-09-04       Impact factor: 3.262

9.  Temperature dependence of Henry's law constant for hydrogen cyanide. Generation of trace standard gaseous hydrogen cyanide.

Authors:  Jian Ma; Purnendu K Dasgupta; William Blackledge; Gerry R Boss
Journal:  Environ Sci Technol       Date:  2010-04-15       Impact factor: 9.028

10.  Background levels of hydrogen cyanide in human breath measured by infrared cavity ring down spectroscopy.

Authors:  Kristin Stamyr; Olavi Vaittinen; Janne Jaakola; Joseph Guss; Markus Metsälä; Gunnar Johanson; Lauri Halonen
Journal:  Biomarkers       Date:  2009-08       Impact factor: 2.658

View more
  10 in total

1.  Effect of Ascorbate on the Cyanide-Scavenging Capability of Cobalt(III) meso-Tetra(4-N-methylpyridyl)porphine Pentaiodide: Deactivation by Reduction?

Authors:  Oscar S Benz; Quan Yuan; Andrea A Cronican; Jim Peterson; Linda L Pearce
Journal:  Chem Res Toxicol       Date:  2016-02-10       Impact factor: 3.739

2.  Comparison of a new cobinamide-based method to a standard laboratory method for measuring cyanide in human blood.

Authors:  Robert Swezey; Walter Shinn; Carol Green; David R Drover; Gregory B Hammer; Scott R Schulman; Anne Zajicek; David A Jett; Gerry R Boss
Journal:  J Anal Toxicol       Date:  2013-05-06       Impact factor: 3.367

3.  Rapid point of care analyzer for the measurement of cyanide in blood.

Authors:  Jian Ma; Shin-Ichi Ohira; Santosh K Mishra; Mahitti Puanngam; Purnendu K Dasgupta; Sari B Mahon; Matthew Brenner; William Blackledge; Gerry R Boss
Journal:  Anal Chem       Date:  2011-05-10       Impact factor: 6.986

4.  Cobinamide chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide.

Authors:  Jian Ma; Purnendu K Dasgupta; Felix H Zelder; Gerry R Boss
Journal:  Anal Chim Acta       Date:  2012-06-04       Impact factor: 6.558

5.  A disposable blood cyanide sensor.

Authors:  Yong Tian; Purnendu K Dasgupta; Sari B Mahon; Jian Ma; Matthew Brenner; Jian-Hua Wang; Gerry R Boss
Journal:  Anal Chim Acta       Date:  2013-02-01       Impact factor: 6.558

6.  Comment on "Rapid visual detection of blood cyanide" by C. Männel-Croisé and F. Zelder, Analytical Methods, 2012, 4, 2632.

Authors:  Akinde F Kadjo; Purnendu K Dasgupta; Gerry R Boss
Journal:  Anal Methods       Date:  2015-06-17       Impact factor: 2.896

7.  High performance liquid chromatography tandem mass spectrometry assay for the determination of cobinamide in pig plasma.

Authors:  Brent A McCracken; Matthew K Brittain
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-10-20       Impact factor: 3.205

8.  A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

Authors:  Qiyang Zhang; Naveen Maddukuri; Maojun Gong
Journal:  J Chromatogr A       Date:  2015-08-28       Impact factor: 4.759

9.  Development of a fluorescence-based sensor for rapid diagnosis of cyanide exposure.

Authors:  Randy Jackson; Robert P Oda; Raj K Bhandari; Sari B Mahon; Matthew Brenner; Gary A Rockwood; Brian A Logue
Journal:  Anal Chem       Date:  2014-01-16       Impact factor: 6.986

Review 10.  Cyanides in the environment-analysis-problems and challenges.

Authors:  Ewa Jaszczak; Żaneta Polkowska; Sylwia Narkowicz; Jacek Namieśnik
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-16       Impact factor: 4.223

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.