Literature DB >> 17011214

An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data.

Roel H R Deckers1, Peter van Gelderen, Mario Ries, Olivier Barret, Jeff H Duyn, Vasiliki N Ikonomidou, Masaki Fukunaga, Gary H Glover, Jacco A de Zwart.   

Abstract

The quality of MRI time series data, which allows the study of dynamic processes, is often affected by confounding sources of signal fluctuation, including the cardiac and respiratory cycle. An adaptive filter is described, reducing these signal fluctuations as long as they are repetitive and their timing is known. The filter, applied in image domain, does not require temporal oversampling of the artifact-related fluctuations. Performance is demonstrated for suppression of cardiac and respiratory artifacts in 10-minute brain scans on 6 normal volunteers. Experimental parameters resemble a typical fMRI experiment (17 slices; 1700 ms TR). A second dataset was acquired at a rate well above the Nyquist frequency for both cardiac and respiratory cycle (single slice; 100 ms TR), allowing identification of artifacts specific to the cardiac and respiratory cycles, aiding assessment of filtering performance. Results show significant reduction in temporal standard deviation (SD(t)) in all subjects. For all 6 datasets with 1700 ms TR combined, the filtering method resulted in an average reduction in SD(t) of 9.2% in 2046 voxels substantially affected by respiratory artifacts, and 12.5% for the 864 voxels containing substantial cardiac artifacts. The maximal SD(t) reduction achieved was 52.7% for respiratory and 55.3% for cardiac filtering. Performance was found to be at least equivalent to the previously published RETROICOR method. Furthermore, the interaction between the filter and fMRI activity detection was investigated using Monte Carlo simulations, demonstrating that filtering algorithms introduce a systematic error in the detected BOLD-related signal change if applied sequentially. It is demonstrated that this can be overcome by combining physiological artifact filtering and detection of BOLD-related signal changes simultaneously. Visual fMRI data from 6 volunteers were analyzed with and without the filter proposed here. Inclusion of the cardio-respiratory regressors in the design matrix yielded a 4.6% t-score increase and 4.0% increase in the number of significantly activated voxels.

Entities:  

Mesh:

Year:  2006        PMID: 17011214      PMCID: PMC1716734          DOI: 10.1016/j.neuroimage.2006.08.006

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  18 in total

1.  Localization of cardiac-induced signal change in fMRI.

Authors:  M S Dagli; J E Ingeholm; J V Haxby
Journal:  Neuroimage       Date:  1999-04       Impact factor: 6.556

2.  On the origin of respiratory artifacts in BOLD-EPI of the human brain.

Authors:  Christian Windischberger; Herbert Langenberger; Thomas Sycha; Edda M Tschernko; Gabriele Fuchsjäger-Mayerl; Leopold Schmetterer; Ewald Moser
Journal:  Magn Reson Imaging       Date:  2002-10       Impact factor: 2.546

3.  Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter van Gelderen; Jerzy Bodurka; Renxin Chu; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Scalable multichannel MRI data acquisition system.

Authors:  Jerzy Bodurka; Patrick J Ledden; Peter van Gelderen; Renxin Chu; Jacco A de Zwart; Doug Morris; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

5.  Selective averaging of rapidly presented individual trials using fMRI.

Authors:  A M Dale; R L Buckner
Journal:  Hum Brain Mapp       Date:  1997       Impact factor: 5.038

6.  Reduction of physiological fluctuations in fMRI using digital filters.

Authors:  B Biswal; E A DeYoe; J S Hyde
Journal:  Magn Reson Med       Date:  1996-01       Impact factor: 4.668

7.  Noise suppression digital filter for functional magnetic resonance imaging based on image reference data.

Authors:  M H Buonocore; R J Maddock
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

8.  Retrospective estimation and correction of physiological fluctuation in functional MRI.

Authors:  X Hu; T H Le; T Parrish; P Erhard
Journal:  Magn Reson Med       Date:  1995-08       Impact factor: 4.668

9.  A precise and fast temperature mapping using water proton chemical shift.

Authors:  Y Ishihara; A Calderon; H Watanabe; K Okamoto; Y Suzuki; K Kuroda; Y Suzuki
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

10.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging.

Authors:  S Ogawa; D W Tank; R Menon; J M Ellermann; S G Kim; H Merkle; K Ugurbil
Journal:  Proc Natl Acad Sci U S A       Date:  1992-07-01       Impact factor: 11.205

View more
  29 in total

Review 1.  A brief history of the resting state: the Washington University perspective.

Authors:  Abraham Z Snyder; Marcus E Raichle
Journal:  Neuroimage       Date:  2012-01-12       Impact factor: 6.556

2.  Dynamic retrospective filtering of physiological noise in BOLD fMRI: DRIFTER.

Authors:  Simo Särkkä; Arno Solin; Aapo Nummenmaa; Aki Vehtari; Toni Auranen; Simo Vanni; Fa-Hsuan Lin
Journal:  Neuroimage       Date:  2012-01-18       Impact factor: 6.556

3.  Physiological noise reduction using volumetric functional magnetic resonance inverse imaging.

Authors:  Fa-Hsuan Lin; Aapo Nummenmaa; Thomas Witzel; Jonathan R Polimeni; Thomas A Zeffiro; Fu-Nien Wang; John W Belliveau
Journal:  Hum Brain Mapp       Date:  2011-09-23       Impact factor: 5.038

Review 4.  Ultrafast inverse imaging techniques for fMRI.

Authors:  Fa-Hsuan Lin; Kevin W K Tsai; Ying-Hua Chu; Thomas Witzel; Aapo Nummenmaa; Tommi Raij; Jyrki Ahveninen; Wen-Jui Kuo; John W Belliveau
Journal:  Neuroimage       Date:  2012-01-21       Impact factor: 6.556

5.  Integration of motion correction and physiological noise regression in fMRI.

Authors:  Tyler B Jones; Peter A Bandettini; Rasmus M Birn
Journal:  Neuroimage       Date:  2008-05-21       Impact factor: 6.556

6.  The power of spectral density analysis for mapping endogenous BOLD signal fluctuations.

Authors:  Eugene P Duff; Leigh A Johnston; Jinhu Xiong; Peter T Fox; Iven Mareels; Gary F Egan
Journal:  Hum Brain Mapp       Date:  2008-07       Impact factor: 5.038

7.  Reducing correlated noise in fMRI data.

Authors:  Jacco A de Zwart; Peter van Gelderen; Masaki Fukunaga; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

8.  A kernel machine-based fMRI physiological noise removal method.

Authors:  Xiaomu Song; Nan-kuei Chen; Pooja Gaur
Journal:  Magn Reson Imaging       Date:  2013-10-19       Impact factor: 2.546

9.  Influence of heart rate on the BOLD signal: the cardiac response function.

Authors:  Catie Chang; John P Cunningham; Gary H Glover
Journal:  Neuroimage       Date:  2008-10-07       Impact factor: 6.556

10.  A cerebrovascular response model for functional neuroimaging including dynamic cerebral autoregulation.

Authors:  Solomon Gilbert Diamond; Katherine L Perdue; David A Boas
Journal:  Math Biosci       Date:  2009-05-13       Impact factor: 2.144

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.