Literature DB >> 16998706

Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management.

Yoshimasa Sakamoto1, Kazuhiro Hashimoto, Hiroshi Okuyama, Shinichi Ishii, Taguchi Shingo, Hiroshi Kagawa.   

Abstract

Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.

Entities:  

Mesh:

Year:  2006        PMID: 16998706     DOI: 10.1007/s10047-006-0334-3

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  19 in total

1.  Acute thrombosis of prosthetic valves: a multivariate analysis of the risk factors for a lifethreatening event.

Authors:  A Renzulli; L De Luca; A Caruso; R Verde; D Galzerano; M Cotrufo
Journal:  Eur J Cardiothorac Surg       Date:  1992       Impact factor: 4.191

2.  [Case report of a malfunctioning SJM 19 A aortic valve prosthesis requiring reoperation].

Authors:  C Kikuchi; S Ishihara; Y Sugiyama; H Ishii
Journal:  Kyobu Geka       Date:  2001-03

3.  [Discrete subaortic stenosis after aortic valve replacement--a case report].

Authors:  K Iha; K Koja; Y Kuniyoshi; M Akasaki; K Miyagi; A Kusaba
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1994-07

4.  Thrombectomy of the Björk-Shiley prosthetic valve revisited: long-term results.

Authors:  C G Montero; N Mula; R Brugos; G Tellez; D Figuera
Journal:  Ann Thorac Surg       Date:  1989-12       Impact factor: 4.330

5.  Pannus formation in aortic valve prostheses in the late postoperative period.

Authors:  Yukio Kuniyoshi; Kageharu Koja; Kazufumi Miyagi; Mituyoshi Shimoji; Tooru Uezu; Katuya Arakaki; Satoshi Yamashiro; Katuhito Mabuni; Shigenobu Senaha; Yoshiyuki Nakasone
Journal:  J Artif Organs       Date:  2003       Impact factor: 1.731

6.  Thrombosis of the Björk-Shiley prosthesis: illustrative cases and review of the literature.

Authors:  J O Wright; L F Hiratzka; B Brandt; D B Doty
Journal:  J Thorac Cardiovasc Surg       Date:  1982-07       Impact factor: 5.209

7.  Reoperations for left-sided low-profile mechanical prosthetic obstructions.

Authors:  J Martinell; J Fraile; V Artiz; J Cortina; P Fresneda; G Rábago
Journal:  Ann Thorac Surg       Date:  1987-02       Impact factor: 4.330

8.  Fate of thrombectomized Björk-Shiley valves. A long-term cinefluoroscopic, echocardiographic, and hemodynamic evaluation.

Authors:  P Venugopal; U Kaul; K S Iyer; I M Rao; A Balram; B Das; A Sampathkumar; S Mukherjee; M Rajani; H S Wasir
Journal:  J Thorac Cardiovasc Surg       Date:  1986-02       Impact factor: 5.209

9.  Prosthetic valve obstruction: thrombolysis versus operation.

Authors:  N Vitale; A Renzulli; F Cerasuolo; A Caruso; M Festa; L de Luca; M Cotrufo
Journal:  Ann Thorac Surg       Date:  1994-02       Impact factor: 4.330

10.  Patch enlargement of the aortic valve ring by extending the aortic incision into the anterior mitral leaflet. New operative technique.

Authors:  S Manouguian; W Seybold-Epting
Journal:  J Thorac Cardiovasc Surg       Date:  1979-09       Impact factor: 5.209

View more
  15 in total

1.  Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients.

Authors:  Wei-Guo Ma; Bin Hou; Adiljan Abdurusul; Ding-Xu Gong; Yue Tang; Qian Chang; Jian-Ping Xu; Han-Song Sun
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

2.  Journal of Artificial Organs 2006: the year in review.

Authors:  Y Sawa; T Horiuchi; A Kishida; T Masuzawa; M Nishimura; E Tatsumi; Y Tomizawa; H Watanabe
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

3.  Rapid pannus formation after few months of obstructing aortic mechanical prosthesis.

Authors:  Bassel Al-Alao; Urszula Simoniuk; Brian Heron; Haralabos Parissis
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-09-25

4.  Aorta-atria-septum combined incision for aortic valve re-replacement.

Authors:  Yiwei Xu; Xiaofeng Ye; Zhaolong Li; Qiang Zhao
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

5.  Utility of cardiac computed tomography for evaluation of pannus in mechanical aortic valve.

Authors:  Young Joo Suh; Young Jin Kim; Sak Lee; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Byoung Wook Choi; Byung-Chul Chang
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-21       Impact factor: 2.357

Review 6.  Current status of right ventricular outflow tract reconstruction: complete translation of a review article originally published in Kyobu Geka 2014;67:65-77.

Authors:  Yusuke Yamamoto; Masaaki Yamagishi; Takako Miyazaki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-12-13

7.  Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard.

Authors:  I-Chen Tsai; Yung-Kai Lin; Yen Chang; Yun-Ching Fu; Chung-Chi Wang; Shih-Rong Hsieh; Hao-Ji Wei; Hung-Wen Tsai; Sheng-Ling Jan; Kuo-Yang Wang; Min-Chi Chen; Clayton Chi-Chang Chen
Journal:  Eur Radiol       Date:  2008-11-27       Impact factor: 5.315

8.  Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

Authors:  Ahmad K Darwazah
Journal:  J Cardiothorac Surg       Date:  2012-06-29       Impact factor: 1.637

9.  Early Doppler-echocardiography evaluation of Carpentier-Edwards Standard and Carpentier-Edwards Magna aortic prosthetic valve: comparison of hemodynamic performance.

Authors:  Giovanni Minardi; Giovanni Pulignano; Donatella Del Sindaco; Martina Sordi; Herribert Pavaci; Amedeo Pergolini; Giordano Zampi; Francesca Moschella Orsini; Carlo Gaudio; Francesco Musumeci
Journal:  Cardiovasc Ultrasound       Date:  2011-11-24       Impact factor: 2.062

10.  Rare early prosthesis obstruction after mitral valve replacement: a case report and literature review.

Authors:  Jun Shi; Zhi-xuan Bai; Jia Hu; Ben-gui Zhang; Ying-qiang Guo
Journal:  J Cardiothorac Surg       Date:  2012-07-02       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.