Literature DB >> 17012436

Orientation of the acetabular component. A comparison of five navigation systems with conventional surgical technique.

M Honl1, K Schwieger, M Salineros, J Jacobs, M Morlock, M Wimmer.   

Abstract

We compared the orientation of the acetabular component obtained by a conventional manual technique with that using five different navigation systems. Three surgeons carried out five implantations of an acetabular component with each navigation system, as well as manually, using an anatomical model. The orientation of the acetabular component, including inclination and anteversion, and its position was determined using a co-ordinate measuring machine. The variation of the orientation of the acetabular component was higher in the conventional group compared with the navigated group. One experienced surgeon took significantly less time for the procedure. However, his placement of the component was no better than that of the less experienced surgeons. Significantly better inclination and anteversion (p < 0.001 for both) were obtained using navigation. These parameters were not significantly different between the surgeons when using the conventional technique (p = 0.966). The use of computer navigation helps a surgeon to orientate the acetabular component with less variation regarding inclination and anteversion.

Mesh:

Year:  2006        PMID: 17012436     DOI: 10.1302/0301-620X.88B10.17587

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  17 in total

1.  Can an Augmented Reality Headset Improve Accuracy of Acetabular Cup Orientation in Simulated THA? A Randomized Trial.

Authors:  Kartik Logishetty; Luke Western; Ruairidh Morgan; Farhad Iranpour; Justin P Cobb; Edouard Auvinet
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

2.  Navigated non-image-based positioning of the acetabulum during total hip replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri; Jean-Claude Dosch; Marius Uscatu; Eugen Ciobanu
Journal:  Int Orthop       Date:  2007-11-13       Impact factor: 3.075

3.  Six sigma analysis of minimally invasive acetabular arthroplasty: a preliminary investigation.

Authors:  David A Heck; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2009-05-22       Impact factor: 4.176

4.  Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment.

Authors:  Alberto Carli; Ahmed Aoude; Avishai Reuven; Bogdan Matache; John Antoniou; David J Zukor
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

Review 5.  Evidence-based computer-navigated total hip arthroplasty: an updated analysis of randomized controlled trials.

Authors:  Yu-Lin Li; Jun Jia; Qiang Wu; Guang-Zhi Ning; Qiu-Li Wu; Shi-Qing Feng
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-04-16

6.  Intraoperative navigation for accurate midline placement of anterior lumbar interbody fusion and total disc replacement prosthesis.

Authors:  Kevin Phan; Joshua Xu; Monish M Maharaj; Ralph J Mobbs
Journal:  J Spine Surg       Date:  2017-06

7.  A novel non-invasive mechanical technique of cup and stem placement and leg length adjustment in total hip arthroplasty for dysplastic hips.

Authors:  Takashi Murayama; Hideo Ohnishi; Toshiharu Mori; Yuichi Okazaki; Kenji Sujita; Akinori Sakai
Journal:  Int Orthop       Date:  2014-12-09       Impact factor: 3.075

8.  Changes of center of rotation and femoral offset in total hip arthroplasty.

Authors:  Jon A Bjarnason; Olav Reikeras
Journal:  Ann Transl Med       Date:  2015-12

9.  Validation of the femoral anteversion measurement method used in imageless navigation.

Authors:  Glen A Turley; Shahbaz M Y Ahmed; Mark A Williams; Damian R Griffin
Journal:  Comput Aided Surg       Date:  2012-06-08

Review 10.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.