Literature DB >> 17027234

Resonance frequency measurements of implant stability in the dog mandible: experimental comparison with histomorphometric data.

H Schliephake1, A Sewing, A Aref.   

Abstract

The aim of the present study was to test the hypothesis that measurements of implant stability using resonance frequency analysis (RFA) correlate with histomorphometric data of bone anchorage. Ten adult female foxhounds received a total of 80 implants in their mandibles 3 months after removal of all premolar teeth. At the time of implant placement, torque required for bone tapping was registered as a measure of bone density and immediately after placement implant stability was assessed using RFA. RFA measurements were repeated at the time of implant retrieval after 1 month (5 dogs) and 3 months (5 dogs). Peri-implant bone regeneration was assessed histomorphometrically by measuring bone-implant contact (BIC) and the volume density of the newly formed peri-implant bone (BVD). RFA values at the time of implant placement did not correlate with the torque required to tap the bone for implant placement. After 1 and 3 months, RFA values were significantly increased compared with baseline values. BIC and BVD, however, had increased significantly during this interval. There was no correlation between bone-implant contact and RFA values nor between peri-implant bone density and RFA values. Thus, the hypothesis could not be verified. It is concluded that the validity of the individual measurement of implant stability using RFA should be considered with caution.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17027234     DOI: 10.1016/j.ijom.2006.05.002

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  7 in total

1.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

2.  The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia.

Authors:  In-Phill Park; Seong-Kyun Kim; Shin-Jae Lee; Joo-Hee Lee
Journal:  J Adv Prosthodont       Date:  2011-06-30       Impact factor: 1.904

3.  In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material.

Authors:  Mu-Seung Kwak; Seok-Gyu Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

4.  Influence of a Novel Surface of Bioactive Implants on Osseointegration: A Comparative and Histomorfometric Correlation and Implant Stability Study in Minipigs.

Authors:  Manuel M Romero-Ruiz; Francisco Javier Gil-Mur; José Vicente Ríos-Santos; Pedro Lázaro-Calvo; Blanca Ríos-Carrasco; Mariano Herrero-Climent
Journal:  Int J Mol Sci       Date:  2019-05-09       Impact factor: 5.923

5.  The Bone Buttress Theory: The Effect of the Mechanical Loading of Bone on the Osseointegration of Dental Implants.

Authors:  David Chavarri-Prado; Aritza Brizuela-Velasco; Ángel Álvarez-Arenal; Markel Dieguez-Pereira; Esteban Pérez-Pevida; Iratxe Viteri-Agustín; Alejandro Estrada-Martínez
Journal:  Biology (Basel)       Date:  2020-12-28

6.  Resonance frequency analysis of implants placed in condensed bone.

Authors:  Balazs Feher; Florian Frommlet; Reinhard Gruber; Lena Hirtler; Christian Ulm; Ulrike Kuchler
Journal:  Clin Oral Implants Res       Date:  2021-09-01       Impact factor: 5.021

7.  Fibronectin-Grafted Titanium Dental Implants: An In Vivo Study.

Authors:  Yu-Chi Chang; Kuo-Ning Ho; Sheng-Wei Feng; Haw-Ming Huang; Chia-Hsun Chang; Che-Tong Lin; Nai-Chia Teng; Yu Hwa Pan; Wei-Jen Chang
Journal:  Biomed Res Int       Date:  2016-06-06       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.