Literature DB >> 17036301

Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI.

Geoff J M Parker1, Caleb Roberts, Andrew Macdonald, Giovanni A Buonaccorsi, Sue Cheung, David L Buckley, Alan Jackson, Yvonne Watson, Karen Davies, Gordon C Jayson.   

Abstract

Rapid T(1)-weighted 3D spoiled gradient-echo (GRE) data sets were acquired in the abdomen of 23 cancer patients during a total of 113 separate visits to allow dynamic contrast-enhanced MRI (DCE-MRI) analysis of tumor microvasculature. The arterial input function (AIF) was measured in each patient at each visit using an automated AIF extraction method following a standardized bolus administration of gadodiamide. The AIFs for each patient were combined to obtain a mean AIF that is representative for any individual. The functional form of this general AIF may be useful for studies in which AIF measurements are not possible. Improvements in the reproducibility of DCE-MRI model parameters (K(trans), v(e), and v(p)) were observed when this new, high-temporal-resolution population AIF was used, indicating the potential for increased sensitivity to therapy-induced change. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17036301     DOI: 10.1002/mrm.21066

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  232 in total

Review 1.  Dynamic contrast-enhanced imaging techniques: CT and MRI.

Authors:  J P B O'Connor; P S Tofts; K A Miles; L M Parkes; G Thompson; A Jackson
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Permeability assessment of the focused ultrasound-induced blood-brain barrier opening using dynamic contrast-enhanced MRI.

Authors:  F Vlachos; Y-S Tung; E E Konofagou
Journal:  Phys Med Biol       Date:  2010-08-25       Impact factor: 3.609

3.  Combined prostate diffusion tensor imaging and dynamic contrast enhanced MRI at 3T--quantitative correlation with biopsy.

Authors:  Piotr Kozlowski; Silvia D Chang; Ran Meng; Burkhard Mädler; Robert Bell; Edward C Jones; S Larry Goldenberg
Journal:  Magn Reson Imaging       Date:  2010-04-13       Impact factor: 2.546

4.  Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

Authors:  Federico D Pineda; Ty O Easley; Gregory S Karczmar
Journal:  Med Phys       Date:  2018-01-24       Impact factor: 4.071

Review 5.  Dynamic contrast-enhanced magnetic resonance imaging and pharmacokinetic models in prostate cancer.

Authors:  Tobias Franiel; Bernd Hamm; Hedvig Hricak
Journal:  Eur Radiol       Date:  2010-12-24       Impact factor: 5.315

6.  In vitro Gd-DTPA relaxometry studies in oxygenated venous human blood and aqueous solution at 3 and 7 T.

Authors:  Chaitanya Kalavagunta; Shalom Michaeli; Gregory J Metzger
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

7.  A comparison of individual and population-derived vascular input functions for quantitative DCE-MRI in rats.

Authors:  David A Hormuth; Jack T Skinner; Mark D Does; Thomas E Yankeelov
Journal:  Magn Reson Imaging       Date:  2014-01-07       Impact factor: 2.546

8.  A novel anthropomorphic flow phantom for the quantitative evaluation of prostate DCE-MRI acquisition techniques.

Authors:  Silvin P Knight; Jacinta E Browne; James F Meaney; David S Smith; Andrew J Fagan
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

9.  Dynamic contrast-enhanced MRI perfusion quantification in hepatocellular carcinoma: comparison of gadoxetate disodium and gadobenate dimeglumine.

Authors:  Daniel Stocker; Stefanie Hectors; Octavia Bane; Naik Vietti-Violi; Daniela Said; Paul Kennedy; Jordan Cuevas; Guilherme M Cunha; Claude B Sirlin; Kathryn J Fowler; Sara Lewis; Bachir Taouli
Journal:  Eur Radiol       Date:  2021-05-27       Impact factor: 5.315

10.  A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution.

Authors:  Julio Cárdenas-Rodríguez; Christine M Howison; Mark D Pagel
Journal:  Magn Reson Imaging       Date:  2012-12-08       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.