Literature DB >> 17032115

Histologic evaluation of implants following flapless and flapped surgery: a study in canines.

William Becker1, Ulf M E Wikesjö, Lars Sennerby, Mohammed Qahash, Philippe Hujoel, Moshe Goldstein, Ilser Turkyilmaz.   

Abstract

BACKGROUND: Flapless surgery requires penetration of the alveolar mucosa and bone without reflection of mucoperiosteal flaps. Do these techniques force gingival tissue or foreign materials into osteotomies? If so, do such tissues or materials interfere with osseointegration? A proof-of-principle study using a canine model attempted to answer these questions.
METHODS: Five young adult Hound Labrador mongrel dogs received implants with a moderately roughened surface by anodic oxidation using flapless or conventional one-stage (control) surgery in contralateral jaw quadrants. The implants were placed into the osteotomies, and the international stability quotient (ISQ) was recorded using resonance frequency analysis. These measurements were repeated following a 3-month healing interval when the animals were euthanized, and implants and surrounding tissues were retrieved and processed for histologic analysis.
RESULTS: The implants were stable upon insertion and demonstrated increased stability at 3 months without significant differences between surgical protocols. The histologic evaluation showed high bone-implant contact (flapless surgery: 54.7% +/- 8.4%; control: 52.2% +/- 13.0%; P >0.05) without evidence of gingival tissue or foreign body inclusions. There were no significant differences in marginal bone levels between the surgical protocols. Post-insertion and at 3 months, ISQ values depended on the amount of torque delivered. Immediately post-insertion, for every 1-unit increase in torque value, the ISQ increased by 0.3 (95% confidence interval: 0.1 to 0.4; P = 0.0043). Three months postoperatively, for every one-unit increase in torque the ISQ value decreased 0.2 (95% confidence interval: -0.4 to -0.1; P = 0.0012). The effect of torque on ISQ values was independent of treatment effects and remained significant after adjustment for treatment.
CONCLUSIONS: The results suggest that implants placed without flap reflection remain stable and exhibit clinically relevant osseointegration similar to when implants are placed with flapped procedures. Greater torque at implant placement resulted in less implant stability at 3 months.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17032115     DOI: 10.1902/jop.2006.060090

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  8 in total

Review 1.  Efficacy of different surgical techniques for peri-implant tissue preservation in immediate implant placement: a systematic review and meta-analysis.

Authors:  Sara Bakkali; María Rizo-Gorrita; Manuel-María Romero-Ruiz; José Luis Gutiérrez-Pérez; Daniel Torres-Lagares; Maria Ángeles Serrera-Figallo
Journal:  Clin Oral Investig       Date:  2021-01-29       Impact factor: 3.573

2.  Computer-aided flapless implant surgery and immediate loading. A technical note.

Authors:  Alfonso Baruffaldi; Pier Paolo Poli; Andrea Baruffaldi; Lorenzo Giberti; Maurizio Pigozzo; Carlo Maiorana
Journal:  Oral Maxillofac Surg       Date:  2016-04-05

Review 3.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

4.  MIDAS (Minimally Invasive Drilling And Styptic) protocol - A modified approach to treating patients under therapeutic anticoagulants.

Authors:  Yazad Gandhi; Neel Bhatavdekar
Journal:  J Oral Biol Craniofac Res       Date:  2019-04-30

5.  The efficacy of flapless implant surgery on soft-tissue profile comparing immediate loading implants to delayed loading implants: A comparative clinical study.

Authors:  Deepak Moses Ravindran; Uma Sudhakar; T Ramakrishnan; N Ambalavanan
Journal:  J Indian Soc Periodontol       Date:  2010-10

6.  The Effect of Flapless and Full-thickness Flap Techniques on Implant Stability During the Healing Period.

Authors:  Mohammed Jasim Al-Juboori; Shafluzan Bin AbdulRahaman
Journal:  Open Dent J       Date:  2015-07-31

7.  A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template.

Authors:  Shin-Young Youk; Jee-Ho Lee; Ji-Man Park; Seong-Joo Heo; Hyun-Ki Roh; Eun-Jin Park; Im Hee Shin
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

8.  An in-office, cost effective technique for measuring width of bone using intra-oral periapical radiographs in occlusal projection.

Authors:  Shrikar R Desai; I Karthikeyan; Rika Singh
Journal:  J Indian Soc Periodontol       Date:  2013-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.