Literature DB >> 25696046

Implantable diagnostic and therapeutic devices in children.

T-N Le, S C Gouw, T M Hoorntje, N Sreeram.   

Abstract

Many advances have been made in the use of implantable diagnostic and therapeutic devices in adults. In children the indications for and diagnostic and therapeutic value of these devices still have to be determined. Our aim is to provide an overview of the clinical use of diagnostic and therapeutic devices in children. The role of implantable loop recorders (ILR), the feasibility and safety of transvenous pacing in neonates, the value of permanent pacing in children with recurrent syncope or reflex anoxic seizures and the role of implantable cardioverter defibrillator devices are highlighted with relevant case histories.

Entities:  

Keywords:  children; implantable devices; paediatrics

Year:  2002        PMID: 25696046      PMCID: PMC2499809     

Source DB:  PubMed          Journal:  Neth Heart J        ISSN: 1568-5888            Impact factor:   2.380


  10 in total

1.  Permanent cardiac pacing for reflex anoxic seizure.

Authors:  N Sreeram; W Whitehouse
Journal:  Arch Dis Child       Date:  1996-11       Impact factor: 3.791

2.  The North American Vasovagal Pacemaker Study (VPS). A randomized trial of permanent cardiac pacing for the prevention of vasovagal syncope.

Authors:  S J Connolly; R Sheldon; R S Roberts; M Gent
Journal:  J Am Coll Cardiol       Date:  1999-01       Impact factor: 24.094

3.  Pediatric transvenous pacing: a concern for venous thrombosis?

Authors:  P C Gillette; V Zeigler; G B Bradham; P Kinsella
Journal:  Pacing Clin Electrophysiol       Date:  1988-11       Impact factor: 1.976

4.  Breathholding spells (cyanotic and pallid infantile syncope).

Authors:  C T Lombroso; P Lerman
Journal:  Pediatrics       Date:  1967-04       Impact factor: 7.124

5.  Cardiac pacing for severe childhood neurally mediated syncope with reflex anoxic seizures.

Authors:  K A McLeod; N Wilson; J Hewitt; J Norrie; J B Stephenson
Journal:  Heart       Date:  1999-12       Impact factor: 5.994

6.  [Implantable ECG recorder revealed the diagnosis in a baby with apparent life-threatening events].

Authors:  T M Hoorntje; W Langerak; H E Blokland-Loggers; N Sreeram
Journal:  Ned Tijdschr Geneeskd       Date:  1999-09-25

7.  Endocardial pacing in infants and children 15 kg or less in weight: medium-term follow-up.

Authors:  J A Till; S Jones; E Rowland; E A Shinebourne; D E Ward
Journal:  Pacing Clin Electrophysiol       Date:  1990-11       Impact factor: 1.976

8.  Implantable cardioverter-defibrillators in children: a single-institutional experience.

Authors:  W R Wilson; G E Greer; B P Grubb
Journal:  Ann Thorac Surg       Date:  1998-03       Impact factor: 4.330

9.  Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society.

Authors:  M J Silka; J Kron; A Dunnigan; M Dick
Journal:  Circulation       Date:  1993-03       Impact factor: 29.690

10.  Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators.

Authors:  A D Krahn; G J Klein; R Yee; T Takle-Newhouse; C Norris
Journal:  Circulation       Date:  1999-01-26       Impact factor: 29.690

  10 in total