Literature DB >> 1701892

Endocardial pacing in infants and children 15 kg or less in weight: medium-term follow-up.

J A Till1, S Jones, E Rowland, E A Shinebourne, D E Ward.   

Abstract

Twenty-four children 15 kg or less in weight (range 2.8-15 kg) underwent implantation of a permanent pacemaker using the transvenous technique of lead placement. During a follow-up period of 2 months to 6 years 1 month (median 3 years 6 months) eight children suffered complications, six of which necessitated reoperation. These included: lead fracture in two, infection in two, transient myocardial dysfunction in one, generator migration in one, premature battery depletion in one, and threshold rise in one. A loop of redundant ventricular lead positioned in the atrium at the time of implant is successfully unravelling in all children. One child died during the follow-up period of a pneumonia unrelated to her pacemaker. The other children are growing and developing normally and the cosmetic appearance has proved acceptable in all cases.

Entities:  

Mesh:

Year:  1990        PMID: 1701892     DOI: 10.1111/j.1540-8159.1990.tb04013.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  6 in total

1.  Implantable diagnostic and therapeutic devices in children.

Authors:  T-N Le; S C Gouw; T M Hoorntje; N Sreeram
Journal:  Neth Heart J       Date:  2002-11       Impact factor: 2.380

2.  An alternate technique to pacing in complex congenital heart disease: assessment of the left thoracotomy approach.

Authors:  Ashley D Roberts; Suvro Sett; Jacques Leblanc; Shubhayan Sanatani
Journal:  Can J Cardiol       Date:  2006-05-01       Impact factor: 5.223

3.  Comparison of modern steroid-eluting epicardial and thin transvenous pacemaker leads in pediatric and congenital heart disease patients.

Authors:  Elizabeth B Fortescue; Charles I Berul; Frank Cecchin; Edward P Walsh; John K Triedman; Mark E Alexander
Journal:  J Interv Card Electrophysiol       Date:  2005-10       Impact factor: 1.900

4.  Endocardial and epicardial steroid lead pacing in the neonatal and paediatric age group.

Authors:  F Udink ten Cate; J Breur; N Boramanand; J Crosson; A Friedman; J Brenner; E Meijboom; N Sreeram
Journal:  Heart       Date:  2002-10       Impact factor: 5.994

5.  Twiddler's syndrome in children: an unusual cause of pacemaker failure.

Authors:  S Abrams; I Peart
Journal:  Br Heart J       Date:  1995-02

6.  Endocardial pacemaker implantation in neonates and infants.

Authors:  Canan Ayabakan; Eric Rosenthal
Journal:  Indian Pacing Electrophysiol J       Date:  2006-04-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.