Literature DB >> 20703924

Proposed model for ONCHIT pre-case biosurveillance using multiple array sensing and non-invasive data capture.

Richard Churchill1, Daniel Lorence, Michael Richards.   

Abstract

Recent initiatives by the US ONCHIT highlight the need for electronic population health data collection relating to aspects of Public Health Case (PH Case) reporting and Adverse Event (AE) reporting. Proposed solutions to date have been primarily provider-based, limited by organization-wide startup & maintenance costs, and hampered by risk-averse data distribution policies. Little attention has been given to consumer-focused, distributed data collection models, where objective, consumer-provided standardized data can be used prior to case identification to facilitate earlier use of extensible and distributed information networks in biosurveillance. We propose here one promising model for pre-case biosurveillance management, employing the use of breath-based, multiple array sensing and data capture. The conceptual applications employed in this technology set are provided by way of illustration, and may also serve as a transformative model for emerging EMR/EHR requirements.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20703924     DOI: 10.1007/s10916-009-9283-8

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  5 in total

1.  Detection of lung cancer by sensor array analyses of exhaled breath.

Authors:  Roberto F Machado; Daniel Laskowski; Olivia Deffenderfer; Timothy Burch; Shuo Zheng; Peter J Mazzone; Tarek Mekhail; Constance Jennings; James K Stoller; Jacqueline Pyle; Jennifer Duncan; Raed A Dweik; Serpil C Erzurum
Journal:  Am J Respir Crit Care Med       Date:  2005-03-04       Impact factor: 21.405

2.  Breath ammonia testing for diagnosis of hepatic encephalopathy.

Authors:  Suja DuBois; Sue Eng; Renuka Bhattacharya; Steve Rulyak; Todd Hubbard; David Putnam; David J Kearney
Journal:  Dig Dis Sci       Date:  2005-10       Impact factor: 3.199

3.  Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array.

Authors:  Peter J Mazzone; Jeffrey Hammel; Raed Dweik; Jie Na; Carmen Czich; Daniel Laskowski; Tarek Mekhail
Journal:  Thorax       Date:  2007-02-27       Impact factor: 9.139

4.  A new portable sulfide monitor with a zinc-oxide semiconductor sensor for daily use and field study.

Authors:  Naoko Tanda; Jumpei Washio; Kyoko Ikawa; Kengo Suzuki; Takeyoshi Koseki; Masaki Iwakura
Journal:  J Dent       Date:  2007-05-07       Impact factor: 4.379

5.  Measurement of ammonia in human breath with a liquid-film conductivity sensor.

Authors:  Kei Toda; Jianzhong Li; Purnendu K Dasgupta
Journal:  Anal Chem       Date:  2006-10-15       Impact factor: 6.986

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.