Integration of motion correction and physiological noise regression in fMRI.

Tyler B Jones1, Peter A Bandettini, Rasmus M Birn.   

Abstract

Physiological fluctuations resulting from the heart beat and respiration are a dominant source of noise in fMRI, particularly at high field strengths. Commonly used physiological noise correction techniques, such as RETROspective Image CORrection (RETROICOR), rely critically on the timing of the image acquisition relative to the heart beat, but do not account for the effects of subject motion. Such motion affects the fluctuation amplitude, yet volume registration can distort the timing information. In this study, we aimed to systematically determine the optimal order of volume registration, slice-time correction and RETROICOR in their traditional forms. In addition, we evaluate the sensitivity of RETROICOR to timing errors introduced by the slice acquisition, and we develop a new method of accounting for timing errors introduced by volume registration into physiological correction (motion-modified RETROICOR). Both simulation and resting data indicate that the temporal standard deviation is reduced most by performing volume registration before RETROICOR and slice-time correction after RETROCIOR. While simulations indicate that physiological noise correction with regressors constructed on a slice-by-slice basis more accurately modeled physiological noise compared to using the same regressors for the entire volume, the difference between these regression techniques in subject data was minimal. The motion-modified RETROICOR showed marked improvement in simulations with varying amounts of subject motion, reducing the temporal standard deviation by up to 36% over the traditional RETROICOR. Though to a lesser degree than in simulation, the motion-modified RETROICOR performed better in nearly every voxel in the brain in both high- and low-resolution subject data.

Mesh:

Year:  2008        PMID: 18583155      PMCID: PMC2833099          DOI: 10.1016/j.neuroimage.2008.05.019

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  24 in total

1.  Localization of cardiac-induced signal change in fMRI.

Authors:  M S Dagli; J E Ingeholm; J V Haxby
Journal:  Neuroimage       Date:  1999-04       Impact factor: 6.556

2.  Motion correction in fMRI via registration of individual slices into an anatomical volume.

Authors:  B Kim; J L Boes; P H Bland; T L Chenevert; C R Meyer
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

3.  Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals.

Authors:  Jong Yong A Foo; Stephen J Wilson; Carolyn Dakin; Gordon Williams; Margaret-Anne Harris; David Cooper
Journal:  Physiol Meas       Date:  2005-05-10       Impact factor: 2.833

4.  Non-white noise in fMRI: does modelling have an impact?

Authors:  Torben E Lund; Kristoffer H Madsen; Karam Sidaros; Wen-Lin Luo; Thomas E Nichols
Journal:  Neuroimage       Date:  2005-08-11       Impact factor: 6.556

5.  Prospective real-time slice-by-slice motion correction for fMRI in freely moving subjects.

Authors:  O Speck; J Hennig; M Zaitsev
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

6.  Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI.

Authors:  Rasmus M Birn; Jason B Diamond; Monica A Smith; Peter A Bandettini
Journal:  Neuroimage       Date:  2006-04-24       Impact factor: 6.556

7.  An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data.

Authors:  Roel H R Deckers; Peter van Gelderen; Mario Ries; Olivier Barret; Jeff H Duyn; Vasiliki N Ikonomidou; Masaki Fukunaga; Gary H Glover; Jacco A de Zwart
Journal:  Neuroimage       Date:  2006-09-29       Impact factor: 6.556

8.  Physiological noise modelling for spinal functional magnetic resonance imaging studies.

Authors:  Jonathan C W Brooks; Christian F Beckmann; Karla L Miller; Richard G Wise; Carlo A Porro; Irene Tracey; Mark Jenkinson
Journal:  Neuroimage       Date:  2007-09-20       Impact factor: 6.556

9.  AFNI: software for analysis and visualization of functional magnetic resonance neuroimages.

Authors:  R W Cox
Journal:  Comput Biomed Res       Date:  1996-06

10.  Functional connectivity in single and multislice echoplanar imaging using resting-state fluctuations.

Authors:  M J Lowe; B J Mock; J A Sorenson
Journal:  Neuroimage       Date:  1998-02       Impact factor: 6.556

View more
  30 in total

Review 1.  A brief history of the resting state: the Washington University perspective.

Authors:  Abraham Z Snyder; Marcus E Raichle
Journal:  Neuroimage       Date:  2012-01-12       Impact factor: 6.556

2.  Mapping sources of correlation in resting state FMRI, with artifact detection and removal.

Authors:  Hang Joon Jo; Ziad S Saad; W Kyle Simmons; Lydia A Milbury; Robert W Cox
Journal:  Neuroimage       Date:  2010-04-24       Impact factor: 6.556

Review 3.  Understanding variability in the BOLD signal and why it matters for aging.

Authors:  Cheryl L Grady; Douglas D Garrett
Journal:  Brain Imaging Behav       Date:  2014-06       Impact factor: 3.978

Review 4.  Bring the Noise: Reconceptualizing Spontaneous Neural Activity.

Authors:  Lucina Q Uddin
Journal:  Trends Cogn Sci       Date:  2020-06-27       Impact factor: 20.229

5.  Optimizing preprocessing and analysis pipelines for single-subject fMRI. I. Standard temporal motion and physiological noise correction methods.

Authors:  Nathan W Churchill; Anita Oder; Hervé Abdi; Fred Tam; Wayne Lee; Christopher Thomas; Jon E Ween; Simon J Graham; Stephen C Strother
Journal:  Hum Brain Mapp       Date:  2011-03-31       Impact factor: 5.038

6.  Evaluation of different cerebrospinal fluid and white matter fMRI filtering strategies-Quantifying noise removal and neural signal preservation.

Authors:  Marek Bartoň; Radek Mareček; Lenka Krajčovičová; Tomáš Slavíček; Tomáš Kašpárek; Petra Zemánková; Pavel Říha; Michal Mikl
Journal:  Hum Brain Mapp       Date:  2018-11-07       Impact factor: 5.038

7.  Modular preprocessing pipelines can reintroduce artifacts into fMRI data.

Authors:  Martin A Lindquist; Stephan Geuter; Tor D Wager; Brian S Caffo
Journal:  Hum Brain Mapp       Date:  2019-01-21       Impact factor: 5.038

8.  The influence of physiological noise correction on test-retest reliability of resting-state functional connectivity.

Authors:  Rasmus M Birn; Maria Daniela Cornejo; Erin K Molloy; Rémi Patriat; Timothy B Meier; Gregory R Kirk; Veena A Nair; M Elizabeth Meyerand; Vivek Prabhakaran
Journal:  Brain Connect       Date:  2014-09

9.  The impact of physiologic noise correction applied to functional MRI of pain at 1.5 and 3.0 T.

Authors:  Keith M Vogt; James W Ibinson; Petra Schmalbrock; Robert H Small
Journal:  Magn Reson Imaging       Date:  2011-05-14       Impact factor: 2.546

10.  Sensitivity of the resting-state haemodynamic response function estimation to autonomic nervous system fluctuations.

Authors:  Guo-Rong Wu; Daniele Marinazzo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-05-13       Impact factor: 4.226

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.